红外探测器英文说明书皇宫锦衣卫正品_第1页
红外探测器英文说明书皇宫锦衣卫正品_第2页
红外探测器英文说明书皇宫锦衣卫正品_第3页
红外探测器英文说明书皇宫锦衣卫正品_第4页
红外探测器英文说明书皇宫锦衣卫正品_第5页
已阅读5页,还剩7页未读, 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、LA-9V wireless passive infrared detector 1.General IntroductionThis is kind of infrared detector which is composed of world famous manufactured components, use stable and reliable technology, has test function for low voltage to warn user to exchange the batteries, and use blur logic micro-processin

2、g technology for better work state.( is the best),and should be installed at angle indoor as much as possible to achieve best effect, and should be keep some angle with indoor walk line(best at 90o to walk way direction) One way: use double stick on the wall, and proper glass stick is recommended (s

3、uitable for home installation)Another way: fix attached bracket with the screw hole on the detector bottom cover by screw, and press the infrared detector which installed with bracket into the round hole of bottom board, and regulate it to a best angle.(suitable for project installation)3. Cautions(

4、1) Dont face to window directly.(2) No obstacle, furniture, large plant or other obstacles in the detect scope.(3) Dont face to the window, cold or warm machine, fire stove,etc. such has quick temperature change in case the occurrence of mis-report.(4) Dont install two detectors in the same space in

5、 case that mis-report caused by disturbance.(5) 5 minutes recognizing time for the surrounding circumstance after start the detector, and dont use remote controller until after 5 minutes.(6) Seconds for confirmation when the detector detects some intruders, and then send alarm signal in case for mis

6、-report, or omit report.(7) Only installed indoor(can not be install outdoor, for example terrace)4. Functions(1) Alarm happensWhen the detector is in normal work state:1)When detect moving objects in the valid detect scope, and send alarm indicator to the main unit to process after editing code, th

7、e alarm indicator LED flashes as well as output alarm indication.2).Low voltage warning display, when power is lower than 2.7V, the alarm indicator light will flash and output alarm signal.(2) Edit code1-8 are digital-coding feet, A-D are addressing coding, it should edit code before installation.(3

8、) State regulationTEST is test end, JPA is for sensibility regulation.1) function for 2 ports: TEST JPAShort circuit Test stateHigh sensibilityCpen circuitUsing stateLow sensibilityNote: ! JPA is in open circuit state under normal condition.! Regulate TEST state to using state after over test or log

9、 in . 2) Regulation! Test state: testing state: enter into work state after connecting with electricity for 10 secs for the first time, delay 5secs to entering into work state after detect a signal spring.! Using state: enter into work state after connecting with electricity for 90 secs for the firs

10、t time, delay 40 secs to entering into work state after detect a signal spring.5. Technical parameters(1)(2) Static work current:32uA(3) Dynamic work current:7mA(4) Transmitting frequency: 433MHZ(5) Detector detect distance:6-8m(6) Detect angle: horizon angle 110o, vertical angle 90o(7) Transmitting

11、 distance:500m(no obstacle)LA-9BV wireless passive infrared detector1.General IntroductionLA-9BV is a hang wireless passive infrared detector, has high sensibility, low consumption wireless transmitting circuit and blur logic analyzed circuit.(1) ( is the best), put battery in the detectors and inst

12、alled bracket, regulate detect angle to achieve best effect.(2) Avoid sunshine to camera lens directly.(3) Avoid detector some moving objects like cloth, curtain, etc.;(4) Stay away from the objects which easily to cause temperature change such as air-condition, fan, refrigerator, oven.(1) The detec

13、tor is used for indoor, not for outdoor;(2) No obstacle, furniture, large plant or other obstacles in the detect scope.(3) Dont install two detectors in the same space in case that mis-report caused by disturbance.4.Alarm functions(1) spring alarm: when detector detects body moving and sends spring

14、alarm, the alarm indicator light is on for 1sec.(2) Low voltage alarm: when power voltage is lower 3.0V, the alarm indicator flash once every 2 secs, and send once low voltage alarm signal.(3) Damage alarm: when the detector is in normal use state, if somebody open detector, and K1 spring up, the al

15、arm indicator flash for secs and send damage alarm signal at the same time(K1 can be used as spring switch)5.Technical parameters(1) power: 3* 1.5V AA (4.5V)(2) work current: static current60uA Alarm current7mA(3) Transmitting frequency:433MHZ(4) Transmitting distance500m(no obstacle)(5) Sensor: low

16、 noise double components(6) Detect angle: horizon angle 110o, vertical angle 90o(7) detect distance: 6-8m(8) work state:Test state(K1 spring up when open cover, minimum interval between 2 alarms is 10secs.)Power-saving state(press K1 down when close cover, minimum interval between 2 alarms is 1 min.

17、)LA-9CV Passive infrared detector instruction 1.General introductionLA-9CA is one kind of wall suspension type wireless passive infrared detector, is composed with the low noise dual-components infrared set, the low power consumption wireless transmission circuit and the fuzzy logic analysis electri

18、c circuit .2.Main features1.pure wireless structures, convenient for installment and maintenance.2.super power saving + intelligence analysis design, has longer continuous working time than other wireless infrared detector. can expand 2,262 codes, and convenient to be compatible with main unit from

19、other company. 3.Technical parametersPower supply:3*1.5V AA alkalinity battery Work current:static current <30uA Alarm current<7mAElectricity self-checking: 10 seconds Operating frequencies: 433MHzTransmitting range:500m( no barrier )Detect angle:horizen110°vertical90Detect distance:9m(ty

20、pical)Low battery voltage:When the battery voltage is lower than 3V, the detector sending a low voltage alarm signal, the indicating lamp flash 2 times every 3 seconds.Work state:1)when“TEST”jump pin at disconnection state:damage alarm: when the detector is in normal use state, if somebody open dete

21、ctor, and K1 spring up, the alarm indicator flash for secs and send damage alarm signal at the same time(K1 can be used as spring switch);work state:Test state(K1 spring up when open cover, minimum interval between 2 alarms is 10secs.)Power-saving state(press K1 down when close cover, minimum interv

22、al between 2 alarms is 1 min.) 2)when“TEST”jump pin at short connection state: Without damage alarm function, and K1 is invalid, the minimum interval is 10secs however open or close the cover. 3)“LONG”is detect distance jump pin:long distance when short circuit, short distance when open circuit. 4)“

23、A”is detect sensibility jump pin:short circuit“2PUL”is high sensibility, short circuit“3PUL”is low sensibility, often use “2 PUL” at home to achieve high sensibility, and advise you to jump to “3 PUL” when big disturbance. 4. Installation1 Span: fixes the bracket on wall surface at 1.5 2.2 meters fr

24、om ground walls , installs battery to the detector and install on the bracket, adjust the detector angle appropriately to achieved needed survey space.2 Indicator light :(1)Electrocity self-checking: connect with power for 10secs, the indication light flash once for every second.(2)Spring alarm: the

25、 indicator light t ake a long flash for 1 sec (3)Low voltage: flash twice every 3 secs.5. Cautionst drop or hit the detector when installs, in order to avoid damage internal sensor.t touch the infrared sensor with hand in order to avoid dirt mirror surface.3.Avoid to using two or more detector as mu

26、ch as possible to avoid two detectors are triggered simultaneously and causes the main unit not to be able to receive the signal.voids surveying the moving objects like clothing, curtain and so on and keep far away objects may cause the temperature change such as the air conditioning, the ventilator

27、, the refrigerator, the oven as far as possible. 5.Keep away from metal object as much as possible to obtain the transmitting range.LA-9DV1.General introductionThis is infrared sensor detector, add outside power circuit, low voltage alarm function on the basis of LA-9BV, and improve the transmitting

28、 distance up to 1km.(1)power switchIt is DC 6V power supply under normal condition, when power interruption happens, the circuit will switch from outside power state to internal power state, and powered by backup power.(note: For this product has designed rechargeable function, so the rechargeable b

29、attery can be chosen)(2)alarmWhen detector in normal work state:1) When detector detects moving body and sends alarm indicator, send to the main unit after edit code for processing, and the alarm indicator light flashes for 1sec and send out alarm indicator.2)when somebody open the cover for damage,

30、 and K1 spring up and send out alarm, the alarm way is as same as above.3)Low voltage alarm: when power voltage is lower than 2.7V, the alarm indicator flashes and send out low voltage alarm signal.(3) Edit code:1-8 are digital-coding feet, A-D are addressing coding, it should edit code before insta

31、llation.(4)sensibility regulationTEST is test end, JPA is for sensibility regulation.: 1)TEST short circuit, it enters into normal work state after finishing test, it is in open circuit state(the default set is open circuit state, enter into normal work state after using test or log in and enter int

32、o a normal work state.)2)JPA is sensibility regulation: short circuit is high sensibility, open circuit is low sensibility, it is usually in open circuit state.3)When normal work state, need 1min for restart after the first time alarm(no acception of infrared spring), and enter into the second recei

33、ving work state, and then restart time is 3secs.3. Installation( is the best),and should be installed at angle indoor as much as possible to achieve best effect, and should be keep some angle with indoor walk line(best at 90o to walk way direction)One way: use double stick on the wall, and proper gl

34、ass stick is recommended (suitable for home installation)Another way: fix attached bracket with the screw hole on the detector bottom cover by screw, and press the infrared detector which installed with bracket into the round hole of bottom board, and regulate it to a best angle.(suitable for projec

35、t installation)4. Cautions(1)Dont face to window directly.(2)No obstacle, furniture, large plant or other obstacles in the detect scope.(3)Dont face to the window, cold or warm machine, fire stove,etc. such has quick temperature change in case the occurrence of mis-report.(4)Dont install two detecto

36、rs in the same space in case that mis-report caused by disturbance.(5)5 minutes recognizing time for the surrounding circumstance after start the detector, and dont use remote controller until after 5 minutes.(6)Seconds for confirmation when the detector detects some intruders, and then send alarm s

37、ignal in case for mis-report, or omit report.(7)Only installed indoor(can not be install outdoor, for example terrace)5.Technical parameters(2)Static work current:65uA±10uA(3)Dynamic work current:18mA±1mA(4)Transmitting frequency: 433MHZ(5)Detector detect distance:6-8m(6)Detect angle: hori

38、zon angle 110o, vertical angle 90oTransmitting distance:1000m(no obstacle) LW-618-2V Wireless Top curtain Infrared Detector1.General introductionLW-618-2 wireless top curtain infrared detector, uses double component infrared detection and the fuzzy logic analysis technology, its unique small angle p

39、assive lens, have characteristics high detection sensitivity , low mis-reporting rate , is the best detector uses in window, balcony, corridor place and so on 2.Technical parameters(1)power supply:4*1.5V AAA(2)work current: static current35uA alarm current8mA(3)transmitting frequencies: 433MHz(4)tra

40、nsmitting distance: 350m( no barrier)(5)work state:(1)test mode( when no bottom board or K1 spring up, the minimum alarm interval is 6secs.)(6)power-saving mode(install bottom seat or press K1 down, the minimum alarm interval is 1min)(7)sensors: Low noise double components(8)detect angles: Crosswise

41、 110° longitudinal 45°(9)detect distance: (10)self-checking time:10secs.Open the battery box back cover of detector, and put in batteries, screw the antenna from antenna mouth to the antenna seat, fix the foundation with the screw on the wall surface or ceiling. If install on the wall, hei

42、ght should be kept at 1.52m, and should be keep some angle with indoor walk line(best at 90o ). If install on the ceiling, it( is the best),and should be installed at angle indoor as much as possible to achieve the desired effect outside, and will have the antenna to face at the same time.(1) Becaus

43、e the detect coverage has extended(45°) compared with the ordinary curtain, therefore dont cover the range which has quick temperature change, such as outside window and electrical appliance place. If installs at window, balcony, channel, note dont approach the outside too nearly in order to av

44、oid mis-report.(2) There is 5 minutes sensation time to the environment when start the detector, it can be tested at this time, and the normal use should be better avoids this time.(3) This detector is in-door type, can not install at outside.(4) In the detect scope, it should not have screen, the f

45、urniture, the large-scale bonsai or other obstacle.(5) Dont install two detectors in the same space in case that mis-report caused by disturbance.5.Alarm functions(1)spring alarm: when detector detects body moving and sends spring alarm, the alarm indicator light is on for 1sec.(2)Low voltage alarm:

46、 when power voltage is lower 3.0V, the alarm indicator flash once every 2 secs, and send once low voltage alarm signal.(3)Damage alarm: when the detector is in normal use state, if somebody open detector, and K1 spring up, the alarm indicator flash for 1 sec and send damage alarm signal at the same

47、time(This functions can be used as log in)6.Technical parameters(1) power supply:4*1.5V AAA(2)work current: static current35uA alarm current8mA(3)transmitting frequencies: 433MHz(4)transmitting distance: 350m( no barrier)(6) work state: test mode( when no foundation or K1 spring up, the minimum alar

48、m interval between two alarms is 6secs.) power-saving mode( install foundation or press K1 down, the minimum alarm interval between two alarms is 1min)(7) detect angle: horizon 110° , vertical 45°(8) detect distance: (9) self-checking time:10secs.LW-618-2AV Instruction1.General introductio

49、nIt is a kind of wireless top curtain infrared detector, uses double component infrared detection and the fuzzy logic analysis technology, its unique small angle passive lens, have characteristics high detection sensitivity , low mis-reporting rate , is the best detector uses in window, balcony, cor

50、ridor place and so on 2.Main Features(1)Pure wireless structures, with simple installment and maintenance.(2)Power-saving+ intellectual analysis design, has more continuous working time than other wireless infrared detector.3.Tehnical parametersPower supply:4*1.5V AAA alkalinity batterywork current:

51、 static current30uA alarm current7mAtransmitting frequencies: 433MHztransmitting distance: 400m( no barrier)detect angle: wide angle110°curtain width:45°detect distance:(typical)low voltage of battery: when the battery voltage is lower than 3.9v, the detector send this signal to the main u

52、nit, then the indicator lamp flash 2 times in 3 secs, no work for other task. Damage alarm: If somebody get down the detector when the detector is in the normal work state, K1 spring up, alarm indicator lamp flash for 1sec and send a damage alarm at the same time(this function can be used as log in)

53、work state: test mode( when get down bracket(or K1 spring up, the minimum alarm interval between two alarms is 10secs.)power-saving mode( install bracket(press K1 down), the minimum alarm interval between two alarms is 1min)1. High stability installation guard4. Cautions(1)Dont reflect sunshine to c

54、amera lens directly.(2)Avoid detecting moving objects such as clothing, curtain, etc.(3)Stay away from quick temperature change objects such as air-condition, fan, refrigeratory,oven, etc.No obstacle, furniture, large plant or other obstacles in the detect scope.(4)Use high capacity alkali battery,

55、and achieve most stable state after connecting with power for 23days.Open the battery box back cover of detector, and put in batteries, screw the antenna from antenna mouth to the antenna seat, fix the foundation with the screw on the wall surface or ceiling. If install on the wall, height should be

56、 kept at 1.52m, and should be keep some angle with indoor walk line(best at 90o ). If install on the ceiling, it( is the best),and should be installed at angle indoor as much as possible to achieve the desired effect outside, and will have the antenna to face at the same time.Indicator lamp:(1) self

57、-check: connect with power for 10secs, and indicator lamp flash once every sec.(2) Spring up alarm: indicator lamp flash for 1 sec.(3) Low voltage: flash twice every 3secs.(1) Dont drop or hit the detector when installs, in order to avoid damage internal sensor.(2)Dont touch the infrared sensor with

58、 hand in order to avoid dirt mirror surface.(3) Avoid to using two or more detector as much as possible, or two detectors trigger simultaneously causes the main unit can not receive the signal.(4)The detector can be used for half outside, such as veranda, passage, etc.(5)The detect area is wider than common curtain(45°), please take

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论