版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,1,Innova 2000,The system is sold with the following as the base system: Items in Yellow are options LC 3 axis gantry Generator MX 150 X-ray Tube Collimator Digital Detector Omega IV Allows service to retrieve info about usage of system Tool for cust
2、omer to Drive Managerial Decision Making for Productivity How Fast: Exam Time, Time Between Exams, Throughput How Much: Exam Volume, Referral Volume, Study Mix How Good: Benchmarking Within the Department, Within the System, Versus the BEST,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,104,Imag
3、ing Performance Manager Cont,Feature Tracking and Trending Benchmarking Side by side Graphical Comparisons Performance to target alerts Benefit Monitors Performance Patterns Comparison to self and others Visually depicts similarities and differences Identifies when and where “OFF TARGET” Support On-
4、line help Applications Training,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,105,Issues found on H2 M3,The date and time does not transfer to the DDS image / film. Fix: H3 Q104 Auto Positioner doesnt move the “L”. Depends on HW (Motorola board vs Roadrunner). Intermittent crash of DL. Reboot t
5、o fix. Fixed On Demand from OLC 7.5 f/s can be aborted during acq. Prom on C80 board from M4b works or replace with 2-C80 board. Firmware V04 needs to be V06. Zoom stays active with a zoomed sequence or exiting a zoomed QCA. Fix: Dose Export FMI Q303 Ilink wont work with Broadband if the 3rd Etherne
6、t port isnt disabled If Protocol name has unusual characters in the name (- * ) the sequence will not push to the network. Fix: Kevin Rodgers Possible IQ problems if default protocol values have been set at poor settings.,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,106,Other Issues,4F36 issue
7、: Server logs get too large and take too log to back up and system wont boot up Atlas error codes 5000047 and 3400027 are linked to the 4F36 message on the console and the monitor reads X-ray not available; Reset system to recover X-ray; Call Service If the backup procedure during boot takes minutes
8、 to run then most likely you have this scenario happening at your site. Fix is in the Service Pack FMI and VCP M3 (new installed Systems with the DL4 chassis) have the fix in them as well. There is a temp fix for those experiencing these boot issues. Remember this pertains to DL1 and DL2 chassis onl
9、y. The NEW DL4 systems already have the fix.,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,107,Heroic 2 VCP M3 (signed FW804) Forward production only Storage commitment (part of worklist and dose export= admin option Exam data export linked to Worklist (option) Push at patient level Configure A
10、uto Review Configure English measurements Corrected bugs: filled catheter detection wont fail on filled cath but increased imprecision intermittent zoom in review (QCA or Zoomed seq. Is still there) crash DL at exam push gantry autopositioner (L) acquisition date&time DL autostop freeze New HW: DL4
11、RTAC 4 no more C80 boards replaced by DIPB,Innova 2000 Future Scope,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,108,Heroic 2 VCP M4 (FW 48 04) (at risk) Forward production only + FMI on VCP M3 sites Blooming reduction DRM is default (requires engineering to change) Quality of Serv Pack in M4
12、merge of FMI fix into VCP M4 QVA Option DL auto cal for QVA Table rotation feedback for AW Stenosis Analysis and LVA Fixed (message is just displayed saying that table is rotated) Merge quality fixes done on Serv Pack FMI done after VCP M3,Innova 2000 Future Scope,Rev10, 9/14/04, ppayne,GE Confident
13、ial-PROPRIETARY,109,Heroic 2 (M3) Service Pack FMI 11495 (FW 41 04) For installed base (Mandatory) 10 Pilots FW 31, IB kits FW XX04 Corrected bugs: intermittent zoom in review (QCA or Zoomed seq. Is still there) crash DL at exam push gantry autopositioner (L) acquisition date&time on DDS Configure a
14、uto review time Filled catheter detection- QCA new algorithms, wont fail on filled cath but increased imprecision % Fix some error messages Exam data export Dynamic Range Management Preference (no Hyperlink) (2 Options) Standard DRM (default) Blooming Reduction DRM HW failure on F5 while loading new apps SW. Locks DL screen Worklist and PACS issue w/ retrieve IQST Security fix,Innova 2000 Future Scope,Rev10, 9/14/04, ppayne,GE Confidential-PROPRIETARY,110,Today on IB: old DRM only. A specific release with Blooming reduction DRM is available to address CSOs. Heroic
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026事业单位工勤技能-宁夏-宁夏林木种苗工四级(中级工)历年参考题库含答案详解
- 2026事业单位工勤技能-天津-天津电工四级(中级工)历年参考题库含答案详解
- 2026事业单位工勤技能-天津-天津不动产测绘员五级(初级工)历年参考题库含答案详解
- 2026事业单位工勤技能-吉林-吉林广播电视天线工三级(高级工)历年参考题库含答案详解
- 2026事业单位工勤技能-内蒙古-内蒙古林木种苗工一级(高级技师)历年参考题库含答案详解
- 2026事业单位工勤技能-云南-云南管道工一级(高级技师)历年参考题库含答案详解
- 2026事业单位工勤技能-上海-上海仓库管理员五级(初级工)历年参考题库含答案详解
- 高三化学实验部分规范答题模板
- 个人项目述职报告汇编7篇
- 2026陕西检察院书记员招聘笔试真题回忆版
- 高中学生心理安全健康的课件
- 气球反冲小车课件
- 锂电池热失控诱发电弧特性及防护研究进展
- 2025-2026学年江苏省连云港市海宁中学上学期七年级开学考试数学试题
- (正式版)XJJ 090-2018 《电供暖系统应用技术规程》
- 2025浙江金华市永康市综合行政执法局编制外人员招聘12人备考练习题库及答案解析
- 财务电子发票管理办法
- 肺功能报告解读课件
- 《深圳市低空经济产业创新发展实施方案》
- 江苏省苏州市2024-2025学年七年级下学期期末考试数学试卷及答案
- 小学生蜡笔画教学课件
评论
0/150
提交评论