1、KLARI-FUSE2KLARI-FUSE-2with FK1, FK2, FK3 and HI-ProbeStatus April 2009. All mentioned trademarks or brands are property of the corresponding owner. Subject to error and technical changes.DESCRIPTIONThe universal multi-channel millivoltmeter KLARI-FUSE has been developed for use in combination with

2、low- resistance measuring shunts to measure currents in various sections of a vehicles fuse box.At the front of the unit there are eight connectors with precision contacts using which the measuring adapters in the form of special measuring fuses can be connected. The inputs used for voltage measurem

3、ent are each electrically isolated.These connectors also have communication lines. They allow configuration data (such as measuring range, compensation values and so on) to be read out of the connected measuring adapters. The compensation values are taken into consideration when the measured values

4、are calculated. This results in a very high degree of accuracy.ACCESSORIESCurrent probes: To measure the current in defined electric circuits in vehicle fuse boxes, we offer adapters with FK1, FK2 and FK3 plug-in fuses.These adapters allow the measuring circuit to be protected in the ranges 5 to 70

5、A by the original fuse.The high-current probes cannot be protected by fuse as the measuring range goes up to 4800 A.We also offer voltage probes in the ranges 0 to 80 V. Our temperature probes have an integrated PT1000 sensor and are available as a standard and acid- resistant variant.POWER SUPPLY6

6、to 50 V DCExamples for Probe types, measuring ranges and resolutions (given in Gain 100):Probe typeMeasuring RangeResolution/BitResistorLI-Probe 1-0,3.+0,72A0,25 A1 LI-Probe 25 m-12+28,8A10 A25 mFK1 and FK2 10A+/- 10 A21 A12 mFK1 and FK2 20A+/- 20 A50 A5 mHI-Probe120A-300+720 A250 A1 mHI-Probe1200A-

7、3000+7200 A2,5 mA0,1 m*Factory calibration with certificate is available on request (subject to an additional fee).KLARI-FUSE-40 to +130CProbes:KLARI-FUSE: -40 to +85CTemperature range1 V/bit4 V/bit4 V/bit24 V/bitResolution: Resolution: Resolution:Resolution:Resolution: 250 nV/bitResolution: 500 nV/

8、bit+/-0 to 7.5 mV+/-0 to 15 mV+/-0 to 30 mV+/-0 to 120 mV+/-0 to 120 mV-300 to + 720 mV-Status April 2009. All mentioned trademarks or brands are property of the corresponding owner. Subject to error and technical changes.SPECIFICATIONSInputs Max. 8 channels for voltage measurement, potential-free f

9、or:- I probes- U probes and- T probes (PT1000)Resolution+/- 15 bit/measuring range 5 measuring rangesSampling ratesAdditional functions 1 Kanal max. 8000S/sec. 12 chanel max. a. 4000S/sec. 34 chanel max. a. 2000S/sec. 58 chanel max. a. 1000S/secOutputs Time synchronisation of several KLARI-FUSE unit

10、s via master/slave selection (CAN or RS232 interface) Isolated high-speed CAN up to 1 MBaud Terminating resistor can be switched and/or USB-2.0Time base 32,768 Hz resonator 30 s resolutionHousing (LxWxH) Metal housing: 170x115x50 mmPower supply 6 to 50 V DCPower consumption Approx. 200 mA at 12 V DC

11、ConfigurationOperating modes USB-2.0 , using supplied PC software KoWin or Klari-Toolbox 8-channel parallel operation- Autorange over all measuring ranges- Reduction of data rate by means of:- Differential measurement with adjustable value- Limit mode (measured values below the limit are not transmi

12、tted)Insulation voltage 80 V DCProtection class IP65APPLICATIONStatus April 2009. All mentioned trademarks or brands are property of the corresponding owner. Subject to error and technical changes.ITEMS SUPPLIED AS STANDARD KLARI-FUSE module, item no. IMFUS-00001-0000Probes have to be ordered separa

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论