版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、SY5000/CMU-BATS Auto Switch controllerUser ManualV1.1CONTENTS1.FEATURES2.2.CONTROLLER EXTERIOR FIGURE3.3.PARAMETER RANGE AND DEFINE3.4.OPERATION4.4-1KEY FUNCTION4-2SETTING PARAMETER4-3MANUAL OPERATION4-4AUTOMATIC OPERATION5.FACTORY DEFAULTSPARAMETER5.6.INSTALLATION5.7.TYPICAL WIRING DIAGRAM6.8.SALE
2、SERVICE7.1、FEATURESSY5000/CMU-B double power switching controller is based on micro processor as the core of the new generation of intelligent controller. Real-time monitoring the mains and backup power these two road voltage. Be able to appear lost electricity,over-voltage,undervoltage,phase lack,e
3、tc,abnormal conditions make accurate judgement.And by manual or automatic mode switch ATS switch movement,which realizes automatic and unattended function,etc.n The ATS controller be used LCD digital design,Parameters is Chinese and English display.n The product can accurately acquisition and displa
4、y the main power/second power two way three-phase voltages.n The product parameter settings by password protection.n The ATS controller power supply mode can set mains power priority,backup power priority or no priority.n When a switch off failure,if another voltage to normal,the ATS controller will
5、 automatically switch to the way.n The ATS controller can install voltage alarm value and delay switch time.n The product have generator start function.n The ATS controller can chose single-phase/three-phase display,monitoring.n The product have two way N line separation design.n The ATS controller
6、can autosave fault record,inquires is more conveniently.n The ATS controller can be used DC power(935Vsupply or A/N phase voltage.2、CONTROLLER EXTERIOR FIGURE SY5000CMU-B3、SPECIFICATIONS3.1Power Supply :DC12V (range from 9to 35V ;AC220V (197-270V L-N3.2Generator input Voltage Range :0to220V AC ,3pha
7、se 4wire 3.3Power dissipation :<3VA at rated voltage34Operating Temperature Range :-20to +60Humidity Range :20to 754、OPERATION4-1、controller display properly state as follows: 4-2、SETTINGPARAMETERPress the key 5seconds,enter "password"interface,Input 4digit password,User can only by mon
8、itoring software to modify this password,Ordinary users password:1234Password input method:In the input password interface,Press the key,value add 1,Whenvalues increase to password bits,Pressthe key confirmation,Then interface jump to the second password bits,Repeat the above operation,input the rem
9、aining three password bits,and then enter into "menu",if a password mistake will not have access to menu system. In the menu system,Press thekey into the next page ,Press the key to modification parameter.When the control screen upward modification parameter.Then press key to increase the
10、value,Increased to maximum continuous buttons,then the system automatically return to low cycle.If press key,then exit set condition returns to the system default state.4.3Manual switching operationWhen the user manual debugging ATS switch,Through panel of buttons can be manually switched,each time
11、press the button will switch to correspond to the end.Specific steps: Press thekey will be the key controller is set to "manual"state,If switch to the main source control please press the key,If switch to standby power control please press the key.Note:in key-press,controller has 6seconds
12、countdown switch time,press other switch button is invalid,and if the countdown unfinished.0000 User can also through input password,the system parameters interface to "manual","automatic"Settings4.4Automatic switching set operationwhen the movement User Settings ATS switch autom
13、atically,need through controller internal priority to set up"the mains priority"-"standby power priority"-"no priority".Specific steps:First press thekey to enter the password Settings,enter the correctpassword and press thekey to scroll to"power priority model&quo
14、t;interface,After presskey choose"mains first"or"standby power first"or"no priority"of three modes.If exit system press thekey.5、FACTORY DEFAULTS PARAMETERTepy Factory Reset Set rangemains under voltage200V180V-220Vmains over voltage240V230V-250V200V180V-220VBackup powe
15、r undervoltage240V230V-250VBackup power overvoltageMains time delay normal5S0-60S5S0-60SMains time delayabnormalBackup time delay5S0-60Snormal5S0-60SBackup time delayabnormalGenerator start time0S0-90Sdelay5S0-90SGenerator stop timedelayPrior supply mode mains power priority:mains power priority:bac
16、kup power priority:not priorityStatus Auto:manual:autoSupply display mode Display three phase DisplayDisplay switch time Recover factory set 6S Not recover single-phase/three phase 1-9S :recover :not recover 6、 controller mounted controller mounted: With the product distribution two installation ear
17、s fixed. Overall dimension:140x120x56mm (W X H X D Cut-out for fix dimension: 128x112mm (W X H 7、connection diagram 7-1、 According to SY5000/CMU-B controller of each port after shell that correct connection wiring. SY5000/CMU-Bback diagram 6 7-2、 SY5000/CMU-B controller wiring terminal explain Termi
18、nal A1、B1、C1、N1 Wiring explain Remark Connect mains AC 198V-242V A,B,C,N M1、M2 Connect relay output 16A 250VAC CLOSE 1# L1、L2 Connect AC battle AC 198V-242V line VIN、GND connect DC Controller power plus-minus supply DC 9V-36V M3、M4 Connect relay output 16A 250VAC CLOSE 2# A2、B2、C2、N2 Connect backup power AC 198V-242V A,B,C,N M5、M6 Connect generator 10A 250VAC relay output According to SY5000/CMU-B controller of each port after shell that cor
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- Bootstrap响应式网站开发任务式教程课件 任务6 使用Bootstrap表单
- 2025年儿童健康监测协议
- 机构研究报告-智慧工地技术的现状及发展趋势-培训课件
- 2025年乡村民宿个性化服务分析行业报告
- 《数字化金融监管下金融科技应用的风险与合规策略分析》教学研究课题报告
- 高中生运用地理信息模拟城市内涝应急消防设施布局方案课题报告教学研究课题报告
- 2026年雅安市消防救援局面向社会招录消防文员的备考题库及完整答案详解
- 2026年南京城市职业学院单招职业技能笔试备考试题及答案解析
- 2026年临颍县事业单位人才引进备考题库及答案详解参考
- 机器学习算法在初中化学实验数据分析教学中的应用课题报告教学研究课题报告
- 门店分期转让合同协议
- 销售部年终总结及明年工作计划
- 瑜伽馆年度店长工作总结
- 工作计划执行跟踪表格:工作计划执行情况统计表
- 高效空调制冷机房的关键技术现状与展望
- 医院药学信息服务的方式(医院药学)
- 《小讲课糖尿病》课件
- 《Y移动互联网公司校园招聘问题与优化策略》9200字(论文)
- 数字逻辑与数字系统知到智慧树章节测试课后答案2024年秋武汉科技大学
- 城市道路路基土石方施工合同
- 南京工业大学甲醇制氢工艺设计(反应器)
评论
0/150
提交评论