ISO-5832-3-1996.pdf_第1页
ISO-5832-3-1996.pdf_第2页
ISO-5832-3-1996.pdf_第3页
ISO-5832-3-1996.pdf_第4页
ISO-5832-3-1996.pdf_第5页
已阅读5页,还剩2页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

b 4853903 0b56957 900 international standard is0 5832-3 third edition 1996-07-01 implants for surgery - metallic materials - part 3: wrought titanium 6-aluminium 4-vanadium alloy implants chirurgicaux - produits base de mtaux - partie 3: alliage forger base de titane, daluminium 6 et de vanadium 4 this material is reproduced from is0 documents under international organization for standardization (iso) copyright license number ihsllccl1996. not for resale. no part of these is0 documents may be reproduced in any form, electronic retrieval system or otherwise, except as allowed in the copyright law of the country of use, or with the prior written consent of is0 (case postale 66,1211 geneva 20, switzerland, fax +41 22 734 10 799, ihs or the is0 licensork members. reference number is0 5832-3:1996(e) r 4851703 0656758 8463 e is0 5832-3:1996(e) foreword is0 (the international organization for standardization) is a worldwide federation of national standards bodies (is0 member bodies). the work of preparing international standards is normally carried out through is0 technical committees. each member body interested in a subject for which a technical committee has been established has the right to be rep- resented on that committee. international organizations, governmental and non-governmental, in liaison with iso, also take part in the work. is0 collaborates closely with the international electrotechnical commission (iec) on all matters of electrotechnical standardization. draft international standards adopted by the technical committees are circulated to the member bodies for voting. publication as an international standard requires approval by at least 75 % of the member bodies casting a vote. international standard is0 5832-3 was prepared by technical committee isottc 150, implants for surgery, subcommittee sc 1, materials. this third edition cancels and replaces the second edition (is0 5832-3:1990), which has been technically revised. is0 5832 consists of the following parts, under the general title implants for surgery - metallic materials: - - part 2: unalloyed titanium - - - - - part i: wrought stainless steel part 3: wrought titanium -aluminium 4-vanadium alloy part 4: cobalt-chromium-molybdenum casting alloy part 5: wrought cobalt-chromium-tungsten-nickel alloy part 6: wrought cobalt-nickel-chromium-molybdenum alloy part 7: forgeable and cold-formed cobalt-chromium-nickel-molyb- denum-iron alloy part 8: wrought cobalt-nickel-chromium-molybdenum-tungsten-iron alloy - o is0 1996 all rights reserved. unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. international organization for standardization case postale 56 ch-1 21 1 genve 20 switzerland printed in switzerland ii -,-,- 0 is0 4851903 ob5b759 783 is0 5832-3:1996(e) - - - - part 9: wrought high nitrogen stainless steel part 7 o: wrought titanium 5-aluminium 2,5-iron alloy part 7 7: wrought titanium 6-aluminium 7-niobium alloy part 7 2: wrought cobalt-chromium-molybdenum alloy i 111 -,-,- is0 5832-3:1996(e) = 4853703 0656760 4t5 is0 introduction no known surgical implant material has ever been shown to cause absol- utely no adverse reactions in the human body. however, long-term clinical experience of the use of the material referred to in this part of is0 5832 has shown that an acceptable level of biological response can be expected, when the material is used in appropriate applications. iv -,-,- 4851903 qbcib9b1 331 w element i international standard o is0 compositional limits % (m/m) is0 5832-3:1996(e) alu minium vanadium iron oxygen carbon nitrogen hydrogen tita nium implants for surgery - metallic materials - 5,5 to 6,75 3,5 to 4,5 0,3 max. 0.2 max. 0,08 max. 0,05 max. 0,015 max.1) balance part 3: wrought titan i um 6-a i u m i ni um 4-va nad i u m a i i oy 1 scope this part of is0 5832 specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (ti &ai 4-v alloy) for use in the manufacture of surgical implants. note 1 the mechanical properties of a sample obtained from a finished product made of this alloy may not necess- arily comply with the specifications given in this part of is0 5832. 2 normative references the following standards contain provisions which, through reference in this text, constitute provisions of this part of is0 5832. at the time of publication, the editions indicated were valid. all standards are subject to revision, and parties to agreements based on this part of is0 5832 are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. members of iec and is0 maintain registers of currently valid international standards. is0 6892: 1984, metallic materials - tensile testing. is0 7438:1985, metallic materials - bend test. ettc1) publication 2, 1979, microstructural standards for a + p titanium alloy bars2). 1 ) european titanium producers technical committee (ettc) 3 chemical composition the heathgot analysis of a representative sample of the alloy when determined in accordance with clause 6 shall comply with the chemical composition specified in table i . note2 ingot analysis may be used for determining all chemical requirements except hydrogen. the analysis of hydrogen shall be carried out after the final heat treatment and final surface treatment. requirements for the major and minor elemental constituents for titanium 6-al u mi n i um 4-va nad i u m alloy are listed in table i. table 1 - chemical composition 2) available commercially from: deutsche titan gmbh, essen, germany and imi-titanium ltd., birmingham, uk. this infor- mation is given for the convenience of users of this part of is0 5832, and does not constitute an endorsement by is0 of these products. 1 is0 5832-3:1996(e) proof stress of percentage elongation fracture) tensile strength nonproportional elongation after form of alloy rm rp0.2 a min min min m pa m pa sheet and strip 860 780 8 ba 13) 860 780 10 4853983 0b5b%b2 278 e mandrel diameter for bend test 10 t2) not applicable is0 4 microstructure the microstructure, when examined as indicated in table 3, shall be alpha + beta globular, and shall correspond to photomicrographs ai to a9 in ettc publication 2 for annealed material. 5 mechanical properties 5.1 tensile the tensile properties of the alloy, when tested in accordance with clause 6, shall comply with the values specified in table 2. should any of the test pieces not meet the specified requirements, or should they break outside the gauge limits, two further test pieces representative of the same batch shall be tested in the same manner. the alloy shall be deemed to comply only if both additional test pieces meet the specified requirements. note 3 however, the manufacturer may re-heat-treat the material and resubmit it for testing in accordance with this part of is0 5832. in this case, all parts should be heat- treated in the same fashion. 5.2 bending titanium alloy sheet and strip, when tested in ac- cordance with clause 6, shall not show any cracking on the outside surface of the test piece. 6 test methods the test methods used in determining compliance with this part of is0 5832 shall be those given in table 3. representative test pieces for the determination of mechanical properties shall be prepared in

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论