




已阅读5页,还剩36页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
DCX光纤交换机初始化配置微码升级 由于新到的交换机与环境中使用的交换机版本有所区别,因此在,交换机上架前,需先对其进行版本升级至v6.4.2,从而与生产环境匹配。具体升级操作过程见附件:Brocade交换机微码升级操作手册。准备部分1、新交换机预先配置a) 修改交换机名字 用switchname命令进行相应交换机名字的定义。switchname NFDXSN21-L1chassisname NFDXSN21-L1bannerset any unauthorized access is illegal! Contact:9350bannershowtimeout 30b) 交换机IP地址并对管理端口配置百兆全双工用ipaddrset命令进行IP地址的设置NFDXSN21-L1:admin ipaddrset -chassisEthernet IP Address :Ethernet Subnetmask :NFDXSN21-L1:admin ipaddrset -cp 0Host Name cp0:Ethernet IP Address 05:Ethernet Subnetmask :Gateway IP Address 54:NFDXSN21-L1:admin ipaddrset -cp 1Host Name cp1:Ethernet IP Address 05:Ethernet Subnetmask :Gateway IP Address 54:NFDXSN21-L1:admin ifModeSet eth0 /Active CP Auto-negotiate (yes, y, no, n): yes n Force 100 Mbps / Full Duplex (yes, y, no, n): yes NFDXSN21-L1:admin ifmodeset eth0 /Standby CPAuto-negotiate (yes, y, no, n): yes nForce 100 Mbps / Full Duplex (yes, y, no, n): no yForce 100 Mbps / Half Duplex (yes, y, no, n): no nForce 10 Mbps / Full Duplex (yes, y, no, n): no nForce 10 Mbps / Half Duplex (yes, y, no, n): no nCommitting configuration.done.交换机配置DomainID、添加端口描述、disable ISL、disable 交换机用configure命令设置NFDXSN21-L1的DomainID (出厂是1),adminswitchdisable change domain ID21adminconfigureConfigure. Fabric parameters (yes, y, no, n): no y Domain: (1.239) 1 21Insistent Domain ID Mode (yes, y, no, n): no yAdminswitchenable检查Principal Selection Mode,并配置NTP/SYSLOG 查看是否为Principal Selection Mode: DisableNF12SN81_N1:checklist fabricprincipal -qPrincipal Selection Mode: DisableNF12SN81_N1:checklist fabricprincipal 1(强制设成fabricprincipal)NTP配置tsclockserver “;XX.XX.XX.XX”tsTimeZone +8date mmddhhmmyysyslog配置syslogdIpAdd 1syslogdIpAdd 2syslogdIpAdd 4syslogdfacility l 7网管配置1)snmp配置前提条件:(a)交换机支持snmp的相关命令;(b)开通交换机与网管服务器之间的snmp访问策略。通过命令snmpconfig -set accessControl可以配置网管SNMP只读服务器的地址。在进行SNMP配置时,目的IP地址应为五台网管服务器的地址1、12、14。配置命令: snmpconfig -set accessControl输入ip后输入F(ro)表示只读 SNMP access list configuration: Access host subnet area in dot notation: 1 Read/Write? (true, t, false, f): truef Access host subnet area in dot notation: 2 Read/Write? (true, t, false, f): truef Access host subnet area in dot notation: 4 Read/Write? (true, t, false, f): true f Access host subnet area in dot notation: Read/Write? (true, t, false, f): true f Committing configuration.done.验证是否配置成功: snmpconfig -show accessControlSNMP access list configuration:Entry 0: Access host subnet area 1 (ro)Entry 1: Access host subnet area 2 (ro)Entry 2: Access host subnet area 4 (ro)Entry 3: No access host configured yetEntry 4: No access host configured yetEntry 5: No access host configured yet通过命令snmpconfig -set snmpv1配置snmp为v1版本,并配置snmp只读community字符串。配置命令: snmpconfig -set snmpv1SNMP community and trap recipient configuration:Community (rw): Secret C0de Trap Recipients IP address : Community (rw): OrigEquipMfr Trap Recipients IP address : Community (rw): private Trap Recipients IP address : Community (ro): public NFR99OTrap Recipients IP address : Community (ro): common Trap Recipients IP address : Community (ro): FibreChannel Trap Recipients IP address : Committing configuration.done.注:数据中心(北京)只需敲入BFR990,其它回车默认。验证是否配置成功: snmpconfig -show snmpv1SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) No trap recipient configured yet Community 2: OrigEquipMfr (rw) No trap recipient configured yet Community 3: private (rw) No trap recipient configured yet Community 4: NFR99O (ro) No trap recipient configured yet Community 5: common (ro) No trap recipient configured yet Community 6: FibreChannel (ro) No trap recipient configured yet 2)AAA管理前提条件:(a)设备版本推荐是v6.4.0b以后的;(b)开通交换机与ACS服务器之间的Radius防火墙策略;(c)Virtual Fabric功能没有被关闭。(1)在SAN交换机上通过aaaconfig命令配置Radius认证服务器地址。配置命令:Fabric A交换机aaaconfig -add 1 -conf radius -s password -a papaaaconfig -add 2 -conf radius -s password -a papaaaconfig -authspec radius;local -backupFabric B交换机aaaconfig -add 1 -conf radius -s password -a papaaaconfig -add 2 -conf radius -s password -a papaaaconfig -authspec radius;local backup验证是否配置成功: aaaconfig -showPosition : 1Server : XX.1.115.YYPort : 1812Secret : passwordTimeout(s) : 3Auth-Protocol: PAPPrimary AAA Service: RADIUSSecondary AAA Service: Switch database as backup请注意:针对48000、DCX和DCX-4S交换机,交换机使用Active CP的固定IP地址向Radius服务器发送请求,为今后认证方便,请将每台交换机的3个IP地址都加为Radius服务器的客户端,以便在发生CP切换后,服务器还可以继续认证。关于如何设置Radius服务器,请参考北中心的配置文档。3)Fabric Watch管理启用Fabric Watch可以通过手工定制实现对设备状态(包括端口、机箱、电源、操作系统等)的监控。具体的监控内容包括:设备硬件状态(Power supplies、Temperatures、Fans、WWN servers、CP、Blades、Flash、ports、SFP发光功率等)、性能指标(端口Rx/Tx performance等)、端口连接状态(如link loss、link reset、link failure、state change、CRC error、收发光功率、invalid word、C3TX_TO)等。SAN交换机可以在检测到上述监控对象故障时,实时产生告警日志,将交换机各种中间状态的变化写到syslog里(syslog的信息量会大),并通过syslog发到网管系统进行展现。实施SAN交换机Fabric Watch的前提条件:(a)通过命令licenseshow,检查是否存在Fabric Watch License。如果不存在Fabric Watch License,暂不实施Fabric Watch的管理。licenseAdd R9QyyQy9zbgAR(b)已配置syslog的服务器地址。(c)已配置网管SNMP只读服务器的地址,已配置snmp为v1版本,并配置snmp只读community字符串。(d)已在Principal交换机上配置时钟源。(e)需提前在访问SAN交换机fabricwatch的PC机上安装正确的java软件版本(注:不同的存储交换机及版本所需的java版本会有所不同,可根据提示到java官方网站自行下载)。(f)各单位的存储环境不同,需要关注的交换机阀值会有所不同,同时不同类型SAN交换机的Fabric Watch界面也有细微的差异。首先在IE界面通过http方式访问SAN交换机地址,输入用户名和密码后,进入管理界面。A)F_Port/FL_Port配置因可能发生SAN交换机或对端设备异常,连接服务器、盘机、带机的光纤线老化等突发故障的现象,同时也可能存在端口流量过大而引发交换性能效率降低的现象,故在运维过程中需要通过Fabric Watch对交换机及端口的状态进行预判,及早发现相关问题。1)、配置invalid word、C3TX_TO、link loss、link failure、link reset、state change为了监控链路异常现象,请按下列图形的数字标识顺序进行invalid word参数的配置,配置方法是将threshold的上限(High threshold)设为40,下限(Low threshold)设为25。portthconfig -set fop-port -area ITW -lowthreshold -value 25 -buffer 0portthconfig -set fop-port -ar ITW -highthreshold -value 40 -trigger above -action raslogportthconfig -apply fop-port -area ITW -action_level cust -thresh_level custportthconfig -show fop-port -area ITW为了监控链路异常现象,请按下列图形的数字标识顺序进行link loss参数的配置,配置方法是在阀值配置(Threshold Configuration)中,将时间间隔(Time Base)选定为每分钟(Minute),其上限(High Boundary)为0,下限(Low Boundary)为0;同时在报警配置(Alarm Configuration)中,勾选Above所在行中的ERROR_LOG和SNMP_TRAP。为了监控端口同步状态、光信号丢失、端口状态变化的现象,按上述方法,将C3TX_TO、link failure、link reset、state change的参数配置成与link loss相同的参数。具体配置如下:portthconfig -set fop-port -area C3TX_TO -highthreshold -value 5 -trigger above -action raslog -buffer 0portthconfig -apply fop-port -area C3TX_TO -action_level cust -thresh_level custportthconfig -show fop-port -ar C3TX_TOportthconfig -set fop-port -area LOS -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply fop-port -area LOS -action_level cust -thresh_level custportthconfig -show fop-port -ar LOSportthconfig -set fop-port -area LF -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply fop-port -area LF -action_level cust -thresh_level custportthconfig -show fop-port -ar LFportthconfig -set fop-port -area LR -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply fop-port -area LR -action_level cust -thresh_level custportthconfig -show fop-port -ar LRportthconfig -set fop-port -area ST -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply fop-port -area ST -action_level cust -thresh_level custportthconfig -show fop-port -ar ST2)、配置Rx/Tx performance此项目通过Bottleneckmon Detection来监控,设置congestion的阀值为80%。3)、配置CRC error为了监控端口CRC错误,请按下列图形的数字标识顺序进行Invalid CRCs参数的配置,配置方法是在阀值配置(Threshold Configuration)中,将时间间隔(Time Base)选定为每分钟(Minute),其上限(High Boundary)为5,下限(Low Boundary)为0;同时在报警配置(Alarm Configuration)中,勾选Above所在行中的ERROR_LOG和SNMP_TRAP。 具体配置如下:portthconfig -set fop-port -ar CRC -lowthreshold -value 5 -buffer 0portthconfig -set fop-port -ar CRC -highthreshold -value 20 -trigger above -action raslogportthconfig -apply fop-port -area CRC -action_level cust -thresh_level custportthconfig -show fop-port -area CRCB) E_Port配置为判断交换机互联端口问题,可参考上一章节的F_Port/FL_Port配置,配置E_Port的invalid word、C3TX_TO 、link loss、link failure、link reset、state change参数、Rx/Tx performance参数和Invalid CRCs参数。具体配置如下:portthconfig -set e-port -ar CRC -lowthreshold -value 5 -buffer 0portthconfig -set e-port -ar CRC -highthreshold -value 20 -trigger above -action raslogportthconfig -apply e-port -area CRC -action_level cust -thresh_level custportthconfig -show e-port -area CRCportthconfig -set e-port -ar ITW -lowthreshold -value 25 -buffer 0portthconfig -set e-port -ar ITW -highthreshold -value 40 -trigger above -action raslogportthconfig -apply e-port -area ITW -action_level cust -thresh_level custportthconfig -show e-port -area ITWportthconfig -set e-port -area C3TX_TO -highthreshold -value 5 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area C3TX_TO -action_level cust -thresh_level custportthconfig -show e-port -ar C3TX_TOportthconfig -set e-port -area LOS -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area LOS -action_level cust -thresh_level custportthconfig -show e-port -ar LOSportthconfig -set e-port -area LF -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area LF -action_level cust -thresh_level custportthconfig -show e-port -ar LFportthconfig -set e-port -area LR -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area LR -action_level cust -thresh_level custportthconfig -show e-port -ar LRportthconfig -set e-port -area ST -highthreshold -value 0 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area ST -action_level cust -thresh_level custportthconfig -show e-port -ar STportthconfig -set e-port -ar RX -highthreshold -value 80 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area RX -action_level cust -thresh_level custportthconfig -show e-port -ar RXportthconfig -set e-port -ar TX -highthreshold -value 80 -trigger above -action raslog -buffer 0portthconfig -apply e-port -area TX -action_level cust -thresh_level custportthconfig -show e-port -ar TXC) fabric配置为了监控fabric中组网设备互联端口,请按下列图形的数字标识顺序进行E_Port Down参数的配置,配置方法是在阀值配置(Threshold Configuration)中,将时间间隔(Time Base)选定为每分钟(Minute),其上限(High Boundary)为0,下限(Low Boundary)为0;同时在报警配置(Alarm Configuration)中,勾选Above所在行中的ERROR_LOG和SNMP_TRAP。其它fabric配置(如fabric reconfigure、domain id changes、segmentation、zone changes、fabric logins、sfp state changes)保持系统默认参数即可。具体配置如下:thconfig -set FABRIC -area ED -highthreshold -value 0 -trigger above -action raslogthconfig -apply FABRIC -area ED -action_level cust -thresh_level custthconfig -show FABRIC -area ED D) switch配置1)、EnvironmentTemperature配置保持系统默认参数060度。Fan配置保持系统默认参数16003400RPM。Power Supply配置保持系统默认参数1 OK/0 FAULTY。2)、SFP收发光功率配置为监控SFP收光功率,请按下列图形的数字标识顺序进行Rx Power参数的配置,配置方法是在阀值配置(Threshold Configuration)中,将时间间隔(Time Base)选定为每分钟(Minute),其上限(High Boundary)为5000,下限(Low Boundary)为32;同时在报警配置(Alarm Configuration)中,勾选Below和Above所在行中的ERROR_LOG和SNMP_TRAP。具体配置如下:thconfig -set SFP -area RXP -highthreshold -value 5000 -trigger above -action raslogthconfig -set SFP -area RXP -lowthreshold -value 32 -trigger below -action raslogthconfig -apply SFP -area RXP -action_level cust -thresh_level custthconfig -show SFP -area RXP 为监控SFP发光功率,请按下图进行Tx Power参数的配置,配置方法是在阀值配置(Threshold Configuration)中,将时间间隔(Time Base)选定为每分钟(Minute),其上限(High Boundary)为5000,下限(Low Boundary)为126;同时在报警配置(Alarm Configuration)中,勾选Below和Above所在行中的ERROR_LOG和SNMP_TRAP。具体配置如下:thconfig -set SFP -area TXP -highthreshold -value 5000 -trigger above -action raslogthconfig -set SFP -area TXP -lowthreshold -value 126 -trigger below -action raslogthconfig -apply SFP -area TXP -action_level cust -thresh_level custthconfig -show SFP -area TXP3)、Security所有的安全配置保持系统默认参数。4)、Resource交换机逻辑卷空间配置保持系统默认参数85.5)、FRU交换机的可替换部件(如电源、wwn卡、风扇、板卡)保持系统默认absent告警。c) Switchdisable并确认PID format用configshow显示 PID,并确认与被替换交换机一致(应PID=1)Configshow all | grep pidformat确认fabric.ops.mode.pidFormat:1d) 确认BBcredit用configshow显示 BBcredit并确认与被替换交换机一致(默认为16)Configshow确认为fabric.ops.BBCredit:16e) Firmware版本一致E)Bottleneck 配置 为监控F_Port的延迟情况,防止系统中出现慢速设备,从而影响整个系统的运行,需要进行bottleneckmon参数的配置。bottleneckmon -enable -cthresh 0.80 -alert -lthresh 0.02 -time 100 -qtime 60 act (边缘交换机)bottleneckmon -enable -cthresh 0.80 -alert -lthresh 0.02 -time 100 -qtime 60 (核心交换机)bottleneckmon -statusF)Port Fencing 配置基于FW中对EPORT、FPort的阀值设置,对在指定时间内超过阀值的端口实施自动Disable操作,从而防止不稳定端口影响Fabric中的其他链路所带来的影响。一、Server 交换机F Port 建议值Invalid Word low 25 & high 40CRC low 5 & high 20C3TX_TO 5 State Change 7Link Reset 5 1、Invalid Word low 25 & high 40设置上限:portthconfig -set fop-port -area itw -timebase minute -h -va 40 -tr above -action raslog -buffer 0/portthconfig -set fop-port -area itw -h -tr below -action raslog设置下限(采用Port Class触发上限告警):portthconfig -set port -area itw -h -va 25 -tr above -action raslog -buffer 0/portthconfig -set port -area itw -h -tr below -action raslog应用设置:portthconfig -apply fop-port -area itw -ac cust -th custportthconfig -apply port -area itw -ac cust -th cust启用portfencing:portfencing -enable fop-port -area itw 检查设置:portthconfig -show fop-port -area itw portthconfig -show port -area itw检查port fencing设置:portfencing -show2、CRC low 5 & high 20设置上限:portthconfig -set fop-port -area crc -timebase minute -h -va 20 -tr above -action raslog -buffer 0/portthconfig -set fop-port -area crc -h -tr below -action raslog设置下限(采用port class触发上限告警):portthconfig -set port -area crc -h -va 5 -tr above -action raslog -buffer 0/portthconfig -set port -area crc -h -tr below -action raslog应用设置:portthconfig -apply fop-port -area crc -ac cust -th cust portthconfig -apply port -area crc -ac cust -th cust 启用portfencing:portfencing -enable fop-port -area crc 检查设置:portthconfig -show fop-port -area crc portthconfig -show port -area crc检查port fencing设置:portfencing -show3、C3TX_TO 5 设置上限:portthconfig -set fop-port -area c3tx_to -timebase minute -h -va 5 -tr above -action raslog -buffer 0/portthconfig -set fop-port -area c3tx_to -h -tr below -action raslog设置下限(采用port class触发上限告警):portthconfig -set port -area c3tx_to -h -va 0 -tr above -action raslog -buffer 0/portthconfig -set port -area c3tx_to -h -tr below -action raslog应用设置:portthconfig -apply fop-port -area c3tx_to -ac cust -th cust portthconfig -apply port -area c3tx_to -ac cust -th cust 启用portfencing:portfencing -enable fop-port -area c3tx_to 检查设置:portthconfig -show fop-port -area c3tx_to portthconfig -show port -area c3tx_to检查port fencing设置:portfencing -show4、State Change 7设置上限:portthconfig -set fop-port -area st -timebase minute -h -va 7 -tr above -action raslog -buffer 0/portthconfig -set fop-port -area st -h -tr below -action raslog设置下限(采用port class触发上限告警):portthconfig -set port -area st -h -va 0 -tr above -action raslog -buffer 0/portthconfig -set port -area st -h -tr below -action raslog应用设置:portthconfig -apply fop-port -area st -ac cust -th cust 启用portfencing:portfencing -enable fop-port -area st 检查设置:portthconfig -show fop-port -area stportthconfig -show port -area st检查port fencing设置:portfencing -show5、Link Reset 5 设置上限:portthconfig -set fop-port -area lr -timebase minute -h -va 5 -tr above -action raslog -buffer 0/portthconfig -set fop-port -area lr -h -tr below -action raslog设置下限(采用port class触发上限告警):portthconfig -set port -area lr -h -va 0 -tr above -action raslog -buffer 0/portthconfig -set port -area lr -h -tr below -action raslog应用设置:portthconfig -apply fop-port -area lr -ac cust -th cust portthconfig -apply port -area lr -ac cust -th cust检查设置:portthconfig -show fop-port -area lr启用portfencing:portfencing -enable fop-port -area lr 检查port fencing设置:portfencing -show二、所有交换机E Port 建议值Invalid Word low 25 & high 40CRC low 5 & high 20State Change 71、Invalid Word low 25 & high 40检查设置:portthconfig -show e-port -area itw portthconfig -show port -area itw 检查port fencing设置:portfencing -show2、CRC low 5 & high 20检查设置:portthconfig -show e-port -area crc portthconfig -show port -area crc检查port fencing设置:portfencing -show3、State Change 7设置上限:portthconfig -set e-port -area st -timebase minute -h -va 7 -tr above -action raslog -buffer 0/portthconfig -set e-port -area st -h -tr below -action raslog应用设置:portthconfig -apply e-port -area st
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- T/CACE 072-2023产品、场所和组织循环指数评价规范
- 人流术后护理课件
- T/BIKE 7.2-2020电动自行车锂离子蓄电池换电柜技术要求第2部分:锂离子电池组
- 2025年工业互联网平台边缘计算硬件架构边缘计算边缘计算技术标准研究报告
- 适老辅具的康复发展
- 2025年电动汽车电池热管理系统设计创新与案例分析报告
- 公路货运企业数字化转型与2025年效率提升的物流企业物流仓储管理
- 造血干细胞移植肠排护理
- 逆商心理健康教育
- 2025年未来交通系统中交通服务个性化定制的发展趋势研究报告
- GB/T 21618-2008危险品易燃固体燃烧速率试验方法
- 西安市非学历培训机构公示表
- QTZ1000塔机总体方案和平头式平衡臂结构设计及起升机构校核计算
- 盖梁穿心钢棒法受力分析计算书
- T∕CAME 27-2021 医院物流传输系统设计与施工规范
- YY∕T 1849-2022 重组胶原蛋白
- 三平寺签诗解全75首上
- (高清版)《预应力筋用锚具、夹具和连接器应用技术规程》JGJ85-2010
- 后张法预应力空心板梁施工方案
- 师德师风年度考核表
- 健康险产说会课件
评论
0/150
提交评论