已阅读5页,还剩4页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Factory Acceptance Test ReportProject: Panel Name: Panel NO. : Serial No. of Panel: Serial No. of Device: Device Type: DC Power Supply: VAC Voltage (nominal value): VRated Frequency: HzNR Electric Co., Ltd.69 Suyuan Avenue, Jiangning, Nanjing 211102, ChinaTel: +86 25 8717 8888 Fax: +86 25 8717 8999NR_S Catalog1. Target12. Purpose of Test13. Item of Test14. Test Equipments15. Test Carried Out By16. Content of Examination26.1 Sampling Test26.2 Binary Inputs Test26.3 Signal Contacts Test46.4 Output Contacts Test46.5 Logic Function Test56.5.1 Busbar Differential Protection (87B)56.5.2 Breaker Failure Protection of Busbar (50BF)61. TargetTarget Name: Busbar ProtectionProgram Version:2. Purpose of TestCheck the all function of relay. To ensure the function satisfy the requirement of Busbar Protection of this substation.3. Item of TestCheck the correctness of hardware and cable. Check the accuracy of sampling, and check binary input and binary output, signal contact, tripping contact, mechanic and so on. Check the logic function of each relay element and setting value.4. Test EquipmentsNo.Device NameDevice Type1Relay tester2Multimeter3Cross screwdriver4Straight screwdriver5. Test Carried Out ByNo.CompanyName1NR ELECTRIC CO.,LTD.2NR ELECTRIC CO.,LTD.346. Content of Examination6.1 Sampling TestCurrent Test Slots: 04&05AI Module: NR1401-12INo.ItemConfigured NameInject ValueSamplingResult1I12I23I34I45I56I67I78I89I910I1011I1112I12Slots: 06&07AI Module: NR1401-12INo.ItemConfigured NameInject ValueSamplingResult1I12I23I34I45I56I67I78I89I910I1011I1112I126.2 Binary Inputs TestSlots: 09BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_Pulse_GPS012BI_Print023BI_Maintenance034BI_RstTarg045EBI_Out_BBP056EBI_Out_BFP067BI_52b_Pha_Fdr07178BI_52b_Phb_Fdr07189BI_52b_Phc_Fdr071910BI_ManCls_Fdr072011BI_52b_Pha_Fdr082112BI_52b_Phb_Fdr082213BI_52b_Phc_Fdr082314BI_ManCls_Fdr0824Slots: 10BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_52b_Pha_Fdr01012BI_52b_Phb_Fdr01023BI_52b_Phc_Fdr01034BI_ManCls_Fdr01045BI_52b_Pha_Fdr02056BI_52b_Phb_Fdr02067BI_52b_Phc_Fdr02078BI_ManCls_Fdr02089BI_52b_Pha_Fdr030910BI_52b_Phb_Fdr031011BI_52b_Phc_Fdr031112BI_ManCls_Fdr031213BI_52b_Pha_Fdr041714BI_52b_Phb_Fdr041815BI_52b_Phc_Fdr041916BI_ManCls_Fdr042017BI_52b_Pha_Fdr052118BI_52b_Phb_Fdr052219BI_52b_Phc_Fdr052320BI_ManCls_Fdr052421BI_52b_Pha_Fdr062522BI_52b_Phb_Fdr062623BI_52b_Phc_Fdr062724BI_ManCls_Fdr0628Slots: 11BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_BFI_Fdr01012BI_BFI_Fdr02023BI_BFI_Fdr03034BI_BFI_Fdr04045BI_BFI_Fdr05056BI_BFI_Fdr06067BI_BFI_Fdr07078BI_BFI_Fdr08086.3 Signal Contacts TestSlots: B00 PWR Module: NR1301ANo.ItemTerminal No.Result1BO_Fail_1NR1301A_1-12BO_Alm_Abnor_1NR1301A_1-33BO_Fail_2NR1301A_4-54BO_Alm_Abnor_2NR1301A_4-66.4 Output Contacts TestSlots: 13BO Module: NR1547No.Name of contactTerminal No.Isolation LinksResult1BO_TrpFdr01_101-022BO_TrpFdr01_203-043BO_TrpFdr02_105-064BO_TrpFdr02_207-085BO_TrpFdr03_109-106BO_TrpFdr03_211-127BO_TrpFdr04_113-148BO_TrpFdr04_215-169BO_TrpFdr05_117-1810BO_TrpFdr05_219-2011BO_TrpFdr06_121-2212BO_TrpFdr06_223-2413BO_TrpFdr07_125-2614BO_TrpFdr07_227-2815BO_TrpFdr08_129-30Slots: 14BO Module: NR1547No.Name of contactTerminal No.Isolation LinksResult1BO_TrpFdr08_201-022BO_TrpBB_BBP_123-243BO_TrpBB_BBP_225-264BO_TrpBB_BFP_127-285BO_TrpBB_BFP_229-30Slots: 15BO Module: NR1548No.Name of contactTerminal No.Isolation LinksResult1BO_Alm_CTS_101-022BO_Alm_CTS_203-043BO_TrpBB_BBP17-184BO_TrpBB_BFP23-246.5 Logic Function Test6.5.1 Busbar Differential Protection (87B)(1)SettingsPick up setting of differential current: 4 A,slope setting(fixed): 0.5 ,(2)Pick up current of busbar differential protection testTest result of pick up current: A,(3)Slope testNo.Current of feeder 1Current of feeder 2Restraint currentDifferential current123456789 Slope calculation: Point 9 and point 5:K=( - )( - )= Point 8 and point 4:K=( - )( - )= Point 7 and point 3:K=( - )( - )= Operation time: ms(4)Function of CT circuit failure blocking BBP Function of CT circuit failure blocking BBP: Result: 6.5.2 Breaker Failure Protection of Busbar (50BF)(1)settingsPhase current setting: 2 A,Zero sequence current setting: 0.5 A,Negative sequence current setting: 0.5 A,Setting of time delay 0.5 S。(2)Breaker failure protection testTest result of current setting: A,Test result of zero sequence current setting: A,Test result of negative sequence current sett
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026编辑采访面试题及答案解析
- 2026编码算法面试题及答案
- 2026博物馆面试题目及答案
- 中国AI大模型市场大盘2026
- 二元一次方程组的解法(第1课时)课件2025-2026学年华师大版七年级数学下册
- 2026四川内江市隆昌市石燕桥镇李市小学招聘1人笔试题库含答案详解【黄金题型】
- 2026北京通州区65所中小学及幼儿园招聘啦笔试题库附完整答案详解【有一套】
- 2026辽宁盘锦市双台子区招聘公益性岗位人员88人参考题库含答案详解【突破训练】
- 2026广东茂名化州市招聘教师304人(编制)模拟试卷附答案详解(模拟题)
- 北京市昌平区清悦幼儿园诚聘英才备考题库及参考答案详解(A卷)
- 酒罐区安全生产制度
- 2026宁夏中考语文考前提分模拟卷含答案
- 2026中央安全生产考核巡查明查暗访应知应会手册及检查重点解析
- 南铁单招真题及答案2026
- uu跑腿行业数据分析报告
- 企业安全操作规程标准手册
- JJF 1139-2026 计量器具检定周期 确定原则和方法
- 渣土车运营公司管理制度
- 采购供应商黑名单管理制度
- 外贸企业形式发票(Proforma Invoice)-模板
- 2026年基金从业资格证考试题库500道附答案【考试直接用】
评论
0/150
提交评论