1、 3/3专业英语原文和翻译 Basic Control Actions and Industrial Automatic Control An automatic controller compares the actual value of the plant output with the desired value, determines the deviation, and produces a control signal which will reduce the deviation to zero or to a small value.The manner in which t
2、he automatic conroller produces the control signal is called the control action. Classifications of industrial automatic controllers Induetrial automatic controllers may be classified according to their control action as: two-position or on-off controllers; proportional controllers; integral control
3、lers; proportional-plus-integral controllers; proportional-plus-derivative controllers; proportional-plus-derivative-plus-integral controllers. Most industrial automatic controllers use eletricity or pressurized fluid such as oil or air as power sources. Automatic controllers may also be classified
4、according to the kind of power employed in the operation, such as pneumatic controllers, hydraulic controllers, or electronic controllers.What kind of controller to use must be decided by the nature of the plant and the operating conditions,including such considerations as safety, availability, reli
5、ability, accuracy, weight, and size? Elements of industrial automatic controllers An automatic controller must detect the actuating error signal, which is usually at a very low power level, and amplify it to a sufficiently high level. Thus, an amplifier is necessary. The output of an automatic contr
6、oller is fed to a power device, such as a pneumatic motor or valve, a hydraulic motor, or an electric motor. The controller usually consists of an error detector and amplifier. The measuring element is a device that converts the output variable into another suitable variable, such as a displacement,
7、 pressure, or electric signal, which can be used for comparing the output to the reference input signal. This element is in the feedback path of the closed-loop system. The set point of the controller must be converted to a reference input of the same units as the feedback signal from the measuring
8、element. The amplifier amplifies the power of the actuating error signal, which in turn operates the actuator. The actuator is an element which alters the input to the plant according to the control signal so that the feedback signal may be brought into correspondence with the reference input signal
9、. Self-operated controllers In most industrial automatic controllers, separate units are used for the measuring element and for the actuator. In a very simple one, however, such as a self-operated controller, these elements are assembled in one unit. Self-operated controllers utilize power developed
10、 by the measuring element and are very simple and inexpensive. The set point is determined by the adjustment of the spring force. The controlled pressure is measured by the diaphragm. The actuating error signal is the net force acting on the diaphragm. Its position determines the valve opening. The
11、operation of self-operated controller is as follows: Suppose that the output pressure is lower than the reference pressure, as determined by the set point. Then the downward spring force is greater than the upward pressure force, resulting in a downward movement of the diaphragm. This increases the
12、flow rate and raises the output pressure. When the upward pressure force equals the downward spring force, the valve plug stays stationary and the flow rate is constant. Comversely, if the output pressure is higher than the reference pressure, the valve opening becomes small and reduces the flow rat
13、e through the valve opening. Such a self-operated controller is widely used for water and gas pressure control. In such a controller, the flow rate through the valve opening is approximately proportional to the actuating error signal. Control actions The following six basic control actions are very
14、common among industrial automatic controllers: two-position or on-off, proportional, integral, proportional-plus-integral,proportional-plus-derivative,and proportional-plus-derivative-plus-integral control action. Note that an understanding of the basic charateristics of the various actions is neces
15、sary in order for the control engineer to select the one best suited to his particular application. 翻译: 自动控制器把对象的实际输出与期望值进行比较,确定偏差,并产生一个使误差为零或微小值的控制信号。自动控制器产生控制信号的方式叫做控制作用。 工业自动控制器的分类根据控制作用,工业自动控制器可分为: 双位或继电器控制器; 比例控制器; 积分控制器; 比例-积分控制器; 比例-微分控制器; 比例-微分-积分控制器。 多数工业自动控制器采用电或诸如油或空气一类的压缩流体作为能源。自动控制器还可以根
16、据工作时使用的能源分类,如气动控制器、液压控制器或者电动控制器。控制器的选用取决于对象的性质和工作条件,包括安全性、实用性、可靠性、精度、重量和体积等方面的考虑。 工作自动控制器的元件自动控制器必须检测出功率通常很小的误差信号,并将其放大到足够大的强度。因此,放大器是必不可少的。自动控制器的输出被传送到动力设备,如气动发动机或气动阀、液压电动机或电动机。 控制器一般由误差检测器和放大器组成。测量元件是将输出变量转换为其他合适的形式的变量,如移位、压力或电信号等这些都可以做输出量,并与参考输入信号进行比较。该元件一般在闭环系统的反馈回路中。控制器的设定值必须转换为与测量元件的反馈信号单位相同的参考输入信号。放大器将误差信号进行放大,用以控制执行机构。执行机构是根据控制信号的大小改变对象输入的设备,这样就可以使反馈信号与参考输入信号一致。 自操作控制器在多数工业自动控制器中,测量元件和执行机构都是独立的装置。只是在像自操作控制器这样简单的控制器中,才将他们组合称一个整体。自操作控制器利用测量元件产生能源,结构简单,价格廉价。给定值通过调节弹簧的弹力来确定,被控力由膜片测量。误差信号是作用在膜片上的净力,膜片的位置决定了阀的开度。 自操作控制器的工作原理:假定输出压力低于由给定值确定的参考压力,向下的弹力
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 网络化时代出版传播方式变革
- 护理敏感指标:患者安全与风险管理
- 护理体态礼仪与专业形象
- 2026年市场监管部门管出公平反垄断画好“跑道的边界”
- 疼痛护理中的法律问题
- 2026年云边端协同智能制造技术架构设计
- 2025年前台服务技巧专项卷
- 电力管道施工组织设计方案1
- 护理课件制作排版技巧
- 统编版四年级下册语文古诗词三首《宿新市徐公店》教案简案
- 2026教育培训产业市场供需分析与未来发展预测研究报告
- 2026春统编版六年级道德与法治下册(全册)课时练习及答案(附目录)
- 2026年安庆医药高等专科学校单招综合素质考试题库及答案1套
- 2025天津市西青经开区投资促进有限公司面向全国公开招聘招商管理人员4人备考笔试试题及答案解析
- 鼻饲喂养的技巧与技巧
- 2026年辽宁医药职业学院单招职业技能测试题库及完整答案详解1套
- 校园安全从我做起
- DGTJ08-10-2022 城镇天然气管道工程技术标准
- 安全事故发生的4个原因
- 2024年9月21日九江市五类人员面试真题及答案解析
- 基于多模型融合的飞机液压防滑刹车系统故障诊断技术深度剖析
评论
0/150
提交评论