1、CISPR 15,EN 55015,CNS 14115,.測試指導,範圍 測試規範及各國管制方式 測試儀器及測試場地規格要求 產品分級及限制值(Classification & Limit) 測試條件( Measurement condition ) 量測方法( Method of measurement ) 測試判定,範圍,主要功能為產生或散發光的照明設備(電源及電池) 多功能設備之發光部分,主要為照明功能部分 配合照明設備使用的獨立輔助裝置 UV及IR設備 廣告霓虹燈(尚無限制值) 室外用之街燈/投光燈 運輸工具照明(buses&trains) 頻率範圍 9kHz 400 GHz,測試規範

2、及各國管制方式,CISPR 15 / EN 55015 CNS 14115 FCC Part 18,測試儀器及測試場地規格要求,LISN (50 /50H+5 or 50 /50H ) Triple Loop Antenna 2m(EUT max. 1.6m) Radio frequency generator (50) Balance-to-unbalance transformer Dummy lamps,產品分級及限制值(Classification & Limit),白炙燈具(鹵素燈)未加裝燈光調節裝置及電子開關設備-視同符合規範要求可免測 具起動器之螢光燈具且為下述燈管形式所設計之燈

3、具須符合Insertion loss Limit 直管螢光燈其直徑為15mm,25mm,or 38mm 圓形螢光燈其直徑為28mm or 38mm U形螢光燈其直徑為15mm,25mm,or 38mm 單燈頭螢光燈無起動器其直徑為15mm 單燈頭螢光燈直線型,2及4管有起動器其直徑為12mm 其他室內燈具須符合mains terminal voltage limit.若燈管端工作頻率超過100Hz須符合field strength limits.若有外部調節裝置須符合disturbance voltage at the control terminals limits,Table 1 Mini

4、mum values of insertion loss,Table 2a-Disturbance voltage limits at mains terminals,Table 2b-Disturbance voltage limit at load and control terminals,Table 3-Radiated electromagnetic disturbance limits,Table 4-Limits of disturbance field strengths at frequencies designated for use by ISM equipment,測試

5、條件( Measurement condition ),電壓 2% 環境溫度 15 25 枯化時間 2h(白炙燈) 100h(螢光燈及放電燈) 穩定時間 5mins(白炙燈) 15mins(螢光燈) 30mins(放電燈) 可替換式啟動器(5000pF 10%)( 5%)弧光開關起動器(glow-switch starter),量測方法( Method of measurement ),Insertion loss Disturbance voltages Radiated electromagnetic disturbances,Insertion loss,Dummy lamp U1(2m

6、V1V) U2 Insertion loss = 20 log(U1/U2)dB,Insertion loss measurement on luminaires for Single-capped fluorescent lamps with integrated starter,Insertion loss measurement on linear and U-type fluorescent lamps luminaires,Configuration of linear and U-type dummy lamps,Disturbance voltages,Mains termina

7、l voltage measurement 0.8m 20% between V-network and terminal a-b 0.8m flexible three-core cable Load and control terminal voltage measurement Light regulation At the mains terminals 9kHz,50kHz,100kHz,160kHz,240kHz,550kHz,1MHz,1.4MHz,2MHz,3.5MHz,6MHz,10MHz,22MHz,30MHz At the load and/or control term

8、inals 160kHz,240kHz,550kHz,1MHz,1.4MHz,2MHz,3.5MHz,6MHz,10MHz,22MHz,30MHz,Measuring arrangements for an Independent light regulating device,transformer or converter,Conical metal housing for self-ballasted fluorescent lamps,Radiated electromagnetic disturbances,Measurement equipment Measurements in three direction Light regulation(built-in or external) Half-load condition Maximum load condition,Test set-up for measuring magnetic field in X,Y and Z direction(frequency range 9kHz and 30MHz),測試判定,電

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论