版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Foreword
ThiscodeisformulatedaccordingtotherequirementsofNoticeonArrangingthePlanofDevelopingStandardsforTelecommunicationEngineeringConstructionin2008(G.X.B.G.H.〔2008〕No.132)issuedbyformerministryofinformationindustry.
Requirementsonenergysavingofbuildings,telecommunicationequipmentandcorollaryequipmentforvarioustelecommunicationbureaus(stations)havebeenputforwardinthiscode.
Theprovision(s)inboldis(are)compulsoryone(ones)andmustbeenforcedstrictly.
ThetelecommunicationDevelopmentDivisionofMinistryofIndustryandInformationTechnologyisinchargeofinterpretingandimplementationsuperyisingofthiscode.PleasecontactTelecommunicationDevelopmentDivisionifyouwanttosupplementoramendthecontentsofthiscodeduringtheprocessofusage.PleaseposttherelevantopinionsforsupplementoramendmentTelecommunicationDevelopmentDivision(Address:No.13,WestChang'anStreet,Beijing,Postcode:100804).
ChiefEditorialOrganization:
ChinaInformationTechnologyDesigningandConsultingInstituteCo.,Ltd.
ChiefDraftingStaff:
LvWeiWangDiankuiLiHongxiaCuiHongyingZhaoKaiLiuWei
ZhangDekeGuLeiQiaoYueqiang
ParticipatingEditorialOrganization:
HuaxinConsultingCo.,Ltd.
ChinaMobileGroupDesignInstituteCo.,Ltd.
JiangsuPostsandTelecommunicationsPlanningandDesigningInstituteCo.,Ltd.
ChiefParticipatingStaff:
YeXiangyangSongFufengLuZhijun
Contents
1GeneralProvisions (1)
2RequirementsonEnergySavingofBuildings (2)
2.1GeneralLayoutofTelecommunicationCentres(Stations) (2)
2.2GeneralProvisionsonDesignforEnergySavingofTelecommunicationCentres(Stations) (2)
2.3RequirementsonDesignforEnergySavingofBuildingEnvelopesandMaterials (3)
2.4RequirementsonDesignforAirConditioningEnergySavingofTelecommunicationCentres(Stations) (4)
2.5RequirementsonDesignofElectricalEnergySavingforTelecommunicationCenires(Stations) (5)
3RequirementsonEnergySavingofTelecommunicationEquipment
andInstallationDesign (6)
3.1RequirementsonEnergySavingofTelecommunicationEquipment (6)
3.2RequirementsonEnergySavingforInstallationDesignofTelecommunicationEquipment (6)
4RequirementsonEnergySavingofPowerSupplyandDistributionSystems (8)
4.1GeneralRequiremens (8)
4.2RequirementsonSelectionandConfigurafionofEquipment (8)
4.3SelectionandLayingofConductors (9)
4.4AplicationofRenewableEnergySources (9)
AppendixAExplanationsonWordingofThisCode (11)
ExplanationofProvisions (13)
·1·
1GeneralProvisions
1.0.1Thiscodeisapplicabletothedesignforenergysavingofnewlybuilttelecommunicationcentres(stations),andmaybereferredandexecutedfortherenovationandextensionoftelecommunicationcentres(stations).
1.0.2Threemainaspectsonthedesignforenergysavingoftelecommunicationcentres(stations),i.e.,energysavingforbuildings,telecommunicationequipmentandcorollaryequipment,shallbetakenintoconsideration.
1.0.3Measuresandsolutionsforenergysavingadoptedinthedesignforenergysavingshallnotreducethesafetyonoperationoftelecommunicationsystems.
1.0.4Theenergysavingdesignshalladjustmeasurestolocalconditions,attaintheadvancedtechnology,reasonableeconomic,safetyandserviceability.Therenovationandextensionengineeringshallfullyconsiderthefeaturesofexistingtelecommunicationcentres(stations),userationallytheexistingbuildings,equipment,takeactivelythereformationmeasuresandstrivetoreachthegoalofadvancement,serviceabilityandeconomy.
1.0.5Incasewherethiscodeconflictswithrelevantnationalstandardsandcodes,nationalstandardsandcodesshallprevail.Ifitisdifficulttoimplementindividualprovisionsofthiscode,sufficientreasonsshallbegiveninthedesign,whichshallbeapprovedbycompetentauthorities.Incasewhererelevanttechnicalrequirementsofotherstandardsandcodesfortelecommunicationindustryconflictwiththiscode,thiscodeshallprevail.
·2·
2RequirementsonEnergySavingofBuildings
2.1GeneralLayoutofTelecommunicationCentres(Stations)
2.1.1Siteselectionoftelecommunicationcentres(stations)shallmeettherequirementsofCodeforDesignofTelecommunicationPrivatePremiseYD/T5003-2005.
2.1.2Generallayoutanddesignoftelecommunicationcentres(stations)shouldtakefulluseofsunlightinwinterandnaturalventilationinsummerandavoidprevailingwinddirectioninwinter.Theoptimalorientationortheapproximatebestorientationatthisareashouldbeselectedasthemainorientation,soastoavoidthemaximumsunlightorientationinsummer.
2.2GeneralProvisionsonDesignforEnergySavingofTelecommunicationCentres(Stations)
2.2.1Thethermalperformanceforbuildingenvelopesoftelecommunicationcentres(stations)shallmeetrelevantrequirementsasstipulatedinArticle4.2.2ofDesignStandardforEnergyEfficiencyofPublicBuildingsGB50189-2005.
2.2.2Thedesignoftelecommunicationcentres(stations)shallcontroltheshapecoefficient.Theshapecoefficientshouldnotbetoobig.Theshapecoefficientoftelecommunicationcentres(stations)inseverecoldorcoldregionsshallbelessorequalto0.40.
2.2.3Thearearatioofwindowtowallfortelecommunicationcentres(stations)atdifferentorientationshallmeettherequirementsofDesignStandardforEnergyEfficiencyofPublicBuildingsGB50189-2005.
2.2.4Telecommunicationcentres(stations)shallnotbeequippedwithlargeareaofcurtainwallsmadeofglass(orothertransparentmaterials).
2.2.5Wholeyearunattendedequipmentroomsshallnotbeequippedwithexternalwindows.
2.2.6Fortelecommunicationcentres(stations)builtinareasofhotsummerandwarmwinterorhotsummerandcoldwinterandthosebuiltincoldregionswithhighcoolingload,externalwindowsshouldhavesunshadesoutside.TheshadingcoefficientshallmeettherequirementsofDesignStandardforEnergyEfficiencyofPublicBuildingsGB50189-2005.
2.2.7Telecommunicationcentres(stations)inseverecoldorcoldregionsshallnothaveopentypestaircasesandopentypeoutercorridor.
2.2.8Outerdoorsoftelecommunicationcentres(stations)shalladoptthemeasuresofheatinsulationandenergysaving.Theouterdooroftelecommunicationcentres(stations)inseverecoldregionsshallbeequippedwithfoyers;andthoseoftelecommunicationcentres(stations)incoldregionsshallbeequippedwithfoyers,andifthefoyersarenotequippedwith,themeasurestoreducecoldairinfiltrationshallbetaken.
2.2.9Theopeningsandholesthatcablesandpipelinesoftelecommunicationcentres(stations)passthroughbuildingenvelopeshallbesealedtightlybyfirestoppingmaterialsofequivalentfireenduranceaccordingtorequirementsofTechnicalSpecificationforApplicationofFireStoppinginBuildingsCECS154:2003.
2.2.10Theinternalsurfacetemperatureofouterwallsandthermalbridgepartsatroofsof
·3·
telecommunicationcentres(stations)shallnotbelowerthanthedewpointtemperatureofindoorairs.Whenthetemperaturedifferencebetweentheupperlayerair-conditionedroomsandlowerlayerair-conditionedroomoftelecommunicationcentres(stations)ishigh,itshallbeensuredthattheinternalsurfacetemperatureofupperandlowerroomsshallnotbelowerthanthedewpointtemperatureofindoorairs.
2.2.11Theplatformsforairconditioningoutdoorunitsoftelecommunicationcentres(stations)shouldbenearbytheairconditioningindoorunits.Theplatformsforairconditioningoutdoorunitsshouldbeopenwide,notfacingtothewest.Andproperareaofplatformforoutdoorunitsshallbereservedinaccordancewiththequantityandarrangementmodeofairconditioningoutdoorunits.
2.3RequirementsonDesignforEnergySavingofBuildingEnvelopesandMaterials
2.3.1Wallsoftelecommunicationcentres(stations)shallmeetthefoHowingrequirementsforthepurposeofenergysaving:
1Materialsforwallswithenergysavingfunctionshallbeadopted;
2Highefficientthermalinsulationmaterialsforbuildingsshallbeadopted;
3Buildingsatcold,hotsummerandcoldwinterandhotsummerandwarmwinterzones,whenlightstructuresareusedforwalls,shallbetakenwithcheckcalculationonthermalinsulationaccordingtorequirementsofThermalDesignCodeofCivilBuildingsGB50176;
4Forouterwallsoftelecommunicationcentres(stations)atseverecoldandcoldregions,whicharetobeinsulated,externalthermalinsulationstructuresshallbechosenfirstly.ThetechnologiesrecommendedbyTechnicalSpecificationforExternalThermalInsulationonWallsJGJ144-2004anddesignstandardsforenergysavingoflocalbuildingsshallbeadoptedinthedesign.
2.3.2Doorsandwindowsfortelecommunicationcentres(stations)shallmeetthefollowingrequirementsforthepurposeofenergysaving:
1Highenergyefficientglassshallbeadopted;
2Highenergyefficientmaterialsformakingframesofdoorsandwindowsshallbeadopted;
3Highenergyefficientdoorsandwindowsshallbeadopted;
4Thegastightnessofexternalwindowsoftelecommunicationcentres(stations)shallnotbelowerthánLevel4asstipulatedintheGraduationsandTestMethodsofAirPermeabilityforBuildingExternalWindowsGB/T7107-2002,withgoodperformanceindustproof,waterproof,fireprotection,windresistanceandheatinsulatingproperty,andsatisfyingtherequirementsoncleanlinessoftelecommunicationequipmentroomsdesignedaccordingtotelecommunicationtechnology;
5Fireproofdoors,withthermalinsulationpropertiesandinstalledwithdoorcloser,shouldbeselectedforequipmentroomsoftelecommunicationcentres(stations).
2.3.3Telecommunicationcentres(stations)roofsshallmeetthefollowingrequirementsforthepurposeofenergysaving:
1Accordingtodifferentregionsandconditionsforthermalinsulationofroofs,severalmeasuresshallbetaken,suchaslayinginsulatinglayersandinversiontyperoofs,settingupemptyspaceorairspaceandroofgreeningandsoon;
2Insulatinglayersofroofsshouldbemadeofmaterialswithlowwaterabsorption,lowdensityandheatconductivitycoefficient,certainstrengthandcorrosiveresistantforalongtermofimmersion.
2.3.4Floorsoftelecommunicationcentres(stations)shallmeetthefollowingrequirementsforthepurposeofenergysaving:
·4·
1Theheattransfercoefficientandthethermalresistanceofraisedoroutsidecarryfloors,floorsbetweenheatingroomsandnon-heatingrooms,surroundinggroundsornon-surroundinggroundsandouterwallsofheatingbasements(wallscontactingsoil),whichareattheundersurfacesoftelecommunicationcentres(stations)andcontactoutsideair,shallmeetrelevantrequirementsasstipulatedinArticle4.2.2ofDesignStandardforEnergyEfficiencyofPublicBuildingsGB50189-2005;
2Forinsulatinglayerslaidatgroundsandfloors,materialswiththestrengthcomplyingwithgroundrequirementsincludinghardextrudedpolystyreneboards,foamglassinsulationboardsandthelike,shallbeadopted,andthecombustionperformanceshallmeettherequirementsofexistingnationalstandardsandcodes.
2.4RequirementsonDesignforAirConditioningEnergySavingofTelecommunicationCentres(Stations)
2.4.1Airconditioningsystemsinnewlybuilttelecommunicationequipmentroomsshallmeetrelevantrequirementsofnationalenergysavingandenvironmentalprotection,andrelevantdesigningschemesshallbedeterminedaccordingtothescaleofbuildings,thefeatureonheatingdissipatingcapacityoftelecommunicationequipmentinstalled,localmeteorologicalconditionsandenergystateandviathetechno-economiccomparison.
2.4.2Forairconditioningsystemsofrenovationand/extensionprojects,thedesigningschemeshallbedeterminedaftercomprehensiveconsiderations,accordingtotheairconditioningmodeatoriginalbuildingsandrequirementsonusageofairconditioningsystemsofrenovationandextensionprojects.
2.4.3Duringthedesignofairconditioningsystems,theindoordesigntemperatureshallnotbelessthan26℃inthecasewherenormalworkingconditionsoftelecommunicationequipmentaresatisfied.
2.4.4Whenrelevantrequirementsaresatisfied,freshairvolumeshallbeloweredasmuchaspossibleinsummer,soastoreducetheairconditioningload.
2.4.5Duringthedesignoflcentralairconditioningsystems,outdoorairshallbeusedasnaturalcoldsourceintransitionseasonandwinteraccordingtolocalclimaticfeaturesofconstructionprojects,soastoreducetheoperationtimeofcoldwaterhost.
2.4.6Whendistributedairconditioningsystemsareused,theenergyeficiencyratio(EER)fordedicatedairconditionersatequipmentroomsshallbehigherthan2.8,andthesensibleheatratiohigherthan0.9.
2.4.7Themodeofdownsideairsupplyandtheupperairreturnshallbeadoptedforthetelecommunicationequipmentroomswithhighheatvalue.Theheightofraisedfloors,beingusedforairsupply,shallbedeterminedaccordingtothecalculationofsupplyairvolume,butthenetheightshallnotbelowerthan350mm.Thecablesoftelecommunicationequipmentshallnotbelaidundertheraisedfloors.
2.4.8Duringupperairsupplyofequipmentrooms,iftheairsupplydistanceforequipmentroomsiswithin10m,theairsupplymodewithdirectairinletfrommainblastlineofplenumchamberandthatwithairsupplycapshallbeadopted;iftheairsupplydistanceforequipmentroomsiswithin15m,theairsupplymodewithblastpipeshallbeadopted,andthedimensionsofairpipesandairdistributorsshallbedeterminedaccordingtocalculationofheatdissipatingcapacityoftelecommunicationequipment;iftheairsupplydistanceforequipmentroomsishigherthan15m,theairsupplymodewitharrangementofairconditioningindoorunitsattwosidesshallbeadopted.
2.4.9Horizontaldistanceandverticaldistanceofairconditioningindoorunitsandoutdoorunitsfortelecommunicationequipmentroomsshallbeasshortaspossible.
·5·
2.4.10Duringthedesignofairconditioningoutdoorunits,thespacingshallbedeterminedaccordingtotheairvolumedemandedforheatdissipationofoutdoorunits.
2.4.11Forequipmentroomoflargeareawithmanyairconditioners,wheretheheatdissipatingcapacityoftelecommunicationequipmentisuneven,whethertheself-adaptivecontrolsystemofairconditionerisadoptedshallbedeterminedbytechno-economiccomparison.
2.4.12Theenergysavingdesignforairconditionersatbasestationsshallmeetthefollowingrequirements:
1Fornewlybuiltbasestations,theenergysavingdesignshallbeconsidered;forbuiltuporexistingbasestations,properenergysavingmeasuresshallbetakenaccordingtositeconditionsforthepurposeofenergysavingreconstruction;
2Theenergysavingschemesforairconditionersatnewlybuiltandexistingbasestationsshallconsiderfactorssuchaslocalmeteorologicalandenvironmentalfactorsofbasestations,thestructureofequipmentroombuildings,equipmentlayout,equipmentpowerconsumptionandairfloworganizationofairconditionersandthelike.Theoptimalandcomprehensiveenergysavingschemewillbeselectedviatechno-economiccomparison.
2.5RequirementsonDesignofElectricalEnergySavingforTelecommunicationCentres(Stations)
2.5.1Lampsoftelecommunicationcentres(stations)shallmeetthefollowingrequirements:
1Thehighenergyefficientlightsourcesuchasfluorescentlamps,energysavinglamps,halogenlampsorLEDlampsshallbeselected,andforfluorescentlamps,T8orT5seriesthree-bandfluorescentlampsshallbeselected;fluorescentlampslareequippedwithelectronicballastandhalogenlampsareequippedwithhighefficientmagneticballast;
2Forhalogenlampsand/fluorescentlampsandthelikeproductsadoptingcapacitancecompensation,theirpowerfactorshallbehigherthan0.9;
3Lampsshallbeproductsofhighefficiency;theefficiencyofopentypelampswithreflexhousingshallnotbelessthan75%;theefficiencyofgrillelampsshallnotbelessthan60%.
2.5.2Theilluminancestandardoftelecommunicationcentres(stations)shallbeobtainedavaluestrictlyaccordingtorecommendationofnationalandprofessionalstandards.Forsomepartsofhighdemand,locallightingmaybeused.
2.5.3Controloflampsshallmeetthefollowingrequirements:
1Switchesofilluminationlampsshallbesetproperlyinequipmentrooms.Lampsneartowindowsshallbecontrolledindividually.Illuminationinequipmentroomsshallbecontrolledinseparatezones.Andlampsateachcontrolzoneshallhaveafullopenstateandahalfopencontrolstate;
2Switchesoflampsatstaircasesshallbeenergysavingself-extinguishingswitches;
3Illuminationforauxiliaryundergroundgaragesandwalkwaysshallbecontrolledbyzonesandintervals.
2.5.4Otherelectricequipmentshallmeetthefollowingrequirements:
1Fansandwaterpumpsshallbehighefficientandenergysavingproducts;
2Lifewaterpumpsandcommonlyusedfansthatarestartedfrequentlyshalladoptfrequencyconvertingcontrol;
3Centres(stations)withcentralairconditioningorlargeareashalladoptbuildingautomationcontrolsystems.
·6·
3RequirementsonEnergySavingofTelecommunication
EquipmentandInstallationDesign
3.1RequirementsonEnergySavingofTelecommunicationEquipment
3.1.1ThetemperatureandtherelativehumidityoftelecommunicationequipmentroomsshallbeinaccordancewithrequirementsofTable3.1.1.
Table3.1.1Thetemperatureandtherelativehumidityoftelecommunicationequipmentrooms
Telecommunicationequipment
Scopeoftemperature/℃
Scopeofrelativehumidity/%
ClassItelecommunicationequipmentrooms
+10-+26℃
40%-70%
ClassIⅡtelecommunicationequipmentrooms
+10-+28℃
20%-85%
ClassⅢtelecommunicationequipmentrooms
+10-+30℃
20%-90%
Notes:1Temperatureandrelativehumidityofquipmentroomsrefertotheraluemeasuredaaplace2mabovethegroundsurfaceand0.4minfrontofequipment.
2Thechangerateoftemperatueinelecommunicauonequpmentromshalbelessthan5C/h.
3Nocondensationisformedintelecommunicationequipmentrooms.
4ClassItelecommunicationequipmentroomsand/equipmentincludeDC1andDC2longdistanceexchangers,backbone/provincialtransitionpoints,backbone/provincialintlligentnetworkSCP,transmissioncentresatLevelIandⅡtrunklines,backbone/provincialbackbonedataequipment,internationalnetworkequipment,inter-provincialnetworkequipment,provincialnetworkequipment,naionalbackbonenetworksfordataserviceofChinaMobileNet(CMNET),thebusinesssystemconstructediniensivelynationwideandundertakethewholenetworkoregionausnes,LevelItrunklineequipmentforopticaltransportnetworkandpowerequipmentrooms.
5ClassⅡtelecommunicationequipmentroomsandequipmentincludetandemoffices,gateways,localintelligentnetworkSCP,backbonenodesatlocaltransmissionnetwork,localdatabackbonenodes,DCequipmentrooms,VIPbasestations,switchingequipmentforimportantusers(keydepartments),transmissionequipment,telecommunicationequipmentroomsfordatatelecommunicationequipmentandpowerequipmentrooms.
6ClasITelecommunicationequipmentroomsincludetelecommunicationquipmentroomsforcitycalledofices,data
equipmentroomsfordistributionlayersofmetropolitanareanetworksandaflatedpowerequipmentrooms,long-distancetransferrelaystations,commonbasestations,basestationsformarginalnetworksandnetworkoptimizationbasestations.
3.1.2Equipment(newlybuiltracks)ofcorenetworkincapacityexpansionmustadoptverticallyinsertedplatestructures.
3.1.3Anti-backflowmeasuresshallbetakeninracksoftelecommunicationequipmentrooms.
3.1.4Thetelecommunicationequipmentmayadoptlowerairintakemode,frontairdraftmodeorsideairintakemode.Ifairaresuppliedfromtheblowing-insideofairconditioner,theapertureratioofplatesfortelecommunicationequipmentshallnotbelowerthan50%.
3.1.5Telecommunicationequipmentshalloptimizeitspowermanagementbyintelligentsoftware,toreduceconsumptionofequipmentbyintelligentpowermanagement.
3.2RequirementsonEnergySavingforInstallationDesignofTelecommunicationEquipment
3.2.1Typeselectionoftelecommunicationequipmentshallmeetthefollowingrequirements:
1Onpreconditionthattechnicalandserviceindexesaresatisfied,equipmentofhighintegration,lowpowerconsumptionandenergysavingtechnologyshallbeselectedpreferentially.
·7·
2Onpreconditionthatnormaloperationandmaintenanceofequipmentaresatisfied,productswithnaturalheatdissipationfunctionshallbeselectedpreferentially,soastoreducetheusageoffans;
3Equipment,inwhichcarriersandthelikecomponentsofbasestationscanbeturnedon/offaccordingtothebusinessvolumeload,shouldbeselected.Whenthenetworkloadislower,partsofcarriersmaybeturnedoff.
3.2.2Inthedesign,varioustelecommunicationequipmentshallbeusedcomprehensively,soastoreducethequantityofequipmentandsupportingfacilities,andthefollowingrequirementsshallbecompliedwith:
1Takefulluseofauxiliaryresourcesatexistingsites,andshareequipmentrooms,powersupplyandairconditionersandthelikefacilities;
2Whenindoorcoversystemsarebuilt,differentservicepatternsoftelecommunicationsystemsshouldsharethedistributionsystem,soastoreducethequantityofrelevantdevicesandfeedersandusageofactivedevices.
3.2.3Onpreconditionthatensuresafetyandconvenienceformaintenance,telecommunicationequipmentshallbearrangedproperly,andfollowingrequirementsshallbecompliedwith:
1Inthetelecommunicationequipmentroomstheequipmentframecolumnspacingshallbedeterminedaccordingtoheatdissipatingcapacityoftelecommunicationequipmentandexpectedairvolumeofairconditioners;
2Whenequipmentoftelecommunicationequipmentroomsarearranged,relativelyindependentcoldandhotpassagesshallbemarkedoff,topreventcoldairmixingwithhotairbeforeenteringtheracks.
3.2.4Duringthedesignnetworksshallbeorganizedandoptimizedproperly.Variousnewenergysavingtechnologiesshallbetakenactively,andfollowingrequirementsshallbecompliedwith:
1Complywiththedevelopingtrendoftelecommunicationtechnology,anduseIPtechnologyArchitectureNetwork;
2Optimizethedesignofnetwork,simplifythenetworkstructure,enhancethenetworkutilizationandavoidequipmentbeingleftunused;
3Whenawirelessnetworkschemeisformulated,theoverlappingregioncoveredbybasestationsshallbereducedtothegreatestextent,onpreconditionthatthecoverageindexandqualityrequirementsaresatisfied,and,besides,varioustechniquesforenhancingcoverageshallbeutilizedreasonablysoastosaveresourcesofsitesandequipmentofbasestations;
4Whenatransmissionnetworkisbuilt,advancedtransmissiontechniquesshallbeselectedpreferentiallyfornetworkorganization,soastoreducethequantityofnetworkequipment,andSDHequipmentshalladopthigh-capacitynodeequipment,substitutingmultiterminalequipment;
5WhenalongdistanceWDMsystemisbuilt,thesuperlongdistancetransmissiontechniqueshallbeselectedpreferentially,soastoreducethesettingoflightregenerationsitesandlightamplifyingsite(OA);
6Promotethemulti-servicetransportplatform(MSTP)technologyactively,anduseanunifiedplatformforcarryingtraditionalanddataservices,soastoavoidadditionaltransmissionequipmentduetoincreasingofdataservices.
·8·
4RequirementsonEnergySavingofPowerSupplyandDistributionSystems
4.1GeneralRequirements
4.1.1Followingenergysavingmeasuresshallbetakenduringthedesignofpower/supplyanddistributionsystems.
4.1.2Inthedesign,energysavingequipmentshallbeselected,toreducetheenergyconsumptionofequipmentandenhancetheoverallenergysavingeffectofthesystem,
4.1.3Inthedesign,thepowerfactorofpowersupplysystemshallbeashighaspossible,andtheharmonicsuppressionshallbeperformedactively.
4.1.4Accordingtoloadingcapacity,powersupplydistanceanddistributionandfeaturesofelectricequipmentandthelikefactors,thecentralizedpowersupplymodeordistributedpowersupplymodeforpowerdistributionsystemsshallbeselectedproperlyandthequantityofconductorsshallbereduced,andpropercross-sectionofconductorsandlinelayingschemesshallbeselected,soastoreducethelossofdistributionlines.
4.2RequirementsonSelectionandConfigurationofEquipment
4.2.1Typeselectionofpowerequipmentshallmeetthefollowingrequirements:
1Selecttheenergysavingtypeofequipmentcertifiedbynationalcertificationbodies;
2Selectthedistributionequipmentincompliancewithrequirementsofnationalenergysavingstandards;
3Basestationswithhigh-frequencyswitchrectifiershouldadoptequipmentofthesmartsleepmode;
4Theefficiencyofswitchingpowersupplyanduninterruptiblepowersupply(UPS)shallmeettherequirementsofrelevantnationalandprofessionalstandards.
4.2.2Selectionandconfigurationofpowertransformerequipmentshallmeetthefollowingrequirements:
1Transformersshallbe
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 工会减肥活动方案策划(3篇)
- 庭院吊桥施工方案(3篇)
- 内分泌代谢护理培训课件
- 环保设施运行保养管理制度(3篇)
- 疫情时代企业薪金管理制度(3篇)
- 破冰活动策划方案名称(3篇)
- 绿色森林物业管理制度(3篇)
- 装饰装修工程现场管理制度(3篇)
- 酒店化学管理制度及流程(3篇)
- 《GAT 738.3-2007保安服务管理信息规范 第3部分:保安服务对象编码》专题研究报告深度
- 四川省乐山市高中高三上学期第一次调查研究考试数学试题【含答案详解】
- 《创新创业基础》课件-项目1:创新创业基础认知
- 2026年初一寒假体育作业安排
- 物流行业运输司机安全驾驶与效率绩效评定表
- 2026北京市通州区事业单位公开招聘工作人员189人笔试重点基础提升(共500题)附带答案详解
- 2025~2026学年山东省菏泽市牡丹区第二十一初级中学八年级上学期期中历史试卷
- 2026国家统计局仪征调查队招聘辅助调查员1人(江苏)考试参考试题及答案解析
- 水利工程施工质量检测方案
- 2025年北京高中合格考政治(第一次)试题和答案
- 卵巢类癌诊治中国专家共识(2025年版)
- 中国农业科学院2026年度第一批统一公开招聘笔试考试参考试题及答案解析
评论
0/150
提交评论