Factory Acceptance Test ReportProject: Panel Name: Panel NO. : Serial No. of Panel: Serial No. of Device: Device Type: DC Power Supply: VAC Voltage (nominal value): VRated Frequency: HzNR Electric Co., Ltd.69 Suyuan Avenue, Jiangning, Nanjing 211102, ChinaTel: +86 25 8717 8888 Fax: +86 25 8717 8999NR_S Catalog1. Target12. Purpose of Test13. Item of Test14. Test Equipments15. Test Carried Out By16. Content of Examination26.1 Sampling Test26.2 Binary Inputs Test26.3 Signal Contacts Test46.4 Output Contacts Test46.5 Logic Function Test56.5.1 Busbar Differential Protection (87B)56.5.2 Breaker Failure Protection of Busbar (50BF)61. TargetTarget Name: Busbar ProtectionProgram Version:2. Purpose of TestCheck the all function of relay. To ensure the function satisfy the requirement of Busbar Protection of this substation.3. Item of TestCheck the correctness of hardware and cable. Check the accuracy of sampling, and check binary input and binary output, signal contact, tripping contact, mechanic and so on. Check the logic function of each relay element and setting value.4. Test EquipmentsNo.Device NameDevice Type1Relay tester2Multimeter3Cross screwdriver4Straight screwdriver5. Test Carried Out ByNo.CompanyName1NR ELECTRIC CO.,LTD.2NR ELECTRIC CO.,LTD.346. Content of Examination6.1 Sampling TestCurrent Test Slots: 04&05AI Module: NR1401-12INo.ItemConfigured NameInject ValueSamplingResult1I12I23I34I45I56I67I78I89I910I1011I1112I12Slots: 06&07AI Module: NR1401-12INo.ItemConfigured NameInject ValueSamplingResult1I12I23I34I45I56I67I78I89I910I1011I1112I126.2 Binary Inputs TestSlots: 09BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_Pulse_GPS012BI_Print023BI_Maintenance034BI_RstTarg045EBI_Out_BBP056EBI_Out_BFP067BI_52b_Pha_Fdr07178BI_52b_Phb_Fdr07189BI_52b_Phc_Fdr071910BI_ManCls_Fdr072011BI_52b_Pha_Fdr082112BI_52b_Phb_Fdr082213BI_52b_Phc_Fdr082314BI_ManCls_Fdr0824Slots: 10BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_52b_Pha_Fdr01012BI_52b_Phb_Fdr01023BI_52b_Phc_Fdr01034BI_ManCls_Fdr01045BI_52b_Pha_Fdr02056BI_52b_Phb_Fdr02067BI_52b_Phc_Fdr02078BI_ManCls_Fdr02089BI_52b_Pha_Fdr030910BI_52b_Phb_Fdr031011BI_52b_Phc_Fdr031112BI_ManCls_Fdr031213BI_52b_Pha_Fdr041714BI_52b_Phb_Fdr041815BI_52b_Phc_Fdr041916BI_ManCls_Fdr042017BI_52b_Pha_Fdr052118BI_52b_Phb_Fdr052219BI_52b_Phc_Fdr052320BI_ManCls_Fdr052421BI_52b_Pha_Fdr062522BI_52b_Phb_Fdr062623BI_52b_Phc_Fdr062724BI_ManCls_Fdr0628Slots: 11BI Module: NR1502ASNo.Binary Input NameTerminalResult1BI_BFI_Fdr01012BI_BFI_Fdr02023BI_BFI_Fdr03034BI_BFI_Fdr04045BI_BFI_Fdr05056BI_BFI_Fdr06067BI_BFI_Fdr07078BI_BFI_Fdr08086.3 Signal Contacts TestSlots: B00 PWR Module: NR1301ANo.ItemTerminal No.Result1BO_Fail_1NR1301A_1-12BO_Alm_Abnor_1NR1301A_1-33BO_Fail_2NR1301A_4-54BO_Alm_Abnor_2NR1301A_4-66.4 Output Contacts TestSlots: 13BO Module: NR1547No.Name of contactTerminal No.Isolation LinksResult1BO_TrpFdr01_101-022BO_TrpFdr01_203-043BO_TrpFdr02_105-064BO_TrpFdr02_207-085BO_TrpFdr03_109-106BO_TrpFdr03_211-127BO_TrpFdr04_113-148BO_TrpFdr04_215-169BO_TrpFdr05_117-1810BO_TrpFdr05_219-2011BO_TrpFdr06_121-2212BO_TrpFdr06_223-2413BO_TrpFdr07_125-2614BO_TrpFdr07_227-2815BO_TrpFdr08_129-30Slots: 14BO Module: NR1547No.Name of contactTerminal No.Isolation LinksResult1BO_TrpFdr08_201-022BO_TrpBB_BBP_123-243BO_TrpBB_BBP_225-264BO_TrpBB_BFP_127-285BO_TrpBB_BFP_229-30Slots: 15BO Module: NR1548No.Name of contactTerminal No.Isolation LinksResult1BO_Alm_CTS_101-022BO_Alm_CTS_203-043BO_TrpBB_BBP17-184BO_TrpBB_BFP23-246.5 Logic Function Test6.5.1 Busbar Differential Protection (87B)(1)SettingsPick up setting of differential current: 4 A,slope setting(fixed): 0.5 ,(2)Pick up current of busbar differential protection testTest result of pick up current: A,(3)Slope testNo.Current of feeder 1Current of feeder 2Restraint currentDifferential current123456789 Slope calculation: Point 9 and point 5:K=( - )( - )= Point 8 and point 4:K=( - )( - )= Point 7 and point 3:K=( - )( - )= Operation time: ms(4)Function of CT circuit failure blocking BBP Function of CT circuit failure blocking BBP: Result: 6.5.2 Breaker Failure Protection of Busbar (50BF)(1)settingsPhase current setting: 2 A,Zero sequence current setting: 0.5 A,Negative sequence current setting: 0.5 A,Setting of time delay 0.5 S。(2)Breaker failure protection testTest result of current setting: A,Test result of zero sequence current setting: A,Test result of negative sequence current sett

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论