2023 地热废弃井及长停井处置规范_第1页
2023 地热废弃井及长停井处置规范_第2页
2023 地热废弃井及长停井处置规范_第3页
2023 地热废弃井及长停井处置规范_第4页
2023 地热废弃井及长停井处置规范_第5页
已阅读5页,还剩20页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

地热废弃井及长停井处置规范DisposalcodeabandonmentandinactiveofgeothermalwellsNB/T11155-2023目次前言······························································································································II1234567891范围·························································································································1规范性引用文件··········································································································1术语与定义················································································································1地热废弃井及长停井处置风险分类··················································································1地热废弃井及长停井封堵作业的目的···············································································2封堵井筒结构·············································································································2封井设计及工艺方法····································································································6质量检验···················································································································8井口处置要求·············································································································90资料存档要求············································································································9附录A(资料性)废弃井/长停井基本情况········································································10附录B(资料性)废弃井/长停井封井验收备案··································································12I地热废弃井及长停井处置规范1范围封井设计及工艺方法、质量检验、井口处置要求及资料存档要求。本文件适用于地热能开发利用项目的地热废弃井及长停井的处置。2规范性引用文件文件。GB/T11615地热资源地质勘查规范NB/T10709地热井钻完井工程验收规范SY/T5587.14常规修井作业规程第部分:注塞、钻塞333术语与定义下列术语和定义适用于本文件。地热废弃井geothermalabandonedwell按程序履行了报废审批手续或批准核销的永久性废弃的地热井。地热长停井geothermallongstop无法正常生产,长期停止使用,但尚未履行报废或核销的地热井。4地热废弃井及长停井处置风险分类地热废弃井及长停井处置风险分类见表1照较高的等级确定风险。表1风险分类表评价准则风险类别一类二类井口压力是否含有油/气层间干扰00<井口压力<4MPa含有油/气不含油/气层间不干扰,不存在层间窜层间存在沟通,存在窜层1表1风险分类表(续)评价准则风险类别一类无二类有有毒有害气体目的层热突破现象无有5地热废弃井及长停井封堵作业的目的地热井部分井段或全部井段的永久性封堵废弃或长停作业,主要措施是在井内适当层段注水泥塞,环境。6封堵井筒结构6.1一类废弃井封堵井筒结构666.1.1一类废弃井应自下而上,分别封堵泵室段套管鞋下部井段、套管鞋上部井段和井口。.1.2套管鞋下部和上部井段封堵的水泥塞长度应大于50m;井口封堵的水泥塞长度应大于100m。.1.3一类地热井主要有三种完井方式:裸眼完井、滤水管完井和套管射孔完井,按照完井方式,推荐一类废弃井的封堵井筒结构分别如图1、图2和图3a)封堵前的井筒结构)封堵后的井筒结构图1一类废弃井裸眼完井方式的封堵井筒结构2a)封堵前的井筒结构)封堵后的井筒结构图2一类废弃井滤水管完井方式的封堵井筒结构a)封堵前的井筒结构)封堵后的井筒结构图3一类废弃井套管射孔完井方式的封堵井筒结构36.1.4一类废弃井的目的热储层可采用无污染的砾料进行填砾并封堵目的热储层,填砾砾料应回填至热储层顶部,黏土层从热储层顶部回填,起到止水作用,黏土层段长应大于50m,如图4a)封堵前的井筒结构)封堵后的井筒结构图4一类废弃井热储层采用填砾工艺封堵的井筒结构.2二类废弃井封堵井筒结构6666.2.1.2.2200m以上。.2.3滤水管完井的地热井应全部封堵采用滤水管的井段,且高于所开采的热储层顶部深度200m以上。666.2.4套管射孔完井的地热井应全部封堵射孔井段,且高于射孔位置顶部深度200m以上。.2.5套管鞋下部和上部井段封堵的水泥塞长度应大于50m;井口封堵的水泥塞长度应大于100m。.2.6推荐一类废弃井的封堵井筒结构如图5、图67所示。4a)封堵前的井筒结构)封堵后的井筒结构图5二类废弃井裸眼完井方式的井筒结构a)封堵前的井筒结构)封堵后的井筒结构图6二类废弃井滤水管完井方式的井筒结构5a)封堵前的井筒结构)封堵后的井筒结构图7二类废弃井套管射孔完井方式的井筒结构.3一类长停井封堵井筒结构6一类长停井井筒结构封堵参考6.1.4二类长停井封堵井筒结构6二类长停井井筒结构封堵参考6.27封井设计及工艺方法7.1前期准备7.1.1收集相关资料,包括地热井的成井时间、井型、井身结构、井下管柱、地层情况(水层分布、(含邻井情况)、目前井口现状及温度、压力、水量、地面情况、废弃原因等。77.1.2对待封堵井进行处置风险等级评价,并采取对应的封堵方案。.1.3需要封堵的地热井,应进行全井筒通井、井下处理及相关测试工作,落实井筒状况,为封井设计提供基础参数。7.2封井设计77.2.1封堵地热井的水泥选用和配制,应按SY/T5587.14的规定执行。.2.2一类井井底温度在90P.O42.590℃以上时,宜使用P.O52.5或以上标号的水泥,并加入抗温剂。77.2.3二类井应采用油气专用的G级水泥进行封堵;当井底温度大于90℃时,应加入抗温剂。.2.4单段封井水泥塞长度应大于50m,井口水泥塞长度应大于100m。67.2.5注水泥塞施工时,井内的静液柱压力应大于地层压力。难以实现静态平衡的高压地层或漏失地层可采用桥塞、膨胀封隔器、水泥承留器等一些机械工具进行挤注水泥浆。77.2.6一开次完钻的废弃地热井宜采用全井灌注水泥进行封堵。.2.7周边存在采灌井干扰的废弃井封固前,应暂停周边干扰井的采水或回灌等作业,待地层压力稳定后,对可能存在井间干扰的层位进行挤注封堵。77.2.8封堵井的每个水泥塞均应探明准确位置,且要求试压合格。.2.9封井设计要符合规定的健康、安全和环保要求。777.3封井方法.3.1套管鞋封隔.3.1.1水泥塞在套管鞋上下的长度应大于50m,如图8所示。图8顶替法的水泥塞封堵裸眼井结构示意图7.3.1.2水泥承留器法9量应填满水泥承留器以下50m的裸眼井段,且留在水泥承留器上部的水泥塞长度应大于50m。图9水泥承留器封堵裸眼示意图777.3.2裸眼井段内的封隔.3.2.1裸眼井段悬空水泥塞,一类井水泥塞需包含全部应封堵目的热储层,水泥塞长度封堵至目的热储层顶部和底部各50m以上;二类井井筒内水泥塞应封堵至目的热储层以上200m,如图10所示。.3.2.2裸眼井段井壁垮塌,施工管柱无法下至待封井段的井,可在井壁垮塌位置以上裸眼井段挤注7打水泥塞。垮塌深度较浅的井,从垮塌部位开始采取全井灌注水泥至井口进行封井。图10裸眼井段内封隔示意图7.3.3有套管井的封隔有套管的井筒,应在整个目的热储层段打一个悬空水泥塞来封堵,如图11所示。水泥塞位置应从目的热储层底部以下50m(或人工井底)到目的热储层顶部以上200m。图11悬空塞法封井示意图88质量检验.1检验方法每个水泥塞凝固后,采用探水泥塞面检验和压差检验的方法对封堵效果进行检验。8.2探水泥塞面使用油管、钻杆等工作管柱并与水泥塞相接触,加压5kN~10kN探两次。此时井内油管、钻杆等工作管柱的深度就是水泥塞的深度。88.3压差检验用水泥塞封堵后,下管柱或者整井筒进行泵注加压,使井内液柱压力慢慢超过被水泥塞封堵层的压力5MPa10MPa,稳压观察30min,压降不大于0.5MPa,加压检验合格。9井口处置要求9.1不留井口采用与成井资料相近的原状土进行回填,井盖覆土厚度不应低于当地冻土层厚度,且不得低于1m,使土地能够再利用,视情况设置相应标识。9.2留存井口9.2.1要求留存井口的地热废弃井和长停井,完成封井后保留井口装置,井口装置应露出地面,并用厚度不低于5mm的圆形钢板焊牢,钢板面上应用焊痕标注井号和封堵日期,做好标识。.2.2井口有压力和含气的地热井废弃井和长停井,封井后应安装简易井口,安装压力表和放气阀,做好标识,立碑、刻字、盖井口房,并定期进行监控、维护、保养。9110资料存档要求0.1记录、打水泥塞封堵记录、管柱结构等)应按要求的格式以永久性文件存档。0.2基本情况表可参照附录A的格式填写。110.3地热废弃井和长停井封堵工作完成后,应进行验收,验收时应提交以下资料:a)封井方案或施工设计书;b)施工记录;c)监理报告;d)隐蔽工程验收记录;e)见证取样试验记录;f)竣工验收报告。110.4验收合格的,可参照附录B的格式填写废弃井和长停井封井验收备案表。0.5验收不合格的,应采取补救措施。9附录A(资料性)废弃井/长停井基本情况表A.1废弃井/长停井基本情况表废弃井/长停井井号省(自治区、直辖市)区县废弃井/长停井类型地市废弃井/长停井地址建井时间所属单位联系人联系电话废弃/长停原因经度废弃/长停时间纬度井管(筒)基本情况附:井管(筒)平面位置图、结构图等10备注:1234567891.废弃井井号:按照成井时的井号填写。.废弃井类型:一类或二类。....废弃井地址:区县名称+乡镇+1...0.联系电话:手机号、座机号等。废弃原因:说明废弃原因。11112.3.经度:用度、分、秒表示,示例“494.纬度:用度、分、秒表示,示例“495.含水层结构特征、处理情况等。11附录B(资料性)废弃井/长停井封井验收备案表B.1废弃井/长停井封井验收备案表废弃井/长停井井号成井时间联系人电话纬度经度井深地下水类型封井回填日期封井回填实施单位详细地址建设单位封井回填方式验收结论监理单位日期:日期:日期:相关单位意见施工单位井权单位附:验收过程中形成的文档和影像资料12备注:1234567891.废弃井编号:同附录A。..电话:手机号、座机号等。..经度:用度、分、秒表示,示例“49.纬度:用度、分、秒表示,示例“49.地下水类型:孔隙水、裂隙水、岩溶水等。.井深:单位米(1位。.0.封井回填实施单位:封井回填实施单位全称。建设单位:责任单位全称。12.+“地市”+13.封井回填方式:根据实际情况,填写封井方式。14.验收结论:根据实际情况填写。13ꢀ互联网数据中心服务能力评价技术要求TechnicalrequirementsforservicecapabilityevaluationofInternetDataCenterYD/T4127-2023ꢀꢀꢀYD/T4127-2023目次HYPERLINKHYPERLINKHYPERLINK\l"br25"互联网数据中心服务能力分级(HYPERLINK\l"br25"F1-F5HYPERLINK\l"br25")HYPERLINK\l"br25"...............................7IYD/T4127-2023互联网数据中心服务能力评价技术要求1ꢀ范围标,提出了服务能力评价的划分要求。心)业务的专业化服务能力进行考量。2ꢀ规范性引用文件凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB50174数据中心设计规范YD/T2542互联网数据中心总体技术要求33ꢀ术语和定义下列术语和定义适用于本文件。.1ꢀ互联网数据中心(IDC)internetdatacenter利用相应的机房设施,以外包出租的方式为用户的服务器等互联网或其他网络相关设备提供放置、施,并提供安全保障措施。3.2ꢀIT设备ITequipmentIT系统,并为用户提供信息处理和存储、通讯等服务,同时支撑数据中心的监控管理和运行维护。注:IT设备的具体类型包括:----服务器类:例如机架式、刀片式(含机框)或塔式等不同形式服务器;存储类:包括磁盘阵列、SAN交换机等存储设备,以及磁带库、虚拟带库等备份设备;网络类:包括交换机、路由器,以及防火墙、VPN、负载均衡等各类专用网络设备;IT支撑类:主要包括用于运行维护的KVM、监控管理等附属设备。3.3ꢀ供配电系统powersystem1YD/T4127-2023用于提供满足设备使用的电压和电流,并保证供电的安全性和可靠性,主要包括以下设备类型:---供电设备,包括高、中和低压变压器、UPS、蓄电池和高压直流等;配电设备,包括列头柜、PDU等;后备电源,包括柴油发电机等。3.4ꢀ互联网数据中心服务能力Internetdatacenterservicecapability能力、运营管理能力、网络运营能力和服务品质提供能力等。4ꢀ缩略语下列缩略语适用于本文件。CDNDCIMIT内容分发网络contentdeliverynetwork数据中心基础设施管理DataCenterInfrastructuremanagement信息技术informationtechnologyITassetmanagementITAMKVMPDUSANUPSVPNIT资产管理基于内核的虚拟机电源分配单元存储区域网络不间断电源kernel-basedvirtualmachinepowerdistributionunitstorageareanetworkuninterruptedpowersupplyvirtualprivatenetworks虚拟专用网络5ꢀ互联网数据中心服务能力评价概述互联网数据中心服务能力评价从运营能力、服务品质提供能力等方面提出了对服务商的总体要求,评价体系的整体内容如表1所示;互联网数据中心服务能力的等级为F1-F5,其中F1为最低等级,F5为最高等级。表1.评价体系框表运营能力关键基础设施运营保障能力运营管理能力网络运营能力供配电系统运营保障能力制冷系统运营保障能力消防系统运营保障能力安防系统运营保障能力弱电系统运营保障能力综合布线运营保障能力信息安全管理能力日常运行管理能力其他运维管理能力内部网络互联网络质量服务品质提供能力服务支持服务资质服务产品技术能力流程与规范2YD/T4127-2023主动反馈处理流程组织架构及人员配置人员资质企业资质国际认证国内认证基础服务产品产品定制化能力商务流程完整性服务保障时间事故处理速度主动反馈机制措施落地情况培训及考核对外服务SLA完运维人员稳定度合作方的管理自动化运维工具备程度6ꢀ服务能力技术指标66.1ꢀ关键基础设施运营保障能力.1.1ꢀ供配电系统电气系统运营保障能力评价指标包括:a)日常巡检,包括日常巡检制度及巡检内容要求、巡检记录或巡检报告、辅助智能巡检手段等;b)专项检查,包括:123456))))))供配电系统市电、变压器、不间断电源等设备负载率安全性检查;断路器整定值检查;仪表准确性定期校准、检查;年度设备灰尘清扫;设备运行状态安全性检查,配电柜有无异响、蓄电池有无膨胀变形等内容;定期检查开关、线缆、接头运行温度;c)设备性能测试检查,包括蓄电池年度放电测试、UPS电容性能检查及到期更换、ATS和母联自动切换功能测试、储油罐内燃料定期更新替换;d)设备维保,包括日常维护计划和专业维保合同,如发电机、UPS等;e)数据中心后备电力系统保障能力;f)时长。6.1.2ꢀ制冷系统制冷系统运营保障能力评价指标包括:a)巡检手段等;b)专项检查,包括:123456))))))制冷系统冷机、空调等设备负载率安全性检查;系统设定参数检查,根据运行环境条件选择设定最优的运行参数;仪表准确性定期校准、检查;空调送风气流组织、冷热通道封闭密闭性、局部热点检查;设备运行状态安全性检查,电动阀、手动阀实验性功能测试,冷塔结垢及效率等;定期水质专项测试检查;3YD/T4127-2023c)设备性能测试检查,包括:123)))冷机系统效率检查,根据运行参数提前安排冷机检修维护;空调送风效率检查,定期更换滤网;自控系统关键功能测试检查;d)设备维保,包括日常维护计划和专业维保合同,如冷机、水泵、空调等;e)的频率及时长。6.1.3ꢀ消防系统消防系统运营保障能力评价指标包括:a)人员是否有消防相关资质、消防事故预防机制及处理能力等;b)服务商在规定的时间段内,运营的数据中心及所在园区内发生火灾的频率影响范围。666.1.4ꢀ安防系统安防系统运营保障能力评价指标包括:a)服务商数据中心安全防卫机制及系统完备程度;b)服务商规定时间段内,数据中心发生的涉及设备和人员的安全事故的频率。.1.5ꢀ弱电系统弱电系统运营保障能力评价指标包括:a)服务商数据中心关键基础设施监控系统完备程度;b)服务商数据中心及园区闭路电视监控系统完备程度。.1.6ꢀ综合布线系统综合布线系统运营保障能力评价指标是数据中心内综合布线规范程度。66.2ꢀ运营管理能力.2.1ꢀ信息安全管理信息安全管理能力评价指标包括:a)服务商的信息系统安全管理机制完备程度,包括:123)))信息系统安全风险评价机制;信息系统安全风险识别机制;信息系统安全风险控制目标等管理机制。b)服务商的信息安全管理机制完备程度,包括:1234))))网络流量攻的监控及预警机制;数据中心网络稳定性保障机制;网络攻击行为发现及屏蔽机制;网络敏感信息(涉黄、涉毒、涉赌、反动等)筛查及屏蔽等机制。c)保密机制。6.2.2ꢀ日常管理4YD/T4127-2023设备及资源资产管理能力评价指标包括:a)服务商的资产管理流程及保障机制完备程度,包括:123)))完整的设备资产管理流程;与管理流程配套的ITAM设备资产管理系统;完整的设备生命周期管理机制等流程或管理机制。b)服务商数据中心资产管理措施的落实程度;c)服务商的变更管理措施及机制;d)服务商的容量管理措施及机制。6.2.3ꢀ其他运维管理机制其他运维管理补充机制评价指标包括:a)服务商数据中心应急管理流程及灾难演练机制的完备程度,包括:123)市电中断应急机制;)IT系统容灾方案;有完备的灾难演练机制。)b)服务商数据中心事故处理机制的完备程度。66.3ꢀ网络运营能力.3.1ꢀ网络质量评价网络质量评价指标包括:a)骨干网接入情况;b)网络接入间情况;c)线路冗余情况;d)网络到北上广深等一线城市、西北、西南等大型城市的端到端时延、模拟应用的性能情况。6.3.2ꢀ内部网络互联评价内部网络互联评价指标包括:a)面向数据中心不同用户联通的内部网络建设和管理能力。66.4ꢀ服务品质提供能力.4.1ꢀ服务资质服务资质完备程度评价指标包括:a)服务商企业资质完备程度;b)服务商获取认可程度。6.4.2ꢀ服务产品服务产品完备程度评价指标包括:a)服务商提供基础服务产品及增值服务产品的种类:123)))数据中心空间(机架

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论