




已阅读5页,还剩39页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Foroffice use only T1 T2 T3 T4 Foroffice use only F1 F2 F3 F4 TeamControlNumber 54164 ProblemChosen A 2016 MCM/ICM SummarySheet (Your teams summaryshouldbe included asthe firstpageof your electronicsubmission.) Type a summary ofyour results on this page. Donot include the name ofyour school, advisor, or team members on this page. Abstract We present a user-friendly strategy for keeping the water in a bathtub as close as possible to a certain preferred temperature. This strategy consists in two main constituents: adjusting the hot water flow from the faucet to keep the bathtub temperature suitably high, and using hand motions to distribute the heat evenly throughoutthebath water. Asfordeterminingthenecessarywaterflow,we first createa modelthat determines thetemperatureofthebath waterat any point in time.We posit that the temperatureof thewater in thebath isdependenton thecoolingdueto theambient temperature ofthe room,which obeys the proportionalitygiven by Newtons Law ofCooling;and the heating dueto theaddedhot water fromthefaucet. Ourmodelcombines the temperaturechanges over timefromthese twoentities intooneconsummate differentialequation. We determine the experimental constant of proportionalityfor Newtons Law ofCooling byproposing that thisconstant itselfis dependenton acombinationof volumeofthe water and surface area exposed to theair.Taking experimental datafromvaried sources, includingan experiment weconductedand documentedoverthetimeframeof theMCM competition,wewereable to extrapolate valuesforthe constant attributable to any bathtub given itsvolumeand surfacearea exposed toair. Wethen run a computersimulationto modelthetemperaturechangesover timein a standardbathtubwith ourdifferential equation,determininghowmuchhotwater needsto flowin to keep thetotal devianceover timeofthetemperatureofthebath froma desired temperatureat aminimum.We foundtheoptimal flowrate fora standardbathtub at standardconditionsto be 1.81gallons/minute, or about 11%ofthe maximumflow rate. Ourmodelwasable to predict optimal flowrates formanydifferent combinations of volume,surface area, tub material,and additives.We foundthat moreeffective insulatingmaterialsled toloweroptimal flowrates (less hotwater needed),as didthe additionofadditives.Volumeand surfacearea, surprisingly,showedno cleartrend. Asforkeepingthetemperatureroughlyeven in thebathtub, wesuggest that theuser swirlhis handscounter-clockwisewith respectto thefaucet as shownin Figure1.This is a simple yet effectivewayto distributetheheat acceptablyevenly throughout thetub water. Asalternatives forthose who donotwish to make theirbath intoan exercisesession, weinvented an originalproduct (HomeJacuzzi)that is low-cost and aidsin heating the waterevenly. The Math Behind the Bath: A ”Cool” Investigation on Cooling Team #54164 February 2016 Team#54164Page1of 42 Page 1 1Abstract We present a user-friendly strategy for keeping the water in a bathtub as close as possible to a certain preferred temperature. This strategy consists in two main constituents: adjusting the hot water flow from the faucet to keep the bathtub temperature suitably high, and using hand motions to distribute the heat evenly throughout the bath water. As for determining the necessary water flow, we first create a model that determines the tem- perature of the bath water at any point in time. We posit that the temperature of the water in the bath is dependent on the cooling due to the ambient temperature of the room, which obeys the proportionality given by Newtons Law of Cooling; and the heating due to the added hot water from the faucet. Our model combines the temperature changes over time from these two entities into one consummate differential equation. We determine the experimental constant of proportionality for Newtons Law of Cooling by proposing that this constant itself isdependent on a combination of volumeof the water and surface area exposed to the air. Taking experimental data from varied sources, including an experiment we conducted and documented over the time frame of the MCM competition, we were able to extrapolate values for the constant attributable to any bathtub given its volume and surface area exposedtoair. We then run a computer simulation to model the temperature changes over time in a standard bathtub with our differential equation, determining how much hot water needs to flow in to keep the total deviance over time of the temperature of the bath from a desired temperature at a minimum. We found the optimal flow rate for a standard bathtub at standard conditions to be 1.81 gallons/minute, or about 11% of the maximum flow rate. Our model was able to predict optimal flow rates for many different combinations of volume, surface area, tub material, and additives. We found that more effective insulating materials led to lower optimal flow rates (less hot water needed), as did the addition of additives. Volume and surface area, surprisingly, showed no clear trend. As for keeping the temperature roughly even in the bathtub, we suggest that the user swirl his hands counter-clockwise with respect to the faucet as shown in Figure 1. This is a simple yet effective way to distribute the heat acceptably evenly throughout the tub water. Asalternativesforthose whodo notwish tomaketheirbathintoanexercise session,weinvented an original product (Home Jacuzzi) that is low-cost and aids in heating the water evenly. 1.1Non-Technical Explanation Why isitso difficult to keep the temperature of the water even throughout when taking a bath? In a standard single-faucet bathtub, hot water comes out of the faucet on only one side of the bath, leaving the other side of the bath colder until enough time passes for the temperature to even out. When left running, this might take more time than a user wants to wait for. To further complicate things, hot water is also slightly less dense than cold water, and will thus be more concentrated on the surface of the bathtub than the bottom of the tub. To make the temperature consistent, the easiest solution is to cup your hands and circulate the hot water from the side with the faucet to the other side of the tub, and also circulate the hot water from the water surface to the bottom of the top. Another option, however, for those of us who dont want to spend the duration of our bath flailing our arms, is to use our invention, ”Home Jacuzzi.” Our invention spans the length and Team#54164Page2of 42 Page 2 width of the bathtub, and attaches onto the faucet. The hot water from the faucet is then funneled through the device towards the bottom of the tub, creating a Jacuzzi-like effect. The hot water then rises to the surface, mixing with the water aboveitand creating an evenly distributed, uniform temperature throughout the tub. Now that we can keep the temperature consistent throughout the tub, were still left to figure out how high we should turn our faucet to keep the water from going cold. Ofcourse, turningittoohighisawasteofwaterand, on topofthat, canincrease the temperature to uncomfortably high levels. Too low, and we get to wade around in lukewarm to cold waters that make us not want to take a bath at all. So we want to find the optimal flow rate on our faucet that gets our temperature to where we wantitto be. Not all bathtubs were created equal. The optimal flow rate isnt a set rate for all bathtubs. For the standard 60”x30”x14” bathtub, we suggest turning the faucet up to about a ninth of its max. To conserve even more hot water, you even have the option of purchasing products like the”WaterBlanket”(”WaterBlanket”)tokeepthetemperatureofthebathwarmer. Interestingly enough, even bubble bath can keep your bath water hotter for longer. And no, its not ”just for kids.” Contents 1Abstract1 1.1Non-Technical Explanation. 1 2Introduction3 2.1Background.3 2.2Restatement of Problem.3 3The Strategy4 3.1Distribution: A Simple Solution.4 3.2Global Assumptions.4 4Simulating Heat Transfer5 4.1Local Assumptions.5 4.1.1Variable Nomenclature.6 4.2Creation of the Model. 6 4.2.1Cooling.6 4.2.2Experimental Data.7 4.2.3Heating.12 4.3Simulation Design.13 4.3.1Selecting Optimal Flow Rate.14 4.3.2Validation of Model.16 5Sensitivity Analysis: Varying Bathtub Characteristics16 5.1Varying Surface Area Under Constant Volume. 16 5.2Varying Volume Under Constant Surface Area. 24 5.3Observations.32 Team#54164Page3of 42 Page 2 5.4Material of Bathtub. 34 5.5Additives (bubble bath). 35 6Conclusion36 6.1Results.36 6.2Strengths of Model.36 6.3Limitations of Model.36 6.4Future Work/Discussion.37 6.5Home Jacuzzi.37 Appendices39 AExperimental Design for Real-World Bathtub Data39 BSimulation Code39 2Introduction 2.1Background Baths, the best way we had to cleanse ourselvesuntil we became teens and discovered showers, at which point baths became ”uncool.” Yet, whenever we want to slow life down and relax a little, we can rest assured that the bath will always be there to ease our nerves. The health benefits of taking a bath are plentiful (”5 Reasons You Need To Take A Bath”), but no one wants to hop into a steaming hot tub only to find him or herself in cold or lukewarm water a half-hour later. Then, how can one keep a bath warm long enough to last a preferred duration? Most people own simple bathtubs, unequipped with secondary heating systems or circulating jets. Several factors can affect the temperature change of bath water, including: the surface area of water exposed to air the volume of water that is being cooled the surrounding air temperature the rate of hot water flow into the bathtub the material the bathtub is made out of (and how wellit is able to provide insulation) whether any additives are introduced to the water, such as a bubble bath solution 2.2Restatement of Problem A person has settled into a bathtub for a long, relaxing bath, only to find that after some time, the water has become noticeably cooler. In an attempt to salvage his satisfaction, he elects to turn on the faucet and let in some hot water to bring the temperature back up. Excess tub water leaves the tub through an overflow drain. Of course, he runs into a set of issues: Team#54164Page4of 42 Page 4 The water in the tub is of inconsistent temperature, being hotter in some areas and cooler in others. Turning the hot water flow too high is a waste of water (and money). 3The Strategy Our ”strategy” presented to the person in the tub will be a combination of the solutions to queries 1 and 2the person will have to take action to evenly distribute the heat in the bathtub water, and the person will have to set the hot water flow in at a certain flow rate to keep the bathtub water hot. 3.1Distribution: A Simple Solution We begin by addressing query number ”1”. In a standard single-faucet bathtub, water flows from above on one side of the bathtub. Since hot water rises, more heat will be concentrated at the top of the bathtub. Because the faucet is only on one side of the tub, more heat will be concentrated on the side of the tub closest to the faucet. Therefore, we advise the person in the tub to cup his hands and make circles in the water as illustrated below: Figure1: Proposedstrategyforequalizingthetemperatureofthewaterinanysingle-faucetbathtub. 3.2Global Assumptions The standard bathtub is open and exposed to the airon the top surface, and built with acrylic material that is heavily insulated (”Bathtub Sizes”). Heat loss through heavily insulated surfaces is negligible. Heat loss through surfaces of poor insulation (thin glass, thin fiberglass) behaves as if that surface was directly exposed to air. The person in the bathtub follows the suggestion in Figure 1, allowing us to assume that water temperature is consistent throughout the tub at any point in time. Team#54164Page5of 42 Page 5 The temperature sensitivity of the human body is such that we begin noticing appreciable differences in temperature at1.4C from the original temperature (Davies et al. 171) The target temperature for the bath water is human body temperature, which is approxi- mately 37C. Since the person inside the tub is at thermal equilibrium with the water in the tub, we can treat the persons body as an extension of the bathtub water. Room temperature remains constant throughout the duration of the bath, at 21C, the ac- cepted value for ambient room temperature. The faucet from which the hot water flows has a maximum flow rate of 16 gallons/min (”Bathtub Faucets”), and the person is able to toggle the faucets flow rate to any rate between 0 gallons/min and 16 gallons/min. The hottest water we can release from the faucet has a temperature of 48C to prevent injury from scalding (A.O. Smith Corporation 1). This will be the assumed temperature of the additional water from the faucet. All bathtubs used in this paper for simulation and data are filled to the brim with the com- bination of water and person. 4Simulating Heat Transfer To address our second query, we consider a thermodynamic system of five constituents: the water in the tub, the water entering and leaving the tub, the walls of the tub, the human in the tub, and the air outside the tub. Heat transfer with the human and the walls is negligible as justified in our global assumptions. Thus, we need only consider the cooling of the tub water due to the air outside, and the heating of the tub water due to the incoming hot water. 4.1Local Assumptions The industry standard bathtub in America is 60”30”14”, which results in a volume of 603014=25,200in3and surface area exposed tothe airof 6030=1,800in2(”Bathtub Sizes”). Since the majority of bathtubs in America are insulated, we assume that the bathtub that we are simulating is well insulated on all sides except for the top. Therefore, heat can only escape from the bathtub from the top surface. Water cooling obeys Newtons Law of Cooling closely enough to approximate a model for temperature over time. The ambient temperature is 21C. The temperature of the hot water from the faucet is 48C. Page 6 Team#54164Page6of 42 4.1.1Variable Nomenclature Below are the variables used throughout our model: k = cooling constant T =temperatureofthewaterminusambientroom temperature T0= initial temperature of the bathtub t = time in minutes SAE=surface area exposed to air in square meters V = volume in liters Q=change in heat energy, in joules m = mass of the water in the tub, in grams Cp=specificheatofthewater,inJoulesper gram-degree C 4.2Creation of the Model Since the temperature of the water is constantly being altered bythe cooling due to the surrounding air temperature and the heating due to the incoming water flow, we created an equation to model the changes in temperature, based on Newtons Law of Cooling and the specific heat capacity formula. 4.2.1Cooling The first part of the model accounts for the cooling of the water due to the temperature of the environment. We chose to model this cooling with Newtons Law of Cooling, which states that the difference in temperature is directly proportional to the negative of the current temperature, or dT dt =kT(1) where T is the temperature, and k is the cooling constant that is derived from experimentation. To derive the form we want our regression equation for our experimental data to be in, we solve our differential equation by integration with separation of variables: 1 T dT =kdt(2) 1dT = T kdt(3) ln(T) =kt + C(4) where C is a constant. Solving for T, T = ekt+C= Cekt(5) Team#54164Page7of 42 Page 7 To solve for this constant of integration, C, we substitute in the initial temperature T0of the wate
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年自考专业(建筑工程)考试黑钻押题(夺分金卷)附答案详解
- 绍兴市烟草公司2025秋招笔试综合模拟题库及答案行测公基烟草知识
- 2024-2025学年度扬州中瑞酒店职业学院单招《英语》试题预测试卷含答案详解(考试直接用)
- 中国邮政2025贵港市秋招大堂经理岗位高频笔试题库含答案
- 幼教招聘考试题库及答案
- 2025年辽宁省调兵山市中考数学真题【夺分金卷】附答案详解
- 2025年人教版7年级数学上册期末试题附参考答案详解【满分必刷】
- 永川数学初一考试题及答案
- 影视安全考试题库及答案
- 2025年度水电安装消防系统安装与节能改造服务合同
- 养老护理员全套培训课件
- JJF 2250-2025 数字化交流电能表型式评价大纲
- 河北计算机单招数学试卷
- DB11T 751-2025 住宅物业服务标准
- 2025至2030全球及中国两轮组合仪表行业产业运行态势及投资规划深度研究报告
- 2024公路运营领域重大事故隐患判定标准解读学习课件
- 耕地保护培训课件
- 文化设计符号解析-洞察及研究
- MES追溯管理制度
- 脊柱侧凸矫形术麻醉管理
- 中职语文拓展模块上册教学计划
评论
0/150
提交评论