BasicmethodoftestCONTENTSPAGETypeandperiodofroutineinspectionofrelayprotection0102BasictestmethodforrelayprotectionTypeandperiodofroutineinspectionofrelayprotection01TypeandperiodofroutineinspectionofrelayprotectionAccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDeviceInspectionofconventionalsubstationrelayprotectionandpowergridsafetyautomaticdevicesincludesTheroutinemaintenanceandinspectiontypesaredividedintothreecategories:a)Acceptanceandinspectionofthenewlyinstalledprotectiondevicesb)Regularinspectionofprotectiondevicesinoperation(referredtoasregularinspection);c)Supplementaryinspectionoftheprotectiondeviceinoperation(simplysupplementaryinspection)TypeandperiodofroutineinspectionofrelayprotectionAccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDeviceAcceptanceinspectionofnewlyinstalledprotectiondevicesAcceptanceinspectionofnewlyinstalledprotectiondevicesshallbeconductedasfollows:a)Whenthenewlyinstalledprimaryequipmentisputintooperation;b)Whenputtinginnewlyinstalledprotectivedevicesonexistingprimaryequipment..AccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDevicePeriodicinspectionoftheprotectiondevicesinoperationRegularinspectionisdividedintothreetypes:a)Allinspectionsb)Partialinspectionc)Conductthecircuitbreakertripandclosingtestwiththeprotectiondevice.TypeandperiodofroutineinspectionofrelayprotectionAccordingtoDLT995-2016InspectionSpecificationforRelayProtectionandGridSafetyTheSupplementarytestsweredividedintofivecategoriesa)Inspectionaftermakinglargechangestotheprotectiondeviceinoperation(includingtheprotectiondevicesoftwareversionupgrade)ortheadditionofnewcircuitsb)Inspectionafteroverhaulorreplacementofequipmentoncec)Testaftertheabnormalityisfoundduringtheoperationd)Post-accidentinspection:e)Theprotectiondevicethathasbeenputintooperationhasbeenpoweredoffforoneyearormore,andtheinspectionwhenitisputintooperationagainTypeandperiodofroutineinspectionofrelayprotectionAccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDeviceContentandcycleofperiodicinspectionRegularinspectionshallbecarriedoutinaccordancewiththecyclespecifiedinthisstandard,theprojectandthecontentsofthestandardizedoperationinstructionsapprovedbythecompetentauthoritiesatalllevels.Theformulationofregularinspectioncycleplanshalltakeintoaccountthevoltagelevelandworkingconditionsoftheequipmentunderitsjurisdiction,andshallbecarriedoutaccordingtothecycleandprojectsrequiredbythestandard.Generallyspeaking,intheeventofapoweroutageandmaintenanceoftheequipment,regularinspectionsshouldbecoordinatedasmuchaspossible.TypeandperiodofroutineinspectionofrelayprotectionAccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDeviceAllinspectionandpartialinspectioncycletableofprotectiondevicesof220kVvoltagelevelandabovenumberdevicetypeAllinspectioncycle(year)Definingrangedescription1Microcomputer-typeprotectiondevice6ItincludesAC,DCandoperationcircuitoutsidetheintroducedterminal,relatedauxiliaryrelay,auxiliarycontactofoperationmechanism,automaticswitchofDCcontrolcircuit,etcnumberdevicetypePartialinspectioncycle(year)Definingrangedescription1Microcomputer-typeprotectiondevice2~4ItincludesAC,DCandoperationcircuitoutsidetheintroducedterminal,relatedauxiliaryrelay,auxiliarycontactofoperationmechanism,automaticswitchofDCcontrolcircuit,etcTypeandperiodofroutineinspectionofrelayprotectionAccordingtotheDL/T995-2016InspectionCodeforRelayProtectionandPowerGridSafetyAutomationDeviceContentsoftheSupplementaryTest1.Inspectionduetothemaintenanceorreplacementoftheprimaryequipment(circuitbreaker,currentandvoltagetransformer,etc.)shallbeinspectedbytherelayprotectiondepartmentoftheoperationandmaintenanceunit,determinetheinspectionitemsofprimaryequipmentaccordingtothenatureofprimaryequipmentmaintenance(replacement).2.Afterthelargechangesoftheprotectiondeviceinoperationorthesecondarycircuitchangeofthedevice,itshallbeinspectedbytherelayprotectiondepartmentoftheoperationandmaintenanceunit,andtheinspectionitemsshallbedeterminedaccordingtotheirworkingnature.3.Iftheprotectiondeviceisabnormalortheincorrectactionofthedeviceandthereasonisunknown,therelayprotectiondepartmentoftheoperationandmaintenanceunitshallformulatethespecificinspectionitemsandinspectionsequenceaccordingtotheaccidentsituation,andcarryoutthepost-accidentinspectionassoonaspossible.Aftertheinspectionwork,thereportshallbeputforwardintimeandsubmittedforreferenceaccordingtotheauthorityofequipmentdispatchingforfuturereference.Basictestmethodforrelayprotection02BasictestmethodforrelayprotectionAccordingtoGB/T7261BasicTestMethodforRelayProtectionandGridSafety-2016ThestandardspecifiesthebasictestmethodsforrelayprotectionandsafetyautomaticdevicesDefindefinedbasicperformancetestsinclude1.Relaycontactbasicparameterstest2.Testofcoilbasicparameters3.Testofthebasicparametersoftheconverter4.Withorwithoutrelayfunctiontest5.Accuracytestofthecharacteristicsofmeasuringrelayanddevice6.Timecharacteristictest7.Switchquantityinputandoutputtest8.MeasurementandcontrolperformancetestAtpresent,thecommoninspectionitemsofsubstationmicrocomputerprotectiondeviceinspectionare3,5,6and7,Specifictestitems,methodsandrequirementsvarydependingonthecompositionprinciple.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples1.appearanceinspection1)Checkwhethertheinsideandoutsideoftheprotectiondevicearecleanwithoutdustaccumulation;2)Cleanthedustontheterminalrowofthecircuitboardandthescreencabinet;3)Checkwhetherthesmallswitches,trackwheel

andbuttonsofthedevicearegood;4)Whetherthedisplayscreenisclearandwhetherthetextisclear;5)Checktheprintedcircuitboardsofeachplug-infordamageordeformation,andwhethertheconnectioniswellconnected;6)Checkwhetherthecomponentsoneachplugarewellweldedandwhetherthechipispluggedin;7)Checkwhethertheconverterandrelayoneachplug-inarefixedorloose;8)Checkwhethertheterminalrowscrewofthedeviceistightened,andwhethertherearpanelwiringiswellconnected;BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples2.Workpowersupplyinspection1)Checkat80%ratedpower:protectiondeviceshallworkstably.2)Powerself-starttest:closethepowerswitchontheDCpowerplug-in,andslowlyadjustthetestDCpowersupplyfromzeroto80%ratedpowervalue.Atthistime,theoperatinglightoftheprotectiondeviceshouldbeonandthereisnoabnormality.3)DCpowersupplypull-intest:pullandclosetheDCworkingpowersupplythreetimesat80%oftheratedvoltageoftheDCpowersupply,theinverterwillstartreliably,andtheprotectiondevicewillnotmalfunctionorsendsignalsbymistake.4)Thereisnoabnormalityinthepoweroffrecoveryprocessoftheprotectiondevice,andtheworkisstableandnormalafterpoweron.5)Whenthepowerisdroppedontheprotectiondevice,theprotectiondeviceshouldnotsendabnormaldata,andtherelayshouldnotbeoperatedbymistake.6)Duringregularinspection,alsocheckwhethertheinverterpowersupplyisclosetotheminimumfault-freeworkingtimespecifiedinDL/527-2013,andifclose,itshouldbereplacedintime.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples3.Analog-to-digitalconversionsysteminspection1)Checkthezerodrift.Duringtheinspectionofthisproject,itisrequiredthattheprotectiondevicedoesnotinputACcurrentandvoltage,andthezerodriftvalueoftheobservationdevicewithinaperiodoftimemeetstherequirementsofthesettechnicalconditions.2)Checktheamplitudeandphaseaccuracyofeachcurrentandvoltageinput.Duringtheacceptanceinspectionofthenewlyinstalledprotectiondevice,inputthecurrentandvoltageofdifferentamplitudesandphasesaccordingtothetestmethodspecifiedinthetechnicalspecificationofthedevice,andobservethatthesamplingvalueofthedevicemeetstherequirementsofthetechnicalconditionsofthedevice.Inallinspections,onlythecurrentandvoltageofdifferentamplitudescanbeinputrespectively;insomeinspections,onlyconstantcurrentandvoltagecanbeinputseparately.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples4.SettinginspectionoffixedvalueThesettinginspectionofthesettingvaluereferstothetestaftersettingtheoperatingvalueandoperatingtimeofeachrelevantelementoftheprotectiondeviceaccordingtothefixedvaluenotice.Thespecifictestitems,methodsandrequirementsvarydependingonthecompositionprinciple.Generally,thepositivelogicisusedtotestthecorrectactionofthefixedvaluecharacteristic,andtheinverselogicpartdoesnotmeettherequirementstotestwhetheritiscorrectornot,soastoensureitscorrectness.E.g:Thefixedvalueinspectionofacertainsectionofdistanceprotectionshouldverifyboth0.95timesreliableactionand1.05timesreliablenon-action.Directionalcurrentprotectioninspection,notonlytoverifythereliableactionwithintheforwarddirectionactionrange,butalsotoverifythereversedirectionnon-actionrangeCircumstancesanddrawconclusionsofactionboundaryanalysis.Fortheslipblockingconditioninlowfrequencyloadshedding,itisnecessarytoverifyboththereliableoperatingvalueofdf/dtandthereliableblockingvalue.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples5.Settinginspectionoffixedvalue1)Eachsetofprotectionshouldbeindividuallycheckedforsetting,andtheACandDCpowersupplyandtimemeasurementwiringinthetestwiringcircuitshouldbedirectlyconnectedtotheterminalblockoftheprotectionpanelundertest.TherelativepolarityrelationshipoftheACvoltageandcurrenttestwiringshouldbeexactlythesameastherelativephaserelationship(thephaserelationshipconvertedtotheprimaryside)ofthevoltageandcurrenttransformerconnectedtothepanelcabinetintheactualoperationwiring.2)Duringthesettinginspection,exceptthattheincomingACcurrentandvoltagearesimulatedfaultvalues​​andthetrippingandclosingcircuitsofthecircuitbreakeraredisconnected,theentiresetofprotectiondevicesshouldbeunderconditionsthatarecompletelyconsistentwiththeactualoperatingconditions,andmustnotbeused.artificiallyalteredduringtheexperiment.3)Thesetactiontimeoftheprotectiondeviceisthetotaltimefromtheintroductionofthesimulatedfaultcomponent(current,voltageorcurrentandvoltage)totheprotectionpanelcabinettotheprotectionactionsendingthetrippulsetothecircuitbreaker.4)Theinspectionitemsandcontentsoftheelectricalcharacteristicsshallbeformulatedaccordingtothenatureoftheinspection,thespecificstructureandoperationprincipleoftheprotectiondevice.Whencheckingthecharacteristicsoftheprotectiondevice,inprinciple,itshouldmeettheactualoperatingconditionsandmeettherequirementsofactualoperation.Eachinspectionitemshouldhaveaclearpurpose,ornecessaryforoperation,ortodeterminewhethercomponentsanddevicesareingoodconditionandtofindpossibledefects.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples6.SettinginspectionoffixedvalueDuringperiodicinspectionandacceptanceinspectionofnewlyinstalledprotectivedevices,theset-upinspectionrequirementsofthedeviceareasfollows1)Duringtheacceptanceinspectionofthenewlyinstalledprotectiondevice,eachfunctionalelementoftheprotectionshouldbeinspectedonebyoneaccordingtothesettingitemsonthevaluenotice,thedevicetechnicalspecificationorthetestmethodrecommendedbythemanufacturer.2)Duringallinspections,onlyoneoftheprotectionelementscomposedofdifferentprinciplesneedstobeinspected.Itisrecommendedtocheckthesettingitemsofthemainprotection,andthebackupprotectionsuchasphaseone,two,andthreeimpedanceprotectionsonlyneedtoselectanysettingitemforinspection.3)Partialinspectionsmaybecarriedoutincombinationwiththeentiresetoftestsoftheprotectivedevice.BasictestmethodforrelayprotectionBasictestmethodsforrelayprotectionareexamples7.Wholesetoftrials1)Aftercompletingthesettinginspectionofeachsetofindividualprotections(components),itisneces

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论