跨国制药企业HVAC系统IQ方案_第1页
跨国制药企业HVAC系统IQ方案_第2页
跨国制药企业HVAC系统IQ方案_第3页
跨国制药企业HVAC系统IQ方案_第4页
跨国制药企业HVAC系统IQ方案_第5页
已阅读5页,还剩16页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

INSTALLATIONQUALIFICATION

OFTHE

LINE9(AHU20&20A)HVACSYSTEM

ZYDISPRODUCTIONFACILITYNo.2

CompiledbyR.Sanders

Scope:ThisprotocoldetailstheIQworkrequiredtovalidatethenewHVACsystemfor

Line9ZydisproductionfacilityNo.2.

ApprovalsSignatureDate

Validation

Quality

1SYSTEMDESCRIPTION

HVACsystem9isafixedfreshairrecirculatingtypesystem,hasbeeninstalledas

partoftheLine9intheZydisProductionFacilityNo.2andservestheproduction

areasindicatedinthetablebelow:-

Note:Thislineisalsoreferredtoinsomedocumentationas'Xtraline".

HVACSystem9(AHU20&20A)

Room/AreaTitle

G380ProductionCorridor

G381Airlock

G384FreezeDryerPlantroomAirlock

G382FreezeDryerLoad/Unload

G385ProductionArea

G386Airlock

G387Warehouse/ProductionAirlock

MakeupairisdrawnintotheprimaryAirHandlingUnits(AHU)passingthroughan

electricpre-heater,bagFilter(EU4),pre-coolingcoilandbagfilter(EU8)before

passingontothede-humidifierunitandsecondaryAHU.Thede-humidifierunitis

installedonafixedflowbypassducting(offthemainductworkbetweentheprimary

andsecondaryAHUs)andprocessesonlyaproportionofthemainairflow.Inthe

secondaryAHUtheairpassesthroughafurtherelectricalheater,acoolingcoil,a

pleatedfilter(EU8)andattenuatorbeforefinaldistributionthroughductworkand

dampersintotherooms.

Extractairfromtheroomspassesthroughanattenuatorbeforere-enteringtheprimary

AHUtobere-circulatedaroundthesystem

Theproductionareaisalsoservedbytwoindependentroomextractsfortheseal

stationandthefreezetunnelwhichdischargeoutsidethebuilding.

2SPECIFICATION

Collatetogetheralldocumentswhichrelatetospecifyingandprocuringthis

equipment.Thiswillnormallyincludesomeorallofthefollowingdocuments:

Quotationfromsupplier,Ordertosupplier,Acknowledgmentfromsupplier,Variations

totheorderandanyacknowledgments,Tenderdocuments,Workpackagesetc.

Attachthedocumentslistedasappendiceswherepractical.Fordocumentswhich

arenotattached,givethereasonbelowthetableandareferenceastowherethe

documentisavailable.

TYPEOFDOCUMENTREFERENCEOFDATEOFAPPENDIX

DOCUMENTDOCUMENTNO.

Comments:

CompletedbyDate

3PRE-QUALIFICATIONHISTORY

Listbelowalltests/modificationsmadetotheequipmentoritsdesignduringandasa

resultofinstallationandcommissioning.Recordthereasonforeachmodification,

anddefinetheupdatedtechnicaldata(drawings,specifications,etc.).

TESTS/MODIFICATIONSREASON

Comments:

CompletedbyDate

SAFETY

Listinthetablebelowallsafetyfeatures(e.g.interlocks,emergencystops,etc.)

incorporatedintotheHVACSystem.

FEATUREFUNCTIONLOCATION

Comments:

CompletedbyDate

5SYSTEMSPECIFICATION

5.1Inspectthesysteminstallationandconfirmthatthefollowingspecifiedrequirements

havebeenmet.

SpecificationRequirementCompliesSignatureComments

withDate

spec.

Ductwork

SupplyandrecirculationductworkYes/No

insulated.

lnsulation:-(CircularductsuptoYes/No

350mmdiameter).

Rigidphenolicfoamsectionswith

factoryappliedaluminiumfacingfoil

Insulation:-(allotherductsizes)Yes/No

Rigidphenolicfoamlaminateboard

withreinforcedaluminiumfoilfacing

FlexibleductworkinsulatedwithYes/No

mineralfibre

ThedehumidifierprocessexhaustYes/No

ductworkinstalledinstainlesssteel

AllrigidductworkshallbemadefromYes/No

hot-dipgalvanizedsheet

AccesscoversshallbelocatedYes/No

adjacenttoallfiredampers,volume

controldampers,heating/coolingcoils

andfilters

CompletedbyDate

5.1SystemSpecification(continued)

SpecificationRequirementCompliesSignatureComments

withDate

spec.

TestholessealedwithYes/No

removable/resealableplugs

FlexibleductsusedtojoinrigidYes/No

ductworktoterminals.

Internalductworkclean.Yes/No

AllmanuallysetdampershaveaYes/No

lockablevisualbladepositionindicator

DampersinstalledforbalancingorYes/No

controlshallbegalvanizedsteel

Ductworkcorrectlylabelledwith

directionofflow

Ductworkcolourcoding:-

Freshair-Greentrianglewith'FA'Yes/No

notation(black)ontriangle

Supplyair-Red/Bluetrianglewith'SA'

Yes/No

notation(black)ontriangle

Recirc.air-Greytrianglewith'RA'

notation(black)ontriangleYes/No

Exhaustair-Browntrianglewith'EA'

notation(black)ontriangleYes/No

CompletedbyDate

5.1SystemSpecification(continued)

SpecificationRequirementCompliesSignatureComments

withDate

spec.

AirHandlingUnits(AHU)

AHUsModularframeconstructionwithYes/No

doubleskinned,thermallyinsulated

panels.Eachsectionlabelledwith

engravedtraffoyltenameplateof

uniquereference.

AHUsfittedwithreadilyremovableYes/No

panelstoprovideinternalaccessto

theunitwithkeyoperatedpositive

latches.Largepanelshingemounted.

PrimaryfiltersinAHUmountedonYes/No

sliderailstoallowsidewithdrawalwith

suitableaccessupstreamand

downstreamasrequired.

Eachfilterbankfittedwith0-500paYes/No3filterbanksintotal.

magnahelicgauge

BottomofcoolingcoilcasefittedwithYes/No

watertightdriptrayinstainlesssteel

withdrainconnection

CoolingcoilcasingboltedtofullwidthYes/No

diaphragmplateandsliderail

mountedforeaseofwithdrawaland

distortion.

CoolingcoilsfittedwithbindertypeYes/No

testpointoninletandoutlet,highlevel

airventandlowleveldraincockon

pipeworkconnections

CoolingcoilpressuretestcertificatesYes/No

available.

CompletedbyDate

5.1SystemSpecification(continued)

SpecificationRequirementCompliesSignatureComments

withDate

spec.

FansandmotorsframemountedYes/No

incorporatinganti-vibrationmountings.

Fanpulleys,beltsandmotordrivesYes/No

mountedexternaltothefanunit

appropriateflexiblejointsandisolation

mounts.

BeltdrivesshallincorporateaYes/No

minimumof2belts/drivewithmotor

positionfullyadjustableforbelt

tension.

Alladjustmentsareseparately

lockable

Fanmotorlocalisolatorfitted.Yes/No

EquipmentitemstaggedYes/No

DrainpointsinstalledforcoolingcoilYes/No

condensatewithairbreaks

Installationreportstestsheets

FireDamperInstallationtestsheetsYes/No

Faninstallationtestsheets.Yes/No

MagnahelicgaugetestsheetsandYes/No

calibrationcertificates.

FilterinstallationtestsheetsYes/No

Dehumidifierairleakagetestsheets.Yes/No

DuctworkairleakagetestsheetsYes/No

AHUairleakagetestsheets.Yes/No

CompletedbyDate

5.1SystemSpecification(continued)

SpecificationRequirementCompliesSignatureComments

withDate

Section2partsAandB

spec.

Installationreportstestsheets

(BEMS)AirPressureDevicestestYes/No

sheet

(BEMS)AirTemp,andHumiditytestYes/No

sheet

(BEMS)ControlValvestestsheetYes/No

(BEMS)MotorisedDamperValvesYes/No

testsheet.

(BEMS)AirTemperatureandHumidityYes/No

DevicesCalibrationtestsheet..

(BEMS)AirPressureDevicesYes/No

Calibrationtestsheet.

CompletedbyDate

5.1SystemSpecification(continued)

SpecificationRequirementCompliesSignatureComments

withDate

Section2partsAandB

spec.

Commissioningreportsandtestsheets

EquipmentmanufacturersYes/No

service/commissioningreports

AirDistributionSystemspre-Yes/No

commissioningsheet

AirDistributionSystemsFireDamperYes/No

commissioningsheet

CircularDuct-airflowvolumepitotYes/No

traversecommissioningsheet

RectangularDuct-airflowvolumeYes/No

pitottraversecommissioningsheet

AirDistributionSystemsterminalYes/No

deviceairflowvolumecommissioning

sheet

AirDistributionSystemsFanYes/No

commissioningsheet

DuctworkstaticpressureprofileYes/No

commissioningsheet

MagnahelicgaugecommissioningYes/No

sheet

HVACsystemssummaryYes/No

commissioningsheet

CompletedbyDate

6SYSTEMFEATURES

IDENTIFICATIONANDCHECKSOFTHEPRINCIPALCOMPONENTSOFTHE

EQUIPMENT

VisualInspection

Thefollowingcomponentswillbegivenafullvisualinspectiontoverifythattheyare

presentasspecified,arecorrectlydocumentedandhavebeeninstalledcorrectly.

Anydeviationsfromthespecificationordocumentationandincorrectinstallations

mustbecommentedon.Thedetailsindicatedwillberecordedfortheequipmentas

installed.

6.1Dehumidifier

Supplier:Munters

ModelNo:

SerialNo:

SpecificationSpecifiedInstalled

Max.Flowrate7.757m3/s

De-humidification2.11m3/s

capacity

Humidityextractsilicagel

system

ReactivationHeaterGaspowered

Comments

CompletedbyDate

6.2AirHandlingUnit(AHU20)

Supplier:AirHandlingEquipmentLtd

ModelNo:

SerialNo:

SpecificationSpecifiedInstalled

FantypeCentrifugal

Fanduty7.757m3/s

Motorrating18.5KW

DrivetypeInternalmotorandbelts

Pre-filterNo.1EU4shortbagNBS80%Dimensions

Type

Pre-filterNo.2EU8longbagNBS95%Dimensions

Type

Pre-heatingmediumElectric

Pre-coolingmediumChilledwater

IsolationdampertypeBareshaftforactuator

mounting

MixingboxdamperManuallyopposed

Comments

NBS(American)NationalBureauofStandards

CompletedbyDate

6.2AirHandlingUnit(AHU20A)

Supplier:AirHandlingEquipmentLtd

ModelNo:

SerialNo:

SpecificationSpecifiedInstalled

HeatingmediumElectric

CoolingmediumCalledwater

Final-filterPleatedRigidEU8NBS95%Dimensions

Type

Comments

NBS(American)NationalBureauofStandards

CompletedbyDate

7DRAWINGSCHECK

Obtainprintsofthecomponentandservicesdrawings,identifytheseinthe

tablebelow:

DRAWINGNo.DRAWINGTITLEREVISIONAPPENDIX

No.No.

G0386/M006ProductionAreaHVAC

Schematic

G0386/M002CeilingVoidmechanical

ServicesProductionArea/

FirstFloorPlantRoom

Clearlyidentifyallthefollowing:

1)Allcorrections.

2)Detailsnotverifiedandthereasonfornon-verification.

3)Discrepanciesbetweenthedrawingandtheinstalledequipment.

4)Detailsverified.

AnnotateeachdrawingwiththewordsINSTALLATIONQUALIFICATION

DRAWINGCHECK),signanddatethemarked-upprintswhenthechecksare

complete.Alsowritethisprotocoltitleandreferencenumberandtheappropriate

appendixnumberontheprint.Attachthemarked-upprintstothisprotocolasan

appendix.

Comments:

CompletedbyDate

8SERVICESCONNECTIONCHECK

Completethedetailsoftheasfittedservicesuppliesandcommentonany

discrepanciesbetweenthemandthoserecommendedbythesupplier.

SERVICERECOMMENDEDCONNECTED

Electricity415v3phase

NaturalGas

ChilledWater

Comments:

CompletedbyDate

9INSTRUMENTATION

InstrumentRangeandCategoryInstrument

Tolerance(1,2,3)ConfirmedPresent

ManufacturerandManufacturer'sInstrument

ModelSerialNumberNumber

DamperMotor3

BelimoSN21MS14001

00612

CoilFreezeProtection3

Thermostat

MS14002

00613

AirDifferentialPressure3

Transmitter(0-1000pa)

MS14003

00614

AirTemperatureTransmitter3

MS14004

00615

AirDifferentialPressure3

Transmitter(0-1000pa)

MS14005

00616

AirTemperatureand3

Humidity.Transmitter

MS14006

00617

AirDifferentialPressure3

Transmitter(0-1000pa)

MS14007

00618

AirTemperatureTransmitter3

MS14008

00619

AirDifferentialPressure3

Transmitter(0-1000pa)

MS14009

00620

AirTemperatureand3

Humidity.Transmitter

MS14010

00605

CompletedbyDate

InstrumentRangeandCategoryInstrument

Tolerance(1,2,3)ConfirmedPresent

ManufacturerandManufacturer'sInstrument

ModelSerialNumberNumber

AirTemperatureand3

Humidity.Transmitter

MS14011

00606

3portliquidcontrolvalveand3

actuator(Chilledwater)

MS14015

00610

3portliquidcontrolvalveand3

actuator(Chilledwater)

MS14016

00611

FanFlowmeter3

MS14031

00622

AirTemperatureand3

Humidity.Transmitter

MS14038

00621

AirTemperatureand3

Humidity.Transmitter

MS14039

00623

AirTemperatureand3

Humidity.Transmitter

MS14047

00624

AirTemperatureand3

Humidity.Transmitter

MS14048

00625

AirTemperatureand3

Humidity.Transmitter

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论