



全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
GZLH.IHP (All Mesh Sizes)MSDS NO: 02Revision Date: August 22, 2013Material Safety Data SheetSECTION I - Product and Company IdentificationTrade Name:Ceramic ProppantSynonym(S):Ceramic Proppant; Semi-Crystalline Alumina SilicateChemical Family:AluminosilicateManufacturer:Shandong Kerui Petroleum Equipment CO.,LTD, ShanDong Province, ChinaPhone: 86mergency Phone:8624-Hour)FAX:+86-546-8179681SECTION II - Composition/Information on IngredientsIngredientsCAS NumberConcentrationClassificationR-PhrasesCorundum1302-74-540-60%Not ClassifiedNot assignedMullite1302-93-840-60%Not ClassifiedNot assignedSECTION III Physical/Chemical CharacteristicsBoiling Point:Not applicableMelting Point:Not applicableVapor Density(Air=1):Not applicableVapor Density:Not applicableVapor Pressure(mm Hg):Not applicable%Solubility In Water:Insoluble at 20%Solubility In sea Water:Insoluble at 20Specific Gravity(H2O=1):3.20 to 3.45Bulk Density:118 lb/cu.ft.Biodegradability:Not applicableEvaporation Rate:Not applicable (Butyl Acetate=1)Appearance:Gray to Beige Spherical PelletsOdor:OdorlesspH:NeutralVOC:NoneSECTION IV Health Hazard InformationHazardous Ingredient InformationHMIS RatingHealth:1.(slight)Flammability:0.(Minimal)Reactivity:0.(Minimal)Chronic:1.(slight)Potential Health EffectsInhalation:Prolonged exposure to dusts may cause respiratory tract irritation. Ingestion:NO known adverse effects.Eye Contact:May cause irritation on prolonged or repeated contact. Skin Contact:May cause irritation on prolonged or repeated contact.Special Protection:See Section IXSECTION V Emergency and First Aid MeasuresInhalation:Remove to fresh air. If irritation persists, call a physician.Ingestion:Procedures normally not needed. Seek medical attention if large quantities are ingested.Eye Contact:Immediately flush eyes with large amounts of water. Get medical attention if irritation persists.Skin Contact:Flush with plenty of water. If irritation persists, call a physician.SECTION VI Fire Fighting MeasuresFlash Point:Not applicableLower Explosion Limit:Not applicableUpper Explosion Limit:Not applicableAuto ignition Temperature:Not applicableSpecial Fire Fighting Procedures: This material does not give a flash point by conventional test methods. Use extinguishing agent suitable for type of surrounding fire.SECTION VII Accidental Release MeasuresSpill Procedures:Dust suppressing cleaning methods such as wet sweeping or vacuuming should be used to clean the work area. If vacuuming is used the vacuum must be equipped with a HEPA filter. Compressed air or dry sweeping should not be used for cleaning. Dust suppressing compounds may be used to clean up light dust. Use wet sweeping or a dust suppressant where sweeping is necessary.Release into Air:Prevent release of airborne particulates where possible. Not a regulated hazardous substance. See section IX for appropriate engineering controls.Release into Water:Release into water is not appropriate. Not a regulated hazardous substance. Landfill dusts and debris consistent with local regulations.SECTION VIII Handling and StorageStorage: These materials are stable and may be stored in a dry place indefinitely. Physical abrasion may produce small amounts of respirable dusts.Normal Use: Materials are stable under normal use and are not expected to produce significant hazardous by-products or emissions.SECTION IX Exposure Controls / Personal ProtectionExposure Limits:INGREDIENTSOSHA PEL-TWAACGIH-TWA TLVCorundum15mg/m3 (Total)5mg/m3 (Respirable)10mg/m3 (Total)3mg/m3 (Resp)Mullite15mg/m3 (Total)5mg/m3 (Respirable)10mg/m3 (Total)3mg/m3 (Resp)Engineering Controls: Use dust suppression controls. Local exhaust ventilation, point of generation dust collection, and/or down-draft work stations to minimize airborne dust generation are recommended when machining product.Respiratory Protection: Use appropriate protection pursuant to OSHA 29CFR 1910.134 and 29CFR 1926.103. The following information is provided as a guide and reflects industry recommendations for control of dust.Skin Protection: Wear gloves, head coverings, and full body clothing to prevent skin irritation. Disposable clothing may be used. Store work clothes and street clothes separately.Eye Protection: Wear safety glasses or chemical goggles to prevent eye contact. Do not wear contact lenses unless chemical goggles are also worn. Do not touch eyes with soiled body parts or materials. Have eye washing facilities readily available where eye contact can occur.SECTION X Stability and ReactivityStability: Materials are stable.Chemical Incompatibilities:Powerful oxidizers; fluorine, chlorine trifluoride, manganese trioxide, oxygen difluoride, etc.Hazardous Decomposition Products: NoneHazardous polymerization:Not ApplicableSECTION XI ToxicologyEpidemiology: N/AToxicology: N/ASECTION XII Ecological InformationEcotoxicological Information:No information available.Distribution: Aluminum oxide and silica are naturally occurring and are widely distributed in igneous rock. Secondary deposits in sedimentary rock may be found.Chemical Fate Information:The relative inertness of these materials indicates that they may be highly persistent in the environment. No information regarding any negative effects of this persistence has been noted.SECTION XIII Disposal InformationDisposal: Consult with local, state and federal regulations. In most cases these materials may be land filled safely.Hazardous Waste Classification:Subject to SARA Title III Notification.Empty Containers: Empty containers may contain product dust or residue. Do not re-use.Disposal regulations vary. Consult with all applicable regulations prior to disposal.SECTION XIV Transportation InformationNot regulated hazardous substances, no specific regulations apply.SECTION XV Regulatory InformationSARA TITLE IIISection 302:NoneSection 312: NoneSection 313:NoneToxic Substance Control Act (TSCA): N/ACERCLA Reportable Quantity:NoneClean Air Amendments-Hazardous Air Pollutants: NoneCalifornia State Proposition 65: N/ASECTION XVI OtherThe information contained herein is based on data considered to be accurate as of the preparation or revision date. It is provided in good faith and in compliance with state and federal regulations. No warranty
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 液压闸门维修施工方案(3篇)
- 校友节活动策划方案范文(3篇)
- 广告项目施工方案书(3篇)
- 弧形楼板施工方案(3篇)
- 论语考试题库及答案解析
- 兼职会计考试题库及答案
- 北京市门头沟区2023-2024学年八年级下学期期末质量监测语文考试题目及答案
- 北京市门头沟区2023-2024学年八年级上学期期末质量监测道德与法制考题及答案
- 新兵体检问答题目及答案
- 小学专业考试题目及答案
- 人民医院整形外科临床技术操作规范2023版
- 脚手架搭拆施工方案
- 高等教育新论复习提纲-czy
- 汽车风窗刮水器机构设计
- 重庆某广场高边坡喷锚支护施工方案(脚手架设计)
- 用友ERP沙盘大赛推演工具表(模板)
- 传染病学总论(英文稿)
- 教师师德师风专题培训讲座《润物细无声》
- GB/T 5456-2009纺织品燃烧性能垂直方向试样火焰蔓延性能的测定
- GB/T 5118-2012热强钢焊条
- 老年人居家适老化改造需求评估表
评论
0/150
提交评论