BS-5929-7-1992 ISO-3972-1991.pdf_第1页
BS-5929-7-1992 ISO-3972-1991.pdf_第2页
BS-5929-7-1992 ISO-3972-1991.pdf_第3页
BS-5929-7-1992 ISO-3972-1991.pdf_第4页
BS-5929-7-1992 ISO-3972-1991.pdf_第5页
已阅读5页,还剩7页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

british standard bs 5929-7: 1992 iso 3972:1991 methods for sensory analysis of food part 7: investigating sensitivity of taste licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi bs 5929-7:1992 this british standard, having been prepared under the direction of the agriculture and food standards policy committee, was published under the authority of the standards board and comes into effect on 31 january 1992 bsi 03-1999 the following bsi references relate to the work on this standard: committee reference afc/12 draft for comment 90/53734 dc isbn 0 580 20507 x committees responsible for this british standard the preparation of this british standard was entrusted by the agriculture and food standards policy committee (afc/-) to technical committee afc/12, upon which the following bodies were represented: afrc institute of food research association for consumer research (acre) british food manufacturing industries research association british psychological society campden food and drink research association coffee trade federation ltd. department of trade and industry (laboratory of the government chemist) flour milling and baking research association food and drink federation institute of food science and technology institute of masters of wine joint committee of the milk marketing board and the dairy trade federation ministry of agriculture, fisheries and food royal society of chemistry society of chemical industry society of cosmetic scientists society of dairy technology university of bristol university of reading university of strathclyde amendments issued since publication amd. no.datecomments licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi bs 5929-7:1992 bsi 03-1999i contents page committees responsibleinside front cover national forewordii introduction1 1 scope1 2normative references1 3definitions1 4principle1 5reagents1 6apparatus2 7general test conditions3 8identification of tastes3 9familiarization with the different types of threshold4 10expression of results4 annex a (informative) example of a completed answer form for the identification of tastes5 annex b (informative) example of a completed answer form for the familiarization with different types of threshold6 table 1 specification of stock solutions2 table 2 series of appropriate dilutions for each taste3 table 3 test solutions for the identification of tastes3 publication(s) referred toinside back cover licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi bs 5929-7:1992 ii bsi 03-1999 national foreword this part of bs 5929 has been prepared under the direction of the agriculture and food standards policy committee. it is identical with iso 3972:1991 “sensory analysis methodology method of investigating sensitivity of taste”, published by the international organization for standardization (iso), and in the preparation of which the united kingdom played a full part. a british standard related to iso 385-1:1984 and iso 385-2:1984 is bs 846:1985 “specification for burettes”. burettes complying with bs 846:1985 are technically equivalent to, and may be used in place of, those complying with iso 385-1:1984 and iso 385-2:1984. the technical committee has reviewed the provisions of iso 385-3:1984, to which reference is made in the text, and has decided that they are acceptable for use in conjunction with this part of bs 5929. when iso 5492 is published, it is intended to publish it as a dual-numbered revision of bs 5098. in the meantime, bs 5098:1975 “glossary of terms relating to sensory analysis of food” may be used. textual errors. when adopting the text of the international standard, the textual errors listed below were discovered. they have been marked in the text and have been reported to iso in a proposal to amend the text of the international standard. in the first and second rows of table 1, “crystallized” should read “crystalline”. a british standard does not purport to include all the necessary provisions of a contract. users of british standards are responsible for their correct application. compliance with a british standard does not of itself confer immunity from legal obligations. cross-references international standardcorresponding british standard iso 1042:1983bs 1792:1982 specification for one-mark volumetric flasks (identical) bs 5929 methods for the sensory analysis of food iso 6658:1985part 1:1986 general guide to methodology (identical) iso 8589:1988bs 7183:1989 guide to design of test rooms for sensory analysis of food (identical) summary of pages this document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 6, an inside back cover and a back cover. this standard has been updated (see copyright date) and may have had amendments incorporated. this will be indicated in the amendment table on the inside front cover. licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) bsi 03-19991 introduction much has been learnt about sensory analysis since the publication of the first edition of this international standard (in 1979) which dealt with the determination of sensitivity of taste. it is now recognized that there are no “primary tastes” for assessing the sensitivity of taste of assessors (although sucrose and aspartame are good indicators of sweetness and quinine hydrochloride and caffeine of bitterness). the analysis of sensitivity of taste is no more complete than would be a classification of a group of individuals solely on the basis of their height. as a result, it has been considered useful to introduce the tastes umami (monosodium glutamate) and metallic into this international standard. 1 scope this international standard describes a set of objective tests for familiarizing assessors with sensory analysis. the test methods described can be useful a) to teach assessors to recognize tastes and to distinguish between them (see clause 8), b) to teach assessors to know and to differentiate amongst different types of threshold (see clause 9), c) to make assessors aware of their own sensitivity of taste, and d) to enable test supervisors to carry out a preliminary categorization of assessors. the methods can also be used as a periodic monitor of the sensitivity of taste of assessors who are already members of sensory analysis panels. 2 normative references the following standards contain provisions which, through reference in this text, constitute provisions of this international standard. at the time of publication, the editions indicated were valid. all standards are subject to revision, and parties to agreements based on this international standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. members of iec and iso maintain registers of currently valid international standards. iso 385-1:1984, laboratory glassware burettes part 1: general requirements. iso 385-2:1984, laboratory glassware burettes part 2: burettes for which no waiting time is specified. iso 385-3:1984, laboratory glassware burettes part 3: burettes for which a waiting time of 30 s is specified. iso 1042:1983, laboratory glassware one-mark volumetric flasks. iso 5492:1), sensory analysis vocabulary. iso 6658:1985, sensory analysis methodology general guidance. iso 8589:1988, sensory analysis general guidance for the design of test rooms. 3 definitions for the purposes of this international standard, the definitions given in iso 5492 apply. for the convenience of the users of this international standard, the following definitions are repeated. 3.1 stimulus threshold; detection threshold minimum value of a sensory stimulus needed to give rise to a sensation. the sensation need not be identified 3.2 recognition threshold minimum value of a sensory stimulus permitting identification of the sensation perceived 3.3 difference threshold value of the smallest perceptible difference in the physical intensity of a stimulus 4 principle 4.1 identification of tastes presentation to each assessor of reference substances, in a known order, corresponding to certain tastes, in the form of aqueous solutions of given concentration. after each tasting, identification of the taste by the assessors and recording of their assessments. 4.2 familiarization with the different types of threshold for each taste, presentation of the appropriate reference substance to each assessor, in the form of a series of dilutions of increasing concentration. after each tasting, recording of the results by the assessors. 5 reagents 5.1 water, neutral, tasteless, still and odourless, preferably of known hardness. 1) to be published. licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) 2 bsi 03-1999 the water provided to the assessors for rinsing their mouths shall be identical with that used to prepare the dilutions (5.3). 5.2 stock solutions prepare, in volumetric flasks (6.1), the solutions listed in table 1 from food-grade reference substances. 5.3 dilutions from the stock solutions specified in table 1, prepare a series of dilutions for each taste in accordance with table 2. 6 apparatus 6.1 one-mark volumetric flasks, conforming to iso 1042, clean, dry and of suitable capacity for preparing the stock solutions. 6.2 burettes, conforming to iso 385, preferably having automatic zeroing, for preparing the dilutions. 6.3 vessels, (glasses, beakers), clean, dry and having a capacity of about 50 ml, for presentation of the test solutions. table 1 specification of stock solutions tastereference substanceaconcentration g/l acidcrystallizedd citric acid (monohydrate) mr= 210,14 1,20 bittercrystallizedd caffeine (monohydrate) mr= 212,12 0,54 saltyanhydrous sodium chloride mr= 58,46 4,00 sweetsucroseb mr= 342,3 24,00 umamimonosodium glutamate, c5h8nnao4.h2o mr= 187,13 2,00 metallicciron(ii) sulfate heptahydrate, feso4.7h2o mr= 287,9 0,016 notea quantity of 2 l of stock solution is sufficient for about 20 assessors. a the products used shall be free from impurities which could give interfering tastes. b sucrose solution is unstable and shall be used on the day it is prepared. c the perception “metallic” has been separated from the other tastes since it is an olfactory-gustatory sensation. it is necessary to use a solution recently prepared with neutral or slightly acid water in order to avoid the appearance of a yellow coloration due to oxidation. meanwhile, if a yellow coloration exists, it is necessary to present this solution in sealed opaque containers or under monochromatic light. the perception “metallic” may be modified by the condition of the teeth since certain dental prostheses produce an electrolytic effect. d see national foreword. licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) bsi 03-19993 table 2 series of appropriate dilutions for each taste 7 general test conditions 7.1 test room the tests shall be conducted in a room which complies with the requirements specified in iso 8589. 7.2 general rules the general guidelines given in iso 6658 are applicable for the execution of these tests. it is particularly important that the assessors taste each solution without haste (about 30 s intervals); the assessors take a sufficient amount of solution to allow impregnation of the whole mouth (about 15 ml); the assessors rinse the mouth with water (5.1) after evaluating each taste series; the samples and water are at the same temperature (usually ambient temperature, around 20 c) and that they remain at this temperature throughout the tests. 8 identification of tastes 8.1 test solutions for each taste, choose the dilution indicated in table 3, corresponding to a mixture of equal parts of dilutions d2 and d3 (see table 2). table 3 test solutions for the identification of tastes divide these dilutions between a series of vessels (6.3) (between 9 and 15), repeating certain dilutions and also including one or two vessels containing water (a sample series could thus comprise, for example, two acid, one water, two salty, two bitter, one water, two umami, two metallic, one sweet.) prepare as many sample series as there are assessors. identify all samples with a unique three-digit code known only to the test supervisor. provide each assessor with a jug or bottle of water for rinsing out the mouth. this water shall be identical with that used for the preparation of the dilutions. dilution code acidbittersaltysweetumamimetallic 1 mlg/lmlg/lmlg/lmlg/lmlg/lmlg/lmg/l d15000,605000,275002,0050012,00 5001,005000,008 0 8,0 d24000,484000,223501,403007,20 3500,703500,005 6 5,6 d33200,383200,172450,981804,32 2450,492450,003 9 3,9 d42560,312560,141720,691082,59 1720,341720,002 7 2,7 d52050,252050,111200,48651,56 1200,241200,001 9 1,9 d61640,201640,09840,34390,94840,17840,001 3 1,3 d71310,161310,07590,24230,55590,12590,000 9 0,9 d81050,131050,06410,16140,34410,08410,000 7 0,7 geometrical ratio rr = 0,8r = 0,8r = 0,7r = 0,6r = 0,7r = 0,7 is the quantity of the stock solution taken, in millilitres, for 1 l of final solution; is the concentration of the dilution, in grams per litre; 1 is the concentration of the dilution, in milligrams per litre. reference substanceconcentrationa g/l citric acid0,43 caffeine0,195 sodium chloride1,19 sucrose5,76 monosodium glutamate0,595 iron(ii) sulfate heptahydrate0,00475 a it has been proven by practical tests that the reference substances at the concentrations recommended were detected and recognized by 50 % of novice assessors. licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) 4 bsi 03-1999 8.2 determination present to each of the assessors the vessels containing the test solutions prepared in 8.1, and instruct them to proceed as follows. the assessors sample the contents of each vessel, taking a mouthful (about 15 ml) of each, keeping to the order of presentation and without going back to previously sampled vessels. after each tasting, the assessors shall enter their assessments on an answer form (see annex a) or, where applicable, register them using a computerized system. 9 familiarization with the different types of threshold 9.1 test solutions for each taste, use dilutions d1 to d8 prepared in accordance with table 2 and divide them among the vessels (6.3). introduce randomly within each sample series up to three additional vessels containing dilutions of the same concentration as the preceding vessel; this is to eliminate responses given by deduction. the vessels shall be coded by means of a three-digit number. provide each assessor with a glass and a jug or bottle of water for rinsing the mouth. this water shall be identical with that used for the preparation of the dilutions. 9.2 determination it is recommended that at most three tastes be assessed during any one session, in order to avoid sensory fatigue. meanwhile, it is necessary to repeat the assessment of one or more of the tastes during the group of sessions. carry out the test taste by taste, as follows. present an identified vessel containing water to each of the assessors advising them to rinse the palate between each sample. then present them, in sequence, and in increasing order of concentration, with the sample series of vessels containing the dilutions prepared in 9.1. do not present all the vessels to the assessors at the same time as they might be tempted to start with the highest concentration in order to identify easily the taste being tested. instruct the assessors to sample the contents of each vessel in turn, taking a mouthful of about 15 ml from each. immediately after each tasting, the assessors shall enter on the answer form (see annex b) the absence of sensation or the taste sensations produced, using the following system of notation: instruct the assessors to add a cross each time a difference in concentration is identified, and to write down the name of the known taste underneath the number of the corresponding vessel. before passing on to the assessment of a different taste, the test supervisor shall wait a sufficient time to allow the assessors to rinse the palate and to remove any after-taste. 10 expression of results the test supervisor shall analyse the answer forms and draw up a list of correct and incorrect replies for each assessor. the results shall be judged individually, because each assessor has a personal type of sensitivity, and this sensitivity may vary with time and may improve noticeably following training. 0no perceived impression xperceived taste xx, xxx, xxxx, etc.identified difference in concentration licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) bsi 03-19995 annex a (informative) example of a completed answer form for the identification of tastes code no. of vesselstaste not identified acidbittersaltysweetumamimetallic 134x 137x 245x 456x 367x 129x 769x 931x 259x 368x 184x place a cross in the appropriate column. licensed copy: sheffieldun sheffieldun, na, mon dec 04 15:03:08 gmt+00:00 2006, uncontrolled copy, (c) bsi iso 3972:1991(e) 6 bsi 03-1999 annex b (informative) example of a completed answer form for the familiarization with different with types threshold order of presentation of vessels 1st2nd3rd4th5th6th7th8th9th10th11th code no.water320216432109307542875650259129372 answers000xxxxxxxx bitter xxxxxxx xxxx xxxxx xxxxx notation:0no perceived impression xperceived taste xx, xxx, xxxx, etc.identified difference in concentration (add a cross each time a difference in concentration is identified) when the taste is identified, write its

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论