水表通讯指令.doc_第1页
水表通讯指令.doc_第2页
水表通讯指令.doc_第3页
水表通讯指令.doc_第4页
全文预览已结束

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

水表通讯协议1. Self zero 5ACommand: 55 31 01 02 5A 61 73 00 7C2. Old slope 2F Command: 55 31 05 04 2F CE 66 05 00 61 66 slope=2.11(?)3. Cal factor 54 0factor2Command: 55 31 03 02 54 B4 28 D7 00 factor=0.318 55 31 03 02 54 58 29 D7 00 factor=0.323 55 31 03 02 54 78 29 D7 00 01 FF factor=0.324 55 31 03 02 54 99 29 D7 00 factor=0.325 4. Dump 44Command: 55 31 01 01 445. Version(Checksum) 56Command 55 31 01 02 56 61 73 86 4C6. Battery Calibrate 59Command: 55 31 01 01 59 61 73 797. 100series pulse scale 41Command: 55 31 05 04 41 98 81 00 00 61 668. Vout Calibration 4D(100serial)Command:55 31 03 02 4D 00 80 61 669. Enter zero 45 -32767factor32768Command: 55 31 03 02 45 01 80 61 73 01 80 factor=180为结束符,factor必须为整数。10. Serial Number 53Command: 55 31 0D 0C 53 02 30 39 31 32 31 38 31 32 33 34 35 57 10 00 3511. Old reboot 42Command: 55 31 01 00 42 61 7312. Old unlock 2ACommand: 55 31 01 00 2A 61 7313. Old lock 4CCommand: 55 31 01 01 4C 61 6614. Set cutoff 55 (0factor65535)Command: 55 31 03 02 55 30 00 61 6615. 300serial pulse scale 50 High Low1000ppl100ppl10ppl/1000ppg1ppl/100ppg0.1ppl(10lpp)/10ppg0.01ppl(100lpp)/1ppg0.001ppl(1000lpp)/0.1ppg(10gpp)1000pplEAEAEBEAE8EAE9EA0AEA0B EA0C EA 100pplEAEBEBEBE8EB E9EB 0AEB0BEB0C EB10ppl/1000ppgEAE8EBE8E8E8E9E80AE80BE80CE81ppl/100ppgEAE9EBE9E8E9E9E90AE90BE90CE90.1ppl(10lpp)/10ppgEA0AEB0AE80AE90A0A0A0B0A0C0A0.01ppl(100lpp)/1ppgEA0BEB0BE80BE90B0A0B0B0B0C0B0.001ppl(1000lpp)/0.1ppg(10gpp)EA0CEB0CE80CE90C0A0C0B0C0C0Cexample 55 31 03 02 50 0C EA 61 73 0C EA) 设置高脉冲速度为:1000ppl,低脉冲速度为:0.001ppl16. Prop adjust 43 (-factor+)Command: 55 31 03 02 43 01 00 61 73 01 00 系数=1;此系数在使用过程中取整数。17. Debug on(obsolete) 4FCommand: 55 31 01 01 4F 61 6618. Debug off 4DCommand: 51 31 01 01 4D 61 6619. set 4mA value 34 (0factor1)Command: 55 31 03 02 34 EE 05 61 6620. mA Calibration 49 (0factor1)Command: 55 31 03 02 49 A8 61 66 21. Configuration options 46Command: 55 31 03 02 46 FF 2F 61 66 所有选项均置true, 55 31 03 02 46 FF 0F 61 66 除了最后一个选项为False外,其他均为true。选项包括:Fast pulse(300)Singleddir/gallonsDispense/IS heat(100/300)Reverse enable(100)Ser Prop/heat ON (100/300)Disp hold/reset(100/300)Standby/prop limit(300/100)LockDebug modePLASH repairForce rebootFCT(300 batt 100 Vout)TEST MODE: Wide ramp range22. 100 Series fixed ppl 41 Command: 55 31 05 04 41 98 81 01 00 61 66 2000ppl 55 31 05 04 41 98 81 02 00 61 66 1000ppl 55 31 05 04 41 55 AC 02 00 61 66 752ppl 55 31 05 04 41 98 81 04 00 61 66 500ppl 55 31 05 04 41 98 81 08 00 61 66 250ppl 55 31 05 04 41 98 81 0A 00 61 66 200ppl 55 31 05 04 41 FE 8F 0A 00 61 66 180ppl23. Low flow cal 74 (0factor2)Command: 55 31 03 02 74 00 80 61 73 00 80 factor=1 55 31 03 02 74 00 C0 61 73 00 C0 factor=1.5 55 31 03 02 74 99 99 61 73 99 99 factor=1.224. High flow offset 57 (0factor65536)Command: 55 31 03 02 57 02 00 61 73 02 00 offset=2.0 55 31 03 02 57 00 00 61 73 00 00 offset=0.5 55 31 03 02 57 01 00 61 73 01 00 offset=1.5Offset 在实际使用过程中应取整数,低位在前高位在后。25. Low flow offset 77 ( 0offset65536)Command: 55 31 03 02 77 00 00 61 73 00 00 offset=0.5Offset 在实际使用过程中应取整数26. Changeover 4C ( 0offset65536)Command: 55 31 03 02 4C 00 00 61 73 00 00 change over=0.5Command: 55 31 03 02 4C 01 00 61 73 01 00 change over=1.5Command: 55 31 03 02 4C 0C 00 61 73 0C 00 change over=12Changeover 在实际使用应取整数27. Toggle pulse speed 4FCommand: 55 31 01 01 4F 61 6628. Nudge 4ECommand: 55 31 01 01 4E 61 6629. Lower flow cal factor 4A (0factor2)Command: 55 31 03 02 4A CC EC 61 73 CC EC factor=1.85 55 31 03 02 4A 00 A0 61 73 00 A0 factor=1.2530. Lower flow off

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论