暖通施工技术HVACConstructionTechnology主讲教师:Lecturer:民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsofventilationandsmokecontrolsystemsincivilbuildings民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings读懂图纸Understandingthedrawings守护建筑的安全Protectingbuildingsafety保障人民的生命财产Safeguardingpeople’slivesandproperty民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings施工图的内容Contentofconstructiondrawings01通风系统Ventilationsystem施工图识图要点Keypointsforreadingconstructiondrawings02机械排烟系统Mechanicalsmokeextractionsystem施工图识图要点Keypointsforreadingconstructiondrawings03加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems04目录Contents施工图的内容Contentofconstructiondrawings01设计说明和施工说明Designnotesandconstructioninstructions通风空调设计与施工总说明(一)VentilationandAirConditioningDesignandGeneralConstructionNotes(I)施工图的内容Contentofconstructiondrawings设计说明介绍设计概况和通风方式,风量指标,建筑物的耐火等级,防排烟的方式,烟气的控制流程等。Thedesignnotesprovideanoverviewofthedesign,includingtheventilationmethod,airvolumespecifications,buildingfireresistancerating,smokecontrolstrategies,andtheproceduresforsmokemanagement.设计说明和施工说明Designnotesandconstructioninstructions施工说明介绍系统所使用的材料和附件,系统工作压力和试压要求,施工安装要求及注意事项等内容。Theconstructionnotesdescribethematerialsandaccessoriesusedinthesystem,systemworkingpressureandpressuretestingrequirements,installationrequirements,andimportantprecautionsforconstruction.通风空调设计与施工总说明(一)VentilationandAirConditioningDesignandGeneralConstructionNotes(I)施工图的内容Contentofconstructiondrawings平面图Plan各种通风设备Varioustypesofventilationequipment通风管道Ventilationduct施工图的内容Contentofconstructiondrawings通风与防风排烟平面图Ventilationandsmokecontrolplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings平面图Plan通风管道Ventilationduct平面图内容Contentsofthefloorplan通风与防风排烟平面图Ventilationandsmokecontrolplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings平面图Plan风口Airdiffuser通风管道Ventilationduct平面图内容Contentsofthefloorplan通风与防风排烟平面图Ventilationandsmokecontrolplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings平面图Plan通风设备Ventilationequipment风口Airdiffuser通风管道Ventilationduct平面图内容Contentsofthefloorplan通风与防风排烟平面图Ventilationandsmokecontrolplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings平面图Plan及其他设备Andotherequipment房间名称Roomname轴线号和尺寸线Axisnumbersanddimensionlines通风竖井Ventilationshaft通风设备Ventilationequipment风口Airdiffuser通风管道Ventilationduct平面图内容Contentsofthefloorplan通风与防风排烟平面图Ventilationandsmokecontrolplan及其他设备Andotherequipment房间名称Roomname轴线号和尺寸线Axisnumbersanddimensionlines通风竖井Ventilationshaft通风设备Ventilationequipment风口Airdiffuser通风管道Ventilationduct平面图内容Contentsofthefloorplan排风井与建筑物的定位尺寸Locationdimensionsoftheexhaustshaftrelativetothebuilding首层平面图Groundfloorplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings平面图Plan通风与防火排烟剖面图Ventilationandsmokecontrolsectionview通风与防风排烟平面图Ventilationandsmokecontrolplan外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser施工图的内容Contentofconstructiondrawings剖面图Cross-sectionView通风与防火排烟剖面图Ventilationandsmokecontrolsectionview正投影方式对应于平面图的设备Orthographicprojectionofequipmentcorrespondingtothefloorplan设备基础Equipmentfoundation管道和附件Pipingandaccessories注明设备和附件编号Indicateequipmentandaccessorynumbers标注竖向尺寸和标高Markverticaldimensionsandelevations剖面图Cross-sectionView施工图的内容Contentofconstructiondrawings通风与防火排烟系统图Ventilationandsmokecontrolsystemdiagram外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox阻燃型柔性短管Flame-retardantflexibleshortduct手动对开多叶调节阀Manualopposed-bladedamperSFT-1型SFT-1model蛋格式开启风口Egg-cratetypesupplyairdiffuser系统图Systemdiagrams也称通风管道系统轴测图Alsoknownastheisometricdiagramoftheventilationductsystem施工图的内容Contentofconstructiondrawings详图Detaildrawings风机房Fanroom防火阀门Firedamper管道交叉处Pipingintersection防火阀安装详图Firedamperinstallationdetail施工图的内容Contentofconstructiondrawings风机房Fanroom防火阀门Firedamper管道交叉处Pipingintersection详图Detaildrawings防火阀安装详图Firedamperinstallationdetail保温层Insulationlayer(排风管不做)(Exhaustductnotprovided)伸缩缝Expansionjoint保温层(排风管不做)Insulationlayer(exhaustductnotprovided)检查门Accessdoor检查门Accessdoor防火调节阀Firedamperwithregulatingfunction防火调节阀Firedamperwithregulatingfunction金属软管Flexiblemetalconduit施工图的内容Contentofconstructiondrawings设备及管道的平面位置Planlocationofequipmentandpiping设备与管道的连接方式Connectionmethodbetweenequipmentandpiping管道走向Pipingrouting管道规格Pipespecifications仪表及阀门Instrumentsandvalves控制点标高Controlpointelevation详图Detaildrawings轴流风机安装详图Axialfaninstallationdetail弹簧吊钧Springsuspensionhanger吊杆Hanger
rod软接管Flexibleconnector轴流风机Axialflowfan膨胀螺栓Expansionbolt槽钢吊架Channelsteelhanger急停开关Emergencystopswitch施工图的内容Contentofconstructiondrawings通风系统施工图识图要点Keypointsforreadingconstructiondrawingsofventilationsystems02外墙式排风口Externalwallexhaustairoutlet排风系统平面图Exhaustsystemfloorplan变风量风机箱Variableairvolumefanbox单层百叶排风口Single-deflectionlouveredexhaustairoutlet外墙式排风口Externalwallexhaustairoutlet通风系统施工图识图要点Keypointsforreadingconstructiondrawingsofventilationsystems送风系统平面图Supplyairsystemfloorplan进风机房Freshairhandlingunitroom顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m混流风机SWF-A-I-5L=8652m3/hP=196Pan=1450r/minN=1.1KwMixedflowfanSWF-A-I-5,airflowrate=8652m³/h,staticpressure=196Pa,speed=1450r/min,power=1.1kW中心标高-2.90mcenterelevation=-2.90m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出
带调节装置Supplyfaninterlock,electricalsignaloutput,equippedwithregulatingdevice单层百叶送风口800×400顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×400,ceilingelevation=-0.70m顶-0.70mceilingelevation-0.70m单层百叶送风口800×320顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×320,ceilingelevation=-0.70m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出带
调节装置Supplyfaninterlock,electricalsignaloutputwithregulatingdevice通风系统施工图识图要点Keypointsforreadingconstructiondrawingsofventilationsystems进风机房Freshairhandlingunitroom顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m混流风机SWF-A-I-5L=8652m3/hP=196Pan=1450r/minN=1.1KwMixedflowfanSWF-A-I-5,airflowrate=8652m³/h,staticpressure=196Pa,speed=1450r/min,power=1.1kW中心标高-2.90mcenterelevation=-2.90m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出
带调节装置Supplyfaninterlock,electricalsignaloutput,equippedwithregulatingdevice单层百叶送风口800×400顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×400,ceilingelevation=-0.70m顶-0.70mceilingelevation-0.70m单层百叶送风口800×320顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×320,ceilingelevation=-0.70m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出带
调节装置Supplyfaninterlock,electricalsignaloutputwithregulatingdevice通风系统施工图识图要点Keypointsforreadingconstructiondrawingsofventilationsystems送风系统平面图Supplyairsystemfloorplan地下室排风系统平面图Basementexhaustsystemfloorplan通风系统施工图识图要点Keypointsforreadingconstructiondrawingsofventilationsystems机械排烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofmechanicalsmokeextractionsystem顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice03地下室排烟平面图Basementsmokeexhaustfloorplan机械排烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofmechanicalsmokeextractionsystems排烟防火阀630×320
280℃关闭Smokecontrolfiredamper630×320,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice630×320顶-0.70m630×320,ceilingelevation-0.70m单层百叶排风口800×320Single-deflectionlouveredexhaustairoutlet800×320,共2个quantity:2共2个quantity:2单层百叶排风口400×400Single-deflectionlouveredexhaustairoutlet400×400,FM甲1221FM-A1221FM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70mFM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m消防低噪声柜式离心风机HTFC-A-II-No.18L=16440m/hn=1000r/minN=8kWFirefightinglow-noisecabinetcentrifugalfanHTFC-A-II-No.18,airflowrate=16,440m³/h,Speed=1000r/min,power=8kW排烟机房Smokeexhaustfanroom排烟口Smokeexhaustoutlet排烟防火阀1000×320
280℃关闭Smokecontrolfiredamper1000×320,closesat
280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice配电室Powerdistributionroom单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200
280℃关闭Smokecontrolfiredamper400×200,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice排烟防火阀1000×320280℃关闭Smokecontrolfiredamper1000×320,closesat280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput地下室排烟平面图Basementsmokeexhaustfloorplan排烟管道采用不燃材料制作Smokeexhaustductsshallbemadeofnon-combustiblematerials吊顶内的排烟管道Smokeexhaustductslocatedaboveceilings隔热层采用不燃烧材料制作Thermalinsulationlayersshallbeconstructedfromnon-combustiblematerials与可燃物保持不小于150mm的距离Aminimumdistanceof150mmshallbemaintainedfromcombustiblematerials排烟防火阀630×320
280℃关闭Smokecontrolfiredamper630×320,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice630×320顶-0.70m630×320,ceilingelevation-0.70m单层百叶排风口800×320Single-deflectionlouveredexhaustairoutlet800×320,共2个quantity:2共2个quantity:2单层百叶排风口400×400Single-deflectionlouveredexhaustairoutlet400×400,FM甲1221FM-A1221FM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70mFM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m消防低噪声柜式离心风机HTFC-A-II-No.18L=16440m/hn=1000r/minN=8kWFirefightinglow-noisecabinetcentrifugalfanHTFC-A-II-No.18,airflowrate=16,440m³/h,Speed=1000r/min,power=8kW排烟机房Smokeexhaustfanroom排烟口Smokeexhaustoutlet排烟防火阀1000×320
280℃关闭Smokecontrolfiredamper1000×320,closesat
280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice配电室Powerdistributionroom单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200
280℃关闭Smokecontrolfiredamper400×200,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice排烟防火阀1000×320280℃关闭Smokecontrolfiredamper1000×320,closesat280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput机械排烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofmechanicalsmokeextractionsystems地下室排烟平面图Basementsmokeexhaustfloorplan排烟防火阀630×320
280℃关闭Smokecontrolfiredamper630×320,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice630×320顶-0.70m630×320,ceilingelevation-0.70m单层百叶排风口800×320Single-deflectionlouveredexhaustairoutlet800×320,共2个quantity:2共2个quantity:2单层百叶排风口400×400Single-deflectionlouveredexhaustairoutlet400×400,FM甲1221FM-A1221FM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70mFM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m消防低噪声柜式离心风机HTFC-A-II-No.18L=16440m/hn=1000r/minN=8kWFirefightinglow-noisecabinetcentrifugalfanHTFC-A-II-No.18,airflowrate=16,440m³/h,Speed=1000r/min,power=8kW排烟机房Smokeexhaustfanroom排烟口Smokeexhaustoutlet排烟防火阀1000×320
280℃关闭Smokecontrolfiredamper1000×320,closesat
280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice配电室Powerdistributionroom单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200
280℃关闭Smokecontrolfiredamper400×200,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice排烟防火阀1000×320280℃关闭Smokecontrolfiredamper1000×320,closesat280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput机械排烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofmechanicalsmokeextractionsystems地下室排烟平面图Basementsmokeexhaustfloorplan排烟防火阀630×320
280℃关闭Smokecontrolfiredamper630×320,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice630×320顶-0.70m630×320,ceilingelevation-0.70m单层百叶排风口800×320Single-deflectionlouveredexhaustairoutlet800×320,共2个quantity:2共2个quantity:2单层百叶排风口400×400Single-deflectionlouveredexhaustairoutlet400×400,FM甲1221FM-A1221FM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70mFM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m消防低噪声柜式离心风机HTFC-A-II-No.18L=16440m/hn=1000r/minN=8kWFirefightinglow-noisecabinetcentrifugalfanHTFC-A-II-No.18,airflowrate=16,440m³/h,Speed=1000r/min,power=8kW排烟机房Smokeexhaustfanroom排烟口Smokeexhaustoutlet排烟防火阀1000×320
280℃关闭Smokecontrolfiredamper1000×320,closesat
280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice配电室Powerdistributionroom单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200
280℃关闭Smokecontrolfiredamper400×200,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice排烟防火阀1000×320280℃关闭Smokecontrolfiredamper1000×320,closesat280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput机械排烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofmechanicalsmokeextractionsystems加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems04加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems加压送风防烟系统平面图Pressurizedsupplyairandsmokecontrolsystemfloorplan标房AStandardroomA标房AStandardroomA标房AStandardroomA标房A走廊StandardroomAcorridor标房AStandardroomA标房AStandardroomA标房AStandardroomA标房AStandardroomA标房AStandardroomA标房AStandardroomA全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×200Dimensions:400×200风口底距地300mmDistancefromoutletbasetofloor:300mm套房Suite会客Lounge标房DStandardroomD空调机房Airconditioningequipmentroom上Up客房BGuestroomB客房BGuestroomB标房CStandardroomC下Down会客Lounge全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×250Dimensions:400×250风口底距地300mmDistancefromoutletbasetofloor:300mm全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×200Dimensions:400×200风口底距地300mmDistancefromoutletbasetofloor:300mm套房Suite加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems电梯机房防排烟平面图Elevatormachineroomsmokecontrolfloorplan剪刀楼梯间正压送风1
低噪声消防柜式离心风机Scissorstairwellpressurizedsupplyair1,
low-noisefirefightingcabinetcentrifugalfan型号:NDT-25-26335m3/h-651PaModel:NDT-25-26335m3/h-651Pa电梯机房Elevatormachineroom280℃防火阀Firedamper剪刀楼梯间正压送风2
低噪声消防柜式离心风机Scissorstairwellpressurizedsupplyair2,
low-noisefirefightingcabinetcentrifugalfan型号:NDT-25-26335m3/h-651PaModel:NDT-25-26335m3/h-651Pa280℃防火阀Firedamper合用前室正压送风
低噪声消防柜式离心风机Sharedanteroompressurizedsupplyair,
low-noisefirefightingcabinetcentrifugalfan型号:NDT-25-20813m3/h-410PaModel:NDT-25-20813m3/h-410Pa280℃防火阀Firedamper加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems风机的安装Faninstallation风口的安装Airoutletinstallation加压送风防烟系统施工图识图要点Keypointsforreadingconstructiondrawingsofpressurizedairsupplyandsmokecontrolsystems通风与防火排烟剖面图Ventilationandsmokecontrolsectionview外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox蛋格式开启风口Egg-cratetypesupplyairdiffuser通风与防火排烟平面图Ventilationandsmokecontrolsectionview民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings通风与防火排烟剖面图Ventilationandsmokecontrolsectionview民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings外墙式排风口Externalwallexhaustairoutlet变风量风机箱Variableairvolumefanbox阻燃型柔性短管Flame-retardantflexibleshortduct手动对开多叶调节阀Manualopposed-bladedamperSFT-1型SFT-1model蛋格式开启风口Egg-cratetypesupplyairdiffuser通风与防火排烟系统图Ventilationandsmokecontrolsystemdiagram民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings保温层Insulationlayer(排风管不做(Exhaustductnotprovided)伸缩缝Expansionjoint保温层Insulationlayer(排风管不做)(Exhaustductnotprovided)检查门Accessdoor检查门Accessdoor防火调节阀Firedamperwithregulatingfunctiont=70℃t=280℃防火调节阀Firedamperwithregulatingfunctiont=70℃t=280℃金属软管Flexiblemetalconduit防火阀安装详图Firedamperinstallationdetail民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings弹簧吊钧Springsuspensionhanger吊杆Hanger
rod软接管Flexibleconnector轴流风机Axialflowfan膨胀螺栓Expansionbolt槽钢吊架Channelsteelhanger急停开关Emergencystopswitch轴流风机安装详图Axialfaninstallationdetail民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings进风机房Freshairhandlingunitroom顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m混流风机SWF-A-I-5L=8652m3/hP=196Pan=1450r/minN=1.1Kw
MixedflowfanSWF-A-I-5,airflowrate=8652m³/h,staticpressure=196Pa,speed=1450r/min,power=1.1kW中心标高-2.90m,centerelevation=-2.90m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出
带调节装置Supplyfaninterlock,electricalsignaloutput,equippedwithregulatingdevice单层百叶送风口800×400顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×400,ceilingelevation=-0.70m单层百叶送风口800×320顶标高-0.70mSingle-deflectionlouveredsupplyairoutlet800×320,ceilingelevation=-0.70m防火阀630×40070℃关闭Firedamper630×400,closesat70°C送风机联动
电信号输出带
调节装置Supplyfaninterlock,electricalsignaloutputwithregulatingdevice送风系统平面图Supplyairsystemfloorplan民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings排烟防火阀630×320Smokecontrolfiredamper630×320280℃关闭Closesat280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice630×320顶-0.70m630×320,ceilingelevation-0.70m单层百叶排风口800×320Single-deflectionlouveredexhaustairoutlet800×320,共2个quantity:2共2个quantity:2单层百叶排风口400×400Single-deflectionlouveredexhaustairoutlet400×400,FM甲1221FM-A1221FM甲1221FM-A1221FM甲1221FM-A1221顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m顶-0.70mceilingelevation-0.70m消防低噪声柜式离心风机HTFC-A-II-No.18L=16440m/hn=1000r/minN=8kWFirefightinglow-noisecabinetcentrifugalfanHTFC-A-II-No.18,airflowrate=16,440m³/h,Speed=1000r/min,power=8kW排烟机房Smokeexhaustfanroom排烟口Smokeexhaustoutlet排烟防火阀1000×320
280℃关闭Smokecontrolfiredamper1000×320,closesat
280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200280℃关闭Smokecontrolfiredamper400×200,closes排烟风机联动
电信号输出
带调节装置at280°C;smokeexhaustfaninterlock,electricalsignaloutput,equippedwithregulatingdevice配电室Powerdistributionroom单层百叶排风口400×250Single-deflectionlouveredexhaustairoutlet400×250排烟防火阀400×200
280℃关闭Smokecontrolfiredamper400×200,closesat
280°C排烟风机联动
电信号输出
带调节装置Smokeexhaustfaninterlock,electricalsignaloutput
withregulatingdevice排烟防火阀1000×320280℃关闭Smokecontrolfiredamper1000×320,closesat280°C排烟风机联动
电信号输出Smokeexhaustfaninterlock,electricalsignaloutput地下室排烟平面图Basementsmokeexhaustfloorplan民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings标房AStandardroomA标房AStandardroomA标房AStandardroomA标房A走廊StandardroomAcorridor全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×200Dimensions:400×200风口底距地300mmDistancefromoutletbasetofloor:300mm标房AStandardroomA套房Suite套房Suite会客Lounge会客Lounge标房DStandardroomD空调机房Airconditioningequipmentroom上Up客房BGuestroomB客房BGuestroomB标房AStandardroomA标房AStandardroomA标房AStandardroomA标房AStandardroomA标房AStandardroomA标房CStandardroomC下Down全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×250Dimensions:400×250风口底距地300mmDistancefromoutletbasetofloor:300mm全自动正压送风口Fullyautomaticpressurizedsupplyairoutlet型号:PYKZ24/0.2Model:PYKZ24/0.2尺寸:400×200Dimensions:400×200风口底距地300mmDistancefromoutletbasetofloor:300mm加压送风防烟系统平面图Pressurizedsupplyairandsmokecontrolsystemfloorplan民用建筑通风与防排烟系统施工图识读Readingconstructiondrawingsforventilationandsmokecontrolsystemsincivilbuildings暖通施工技术HVACConstructionTechnology风管的分类与常用材料认知ClassificationofDuctsandIntroductiontoCommonlyUsedDuctMaterials主讲教师:Lecturer:暖通施工技术HVACconstructiontechnology风管,是用于空气输送和分布的管道系统。本节课我们学习风管的分类与风管制作常用材料。Aductisapipingsystemusedfordeliveryanddistributionofair.Inthislesson,wewillstudytheclassificationofductsandthecommonmaterialsusedinductfabrication.一、风管的分类I.ClassificationofDucts按材质Bymaterial金属材料风管Metalduct非金属材料风管Non-metallicduct复合材料风管Compositeduct风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials金属风管Metalduct钢板、镀锌钢板、不锈钢板、铝板...Steelsheet,galvanizedsteelsheet,stainlesssteelsheet,aluminumsheet,etc.非金属风管Non-metallicduct硬聚氯乙烯、无机玻璃钢、有机玻璃钢...RigidPVC,inorganicfiberglass-reinforcedplastic,organicfiberglass-reinforcedplastic,etc.复合风管Compositeduct酚醛铝箔复合板、聚氨酯复合板、玻璃纤维复合板...Phenolicaluminumfoilcompositepanels,polyurethanecompositepanels,fiberglasscompositepanels,etc.按材质Bymaterial一、风管的分类I.ClassificationofDucts风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials按工作压力Byoperatingpressure微压系统Micro-pressuresystem低压系统Low-pressuresystem中压系统Medium-pressuresystem高压系统High-pressuresystem一、风管的分类I.ClassificationofDucts风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials按工作压力Byoperatingpressure125Pa<p≤500Pap≤125Pa500Pa<p≤1500Pa1500Pa<p≤2500Pa微压系统Micro-pressuresystem低压系统Low-pressuresystem中压系统Medium-pressuresystem高压系统High-pressuresystem一、风管的分类I.ClassificationofDucts风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials(一)金属风管常用材料(I)CommonMaterialsforMetalDucts俗称黑铁皮Commonlyreferredtoasblacksteelsheet厚度0.5~2.0mmThickness:0.5–2.0mm机械强度和加工性能良好Goodmechanicalstrengthandworkability便宜Inexpensive普通薄钢板Ordinarythinsteelsheet风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials二、风管常用材料与风管制作材料要求II.CommonMaterialsforDuctworkandMaterialRequirementsforDuctFabrication(一)金属风管常用材料(I)CommonMaterialsforMetalDucts表面呈银白色,又称白铁皮Silver-whitesurface,alsoknownastinplate厚度0.25~2.0mmThickness:0.25–2.0mm通风空调工程中厚度为0.5~1.5mmForventilationandairconditioningprojects,typicalthicknessis0.5–1.5mm具有良好的防腐性能Goodcorrosionresistance镀锌薄钢板Galvanizedthinsteelsheet风管的分类与常用材料认知Classificationofductsandintroductiontocommonlyusedductmaterials二、风管常用材料与风管制作材料要求II.CommonMaterialsforDuctworkandMaterialRequirementsfor
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 关于2026年市场调研报告审阅的商洽函6篇范本
- 2026年网络安全策略更新函7篇范本
- 事业单位计算机岗面试历年真题题库及答案
- 客户满意度及业务绩效考评表
- 辐射作用课件
- 关于完成样品测试结果回复函4篇范本
- 放射治疗肺癌讲解课件
- 2026年自考跨境电子商务模拟试题带答案
- 影视项目进阶效率考核表
- 仿生与科幻课件
- 2026年黑龙江省龙东地区中考数学试卷(含答案及解析)
- 《AI通识》学习资料-题库-温州市继续教育-一般公需课
- 2025年检察院案件管理办公室工作人员招聘考试真题及答案
- 中华民族共同体概论课件专家版6第六讲五胡入华与中华民族大交融(魏晋南北朝)
- 2024-2025学年度黑龙江交通职业技术学院单招考试文化素质数学模拟题库含答案详解(考试直接用)
- 医疗行业5S管理培训
- 消防队通信员培训课件
- 市政管网施工课件
- (已压缩)(3)义务教育语文课程标准日常修订版(2022年版2025年修订)
- T-DGGC 022-2023 盾构机保养与维修技术规范
- 家庭管家培训知识课件
评论
0/150
提交评论