1、Mass spectrometry for the,chromatographer,LC/MS in Drug Development,Identify unknown peaks to support method development and validation,Characterize degradation products in forced degradation studies and stability samples,Elucidate drug degradation pathway to support excipient selection and formulat

2、ion development,Confirm peak identity for DS and related substances,Support QA issues and NDA,Support Manufacturing process and finished drug products,Features of LC/MS,Advantages:, High sensitivity High selectivity Speed, Combined power of separation and identification Molecular weight and structur

3、e information,Disadvantages:, Some compounds are not ionizable Difficult to identify complete unknowns, Limited structure information compared to NMR,Identification Strategy:,When you start LC/MS analysis. Is the method MS compatible?, Conditions where degradation compounds form Synthetic scheme (By

4、product? Intermediate?) Structure of drug substance,active sites and functional groups,Number of nitrogen atoms, Isotope ratio, Full MS spectrum of unknown: Which is M+H? MS/MS spectra of DS and unknown UV spectra of DS and unknown,LC/MS Analysis Work Request,LC/MS compatible method Confirm Chromato

5、gram Select Ionization Mode ESI vs APCI , (+) vs (-),LC/MS incompatible method Modify HPLC conditions Show Peak Equivalency,Determine MW,MS/MS(n) Study,Isolation/Purification,Proposed Structure NMR Confirmation,Report,No,Confirmation ?,Yes,In-house Synthesis,LC-MS,LC,Interface Extraction of Ion evap

6、oration,Mass Analyzer,Detector,The analyte from or ionization.,The solvent,Fragmentation,LC Separation of the mixture of analytes Interface Separation of the analyte from the solvent MA (mass analyzer) separation of the analyte molecular ion and fragments according to their mass to charge ratio,Infu

7、sion MS,MicroTee,MS,LC,100 l/min,pump 1 l/min Sample solution Sample in continuous flow No sample injection No LC separation MS spectrum obtained over an given time Improved S/N due to the average of multiple spectra Select LC flow to assist ionization,-4,Basic Electrospray Schematic N,760 Torr,1 To

8、rr,10-2 10-5 Torr,10-5 Torr,Ion optics Formation of gas phase ions from solution phase Richard B. Cole, Electrospray Ionization Mass Spectrometry, Fundamentals Instrumentation and Applications, Wiley Interscience, 1997,ELECTROSPRAY,Factors to consider,Ionic strength,Surface tension of the solvent Vo

9、latility of the solvent,Character of the analyte ions in solution: solvated, ion paired, etc,Mobile phase composition and amount of water pH of the mobile phase,Intensity,Intensity,Confirmation of molecular weight,ESI (+),ESI (-),1.8x107 1.6x107 1.4x107,294.05,7x106 6x106 5x106,292.04,1.2x107 4x106

10、1.0 x107,8.0 x106 6.0 x106 4.0 x106 2.0 x106,3x106 2x106 1x106,0.0 100.00,200.00,300.00,400.00,500.00,600.00,700.00,800.00,0 100.00,200.00,300.00,400.00,500.00,600.00,700.00,800.00,m/z,m/z,1. Effect of instrumental parameters on ESI response,Mobile phase flowrate* Capillary*/corona voltage Fragement

11、or*/cone voltage,All play important roles in analyte ions formation and ionization efficiency,Effect of flow rate on ESI response Dependence of mass analyzed ion intensity of the BH+ ion of protonated cocaine (10-5M) on flow rate. O CH3 O,H3C,N,O O Increasing the flow rate increases droplet size whi

12、ch decreases the yield of gas-phase ions from the charged droplets. - Use shorter columns of same phase and proportionally decrease,flow rate.,P.Kebarle, et.al, Anal.Chem. 1993, 65, 972A,Effect of capillary voltage,G.Valaskovic,J.Murphy, M.Lee, Milestone,development,Formation of small micron sized d

13、roplets is not a problem if flow rate, surface tension are low. An increase of these may make it difficult to for the electric field to produce the desired charged aerosol. The electric field strength can be increased to try to overcome those effects. However if electric field is too high will give

14、rise to electrical discharge and this is detrimental to ES signal. Nebulizing gas can be used to help focus the # of ions transported into vacuum envelope of the mass spectrometer.,0,0,Effect of Cone/Fragmentor Voltage on fragmentation,FB- 25CV +1,FB 60CV+1,TAE226 FB-1 807 (8.225),1: Scan ES+ TAE 22

15、6 FB-2 805 (8.205),1: Scan ES+,100,469.18,4.86e7 100,438.16,5.13e7,25V Single Quad,3:1,DS,60V Single Quad,469.18,3:1 3:1,DS,403.22,%,471.08,937.44,%,372.20,471.08,100.19 155.62,214.09,242.19 255.11,315.23,348.40 434.62,506.91,577.06,652.27 696.09,721.16,813.47 831.58,891.09 941.49,976.06 m/z,99.94 1

16、17.53,193.08,315.61 359.54,491.09 534.26,635.18,720.40,757.50,870.45 913.51 937.57 959.60,m/z,100,200,300,400,500,600,700,800,900,1000,100,200,300,400,500,600,700,800,900,1000,As potential difference (deltaV) between end of capillary (N) and first skimmer (S) is increased the ions are accelerated th

17、rough the background gas, which leads to more collisions.,Effect of experimental parameters on ESI response,A. Dependence of ion intensities on analyte concentration,Concentration effect of tetracycline on the signal intensity,A. Kamel, P.R. Brown, B. Munson, Analytical Chemistry, vol.71, 968-977, 1

18、999,B. Role of solution equilibria and solution-phase chemistry,B,C,ko,A,B,C,ko,k,k1,pKa,k k1,pKa,pH,0,1,2,3,4,5,6,7,pH,Basic compound: pKa=6,Acidic compound: pKa=3,pH = analyte pKa, Analyte is 50% ionized Cs. Horvath, W. Melander, I. Molnar, Anal.Chem. 49 (1977) 142.,Effect of Solution pH (ESI),Var

19、iation of solution pH changes the acid-base equilibrium of an analyte species,Alters the degree of positive/negative charging via protonation/deprotonation,Should get increased intensity with decreasing pH for basic compounds in positive ion mode,Should get increased intensity with increasing pH for

20、 acidic compounds in negative ion mode,However ion-pairing, ion-association may lead to ion-suppression actually causing a decrease in ionization efficiency,There is a critical point at which increase in protonation ceases to increase ionization efficiency for protonated bases.,Effect of organic on

21、the shift of ionization equilibria in the mobile phase.,IbuprofenM-Hs/n,-,Effect of eluent pH 600 500 400 300 200 100 0,2,4,6,8,pH Effect of pH on M-H- negative-ion response of Ibuprofen. Desired pH values were achieved using different combinations of 0.1% formic acid and 0.1% ammonium hydroxide at

22、constant organic composition. Flow injection analysis Y.F. Cheng, Rapid Comm in Mass Spec., 2001; 15; 141-151,ESIEfficiency,Full Scan ESI Efficiency of Antidepressants vs Concentration of Acetonitrile in the mobile phase 4.00E+06 3.20E+06 2.40E+06,1.60E+06 8.00E+05 0.00E+00,Imi Des i Pro Clom,0,20,4

23、0,60,80,100,Pe rce nt Ace tonitrile,Mobile Phase: Analyte Conc: Infusion Rate:,Aqueous/MeCN Aqueous = 1 mMol Ammonium Formate, pH 4.32 with Formic Acid 100 nM/mL 20 uL/min,MSIntensity,H,N,(,Effect of type of acidic modifier on electrospray response Pindolol Pindolol pKa 8.8, TFA,25000000,Pindolol pK

24、a 8.8/AA Pindolol pKa 8.8/propionic,OH,20000000 15000000 10000000 5000000 0,H3C,CH3,NH,O,0,20,40,60,80,100,% MeCN Analyte ion intensity affected by the presence and concentration of other electrolytes 1) Depends on the propensity of ion-association which can lead to formation of neutral species whic

25、h will lead to ion-suppression causing a decrease in ionization efficiency:,CCl3COO-CF3COO-CH3COO-Cl-,Mirza and Chiat, Anal.Chem. 1994, 66, 2898-2904),2) May depend on volatility of acid (bp of acid) Propionic Acetic Formic TFA,Conclusions,The electrospray ion intensity can be enhanced by: Concentra

26、tion of analyte and instrumental parameters Solution phase pH,Type and concentration of acidic modifier or volatile buffer Type and concentration of organic modifier,Gas phase Reactions are important, feasibility depends on,proton affinities of analyte versus modifier in eluent,ESI is a complex proc

27、ess comprises of many different variables,no set of parameters will guarantee large signal intensity,MS Structure elucidation,Basic principle Nitrogen Rule,Isotope ratio (Cl, Br, etc.) Adduct ions,LC/MS,Post column addition (acid or base),MS/MS or CID : from fragments to substructures Hydrogen-Deute

28、rium exchange,Utilization of UV spectra to support MS identification,Other techniques for structure elucidation,Exact MS : Elemental composition & chemical formula GC/MS: EI mass spectrum,NMR or LC/NMR : Detail structure,Calculating Molecular Weight,Three ways to calculate molecular weight Average m

29、ass:,Average atomic weight for each element, (Merck index, DS profile) 12.01115*60+1.00797*122+14.0067*20+.=1443.8857 Monoisotopic (exact) mass:,Exact mass of the most abundant isotope of each element 12.0000*60+1.0078*122+14.0031*20+.=1442.8796 Nominal mass:,Integer nominal mass of the most abundan

30、t isotope of each element 12*60+1*122+14*20+.=1442,Mass defect 1444:1443:1442. This is as good as being a mile off!,ALWAYS use the monoisotopic mass when calculating the molecular weight in mass spectrometry!,Nitrogen Rule, Compounds with an odd number of nitrogen atoms,have an odd molecular weight

31、(1,3,5,7), Compounds with an even number of nitrogen atoms,have an even molecular weight (0, 2,4,6),Positive and Negative Adduct Ions Positive ion detection, M+H+ M+NH4+ M+Na+ M+K+ 2M+H+ 2M+NH4+ 2M+Na+ Negative ion detection M-H- M-H+HOAC-,M+1 M+18 M+23 M+39 2M+1 2M+18 2M+23 M-1 M+59,MeCN= +41 MeOH=

32、 +32, M-H+TFA-,M+113,Distinct molecular ion pattern can be used to determine the molecular weight. H 3 C O,O,H 3 C,O,O,CH 3,OH,CH 3,H N,O,CH 3,H,O,OH,H O,O,O,O,O,O,CH 3,ESI full scan mass spectrum of paclitaxel with mobile phase that contains 2mM ammonium acetate and acetonitrile Kerns, et.al, 1994,

33、 American Chemical Society,Relative Isotope Abundance of Common Elements,ELEMENTS,ISOTOPE,RELATIVE,ISOTOPE,RELATIVE,ISOTOPE,RELATIVE,ABUNDANCE,ABUNDANCE,ABUNDANCE,Carbon Hydrogen Nitrogen,12C 1H 14N,100 100 100,13C 2H 15N,1.11 0.016 0.38,Oxygen Sulfur Chlorine Bromine,16O 32S 35Cl 79Br,100 100 100 1

34、00,17O 33S,0.04 0.78,18O 34S 37Cl 81Br,0.20 4.40 32.5 98.0,Isotope ratios of Chlorine and Bromine,Cl,Cl2,120 100 80 60 40 20 0,100,32.6,120 100 80 60 40 20 0,100,65.3,10.6,M,M+2,M,M+2,M+4,Br,Br2,100 80 60,100,97.9,250 200 150,195,40 20 0,100 50 0,100,95.5,M,M+2,M,M+2,M+4,P.R.Tiller, et.al, J.Chrom.A

35、, 794 (1998) 15 - 25,: Hydroxylation,P.R.Tiller, et.al, J.Chrom.A, 794 (1998) 15 - 25,Using LCMS to determine artifact peaks formed on-column,CF3,CF3,O N,O,CF3,+,H O+H H,O N,O,CF3,OHC,F MW = 503.4,Acidic conditions,H C HO OH,F MW = 521.1,Intensity,Intensity,Intensity,TIC vs. EIC,10000000 8000000 600

36、0000 4000000 2000000,TIC,2,4,6,8,10,12,14,16,18,800000 600000 400000 200000 0,m/z = 522, XIC,2,4,6,8,10,12,14,16,18,5000000 4000000,3000000 2000000 1000000 0,m/z = 504, XIC,2,4,6,8,10,12,14,16,18,Time (min.),Exact Mass- Q-TOF,Trends in Analytical Chemistry, Vol. 22, No. 10, 2003, Imma Ferrer, et.al.

37、,Post column addition,MicroTee,MS,LC,1 ml/min,0.1 ml/min,waste,1% Formic acid,in IPA Sample injection LC separation No impact on LC chromatographic pattern Improve ionization with either acid or base addition after LC column Select appropriate solution to assist ionization,Nitrogen Rule,This rule is

38、 derived from the fact that, perhaps coincidentally, for the most common chemical elements in neutral organic compounds (hydrogen, carbon, nitrogen, oxygen, silicon, phosphorus, sulfur, and the halogens), elements with even numbered nominal masses form even numbers of covalent bonds, while elements

39、with odd numbered nominal masses form odd numbers of covalent bonds, with the exception of nitrogen, which has a nominal (or integer) mass of 14, but has a valency of 3.,It should be noted that the nitrogen rule is only true for neutral structures in which all of the atoms in the molecule have a number of covalent bonds equal to their standard valency (counting each sigma bond and pi bond as a separate covalent bond for the purposes of the calculation). Therefore, the

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论