版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、加气混凝土单一保温节能墙体体系的再议论顾同曾(北京市建筑设计研究院,北京 100045)摘 要 本文对加气混凝土单一保温节能墙体体系从我国不同气候区的使用、经济及技术方面进行了论述,得出了以下结论:加气混凝土制品作为单一墙体材料节能体系,运用不同密度和厚度的产品可以满足当前我国各个气候区规范对外墙的热工性能要求;与几种典型的外保温复合墙体相比,在采用近似墙厚和热工性能的前提下,无论社会效益和经济效益,单一墙体节能体系优势明显;从生产技术、配套构件及有关产品标准等方面看,、大力推广应用该节能体系的条件已经成熟;同时该体系也存在一定的问题,如在严寒地区,特别是A区的应用虽有优势,但不能简单地仅靠增
2、加墙厚来解决所有问题,还应补充其它措施。关键词 加气混凝土;单一保温节能墙体;气候区;经济;技术 中图分类号TU528.2 文献标识码 A Re-discussion on Aerated Concrete-based Single Insulation and Energy Efficiency Wall System GU Tong-zeng (Beijing Institute of Architecture Design, Beijing 100045, China)Abstract In this paper, aerated concrete single insulation a
3、nd energy efficiency wall system was demonstrated in the aspects of utility in different climate areas, economy and technology. It was concluded that as single insulation and energy efficiency wall system, aerated concrete with different densities and thicknesses could meet demands of thermal perfor
4、mance regulations in each climate area. Compared with typical heat preservation complex walls, the energy-saving effect of this system had obvious advantages, no matter for social and economic benefits, provided with almost same wall thickness and thermal performance. In consideration of production
5、techniques, supporting components and relative products standards, it was time to promote this energy efficiency system. Meanwhile, this system had disadvantages in cold area, although its application in A area had advantages, the problem could not be solved by increasing the wall thickness only, ot
6、her measures would also be needed.Keywords aerated concrete, single insulation and energy efficiency wall system, climate area, economy, technology2005年笔者曾在中国建设报发表过一篇题为应大力研发和应用单一保温墙体节能体系的拙作,旨在节约资源、简化施工工序、降低造价、充分利废、改善环境,推崇加气混凝土单一保温墙体的外墙节能体系。这种材料的发明起源于德国,他们在20世纪20年代研制了灰砂砖,即将磨细石灰和砂子经过混合、成型,高压养护制成一种实心砖以
7、替代传统的粘土砖。1924年瑞典人在这些材料中加入铝粉制成加气混凝土并于1929年以工业化方法进行生产,最初的商品名为“伊通”(YTONG,Y是这个厂址所在城市的第1个字母,TONG是瑞典文水泥的后缀)。而后,在瑞典又发展了另一种叫“西波列克斯”(siporex)品牌的加气混凝土。再后来,在德国、英国、荷兰等地发展了各种品牌的加气混凝土制品,尤其在二次收稿日期2008-08-15作者简介 顾同曾(1933-),男,大学,教授级高级建筑师联系方式 世界大战后,此种制品在世界各国大规模发展起来。用这种制品最早修建的建筑是于20世纪30年代初建于瑞典斯德哥尔摩远郊的1栋2层住宅,内承重墙和外墙均采用
8、B05级的产品,至今已有70多年的历史。我国于1965年引进了瑞典“siporex”专利,1967年正式投产,至今也已有40多年的历史(我国在引进国外专利之前已研发了这种产品,主要为板材,1966年在北京第三建筑公司修建了1栋由加气混凝土板材承重的3层宿舍楼,建筑面积为780 m2)。引进专利后,最早的产品也是板材,如屋面板应用于北京月坛一条街,大部分墙板应用于几个大型发电厂的外墙,如军粮城电厂、涉县电厂、娘子关电厂和包头106电厂(这一电厂外墙采用钢构构架和钢筋混凝土构架组装大板,每块板面积达20-30m2)。从20世纪70年代开始,北京大量推行这种节能墙体,主要是内外墙板,应用建筑有北京加
9、气厂办公楼、白家庄建材局的家属宿舍楼(这2栋建筑内外墙、屋面板、楼板都是加气混凝土制品),以及一大批高层住宅和公共建筑,如安定门小区、总参住宅、东大桥10楼、交通部住宅、糖业烟酒公司、储运公司仓库等;20世纪80年代修建了著名的大型公共建筑建筑面积达25 000 m2的国际展览中心,该建筑为一体化外墙,只是当时没有突出“节能”这个名称而已,在80年代北京加气混凝土厂建立了拼装大板生产线以及专用运输车辆,板材最大尺寸为6m×4.8m的大板;20世纪90年代,北京正式执行节能30%的标准,北京市建筑设计院与北京市加气混凝土三厂(后改名为北京现代建筑材料有限责任公司)合作,在北京市科委、建
10、委的支持下,由过去的仅使用加气构件发展成建筑体系。在该厂修建了1栋3 300 m2的6层“抗震、节能新体系住宅”:外墙采用B06级墙厚300 mm的加气混凝土砌块、屋顶采用加气混凝土屋面板、承重墙采用粉煤灰砖,该建筑的节能指标超过50,至今已使用16年有余,效果良好。 近20年来,加气混凝土行业在我国得到了很大发展,但人们心中仅把它看成是一种轻质墙体材料,很少把它与节能联系起来,甚至有些城市还不敢把它用作外墙。近10年来,各种外墙保温体系发展迅速,绝大部分都是复合墙体,即将保温材料复合在传统墙体材料的外表面或内表面,较为普遍采用的保温材料是泡沫聚苯乙烯板。保温墙体的应用无疑对我国建筑节能事业而
11、言是一大进步,但其所使用的保温材料的原材料属有机化工材料,大部分来源于石油,生产制造能耗高,随着油价和电价的飙升以及这种复合保温体系的施工较为复杂,难免造成工程质量中的许多问题。因此,反思我国几十年来建筑业的发展实践、克服现有复合体系的不足、充分认识加气混凝土单一墙体保温体系在建筑节能中的作用和发挥其独特的优势是具有现实和长远意义的。其优势表现为:1)我国大部分加气混凝土企业原材料主要是工业废料粉煤灰。我国煤炭资源丰富,火电是主要发电方式,粉煤灰资源丰富,分布面广。2)制造工业化程度高,产品质量有保证。3)施工简单、工序少且效率高。4)在造价方面比外保温复合体系有很大优势。5)耐久性好,如在瑞
12、典,20世纪30年代就开始使用,已有70多年的历史;原上海杨浦硅酸盐制品厂麻毅同志考证的上海国际饭店内墙和福州大楼外墙,使用年限基本和瑞典同步,也长达70余年。6)产品可一材多用:既可以做成板材(用作外墙、隔墙、屋面甚至于楼板),又可做砌块(用作外墙、内墙和隔墙),还可制造保温材料(用作屋面、地面以及复合外墙,尤其是近年研发出的B03、B04级轻质制品,保温特性更优化),最近又开发出的钢结构防火板,使其应用的领域更加广泛。笔者自2005年发表过以上观点后陆续听到各方面的意见和建议。本文就保温和墙体合一的保温体系作一些补充阐述。1、 在我国不同气候区使用是否可行保温和墙体合一的保温体系能否在全国
13、使用取决于材料性能能否符合各地不同气候区的节能标准。我国现行节能规范从建筑类型上分为“公共建筑”和“居住建筑”;按不同气候区来分,目前已发布的规范有章可循的分作4个地区:即夏热冬冷地区、夏热冬暖地区、寒冷地区和严寒地区(又分A区和B区);从节能率来看,可分为节能50%和个别城市节能65%地区,详见表13。可以看出,外墙传热系数K要求最高的是严寒地区A类公共建筑和居住建筑,要求K 0.4 W/(m2.K);要求最低的是夏热冬暖地区的居住建筑,当热惰性指标D 3.0时,其传热系数K仅要求为2.0 W/(m2.K)。当然这些数值也不是绝对的,最终以单位面积耗能量判定,各部位可以调整,但为便于对问题的
14、探讨,暂以此指标为界定值。由此再来审视各类级别、各种厚度的加气混凝土砌块墙的热工指标,能否满足上述要求。加气混凝土砌块墙的级别可分为B04B07级;墙厚可分为200500 mm,级别与厚度叠加品种繁多选择余地多样;墙体砌筑灰缝厚度可分为15 mm和3 mm共2种,详见表45。可以看出,墙厚40 0mm,灰缝3 mm的B04级砌块,其传热系数K就能达到0.37 W/(m2.K),满足严寒地区公共建筑和居居住建筑的传热系数指标(0.4 W/(m2.K))要求,此种砌块应用在其它地区当然更没有问题。 表1 公共建筑外墙传热系数K W/(m2.K)体形系数 0.3 0.3且 0.4 0.4夏热冬冷地区
15、 1.0夏热冬暖地区 1.5寒冷地区 0.6 0.5严寒地区B 0.5 0.45严寒地区A 0.45 0.40北京地区乙类 0.6 0.50 0.45甲类 0.8注:摘自公共建筑节能设计标准(GB 50189-2005)表-1;公共建筑节能设计标准(DBJ 01-621-2005)表-2和。 表2 居住建筑外墙传热系数K W/(m2.K)体形系数 0.3 0.3夏热冬冷地区K 1.5 D 3.0K1.0 D 2.5夏热冬暖地区K2.0 D3.0K1.0 D2.5K1.5 D3.0K0.7严寒及寒冷地区0.521.100.40.8注:1)摘自民用建筑节能设计标准(采暖居住建筑部分)(JGJ 26
16、-95);夏热冬冷地区居住建筑节能设计标准(JGJ 134-2001);夏热冬暖地区居住建筑节能设计标准(JGJ 75-2001)。2)本标准为节能50%指标。表3 北京居住建筑节能 设计标准(外墙部分)传热系数K W/(m2.K)4层及以上建筑0.6(外保温)特殊情况下采用内保温主体部位传热系数K0.33层及以下建筑0.45(外保温)不得采用内保温注:1)摘自居住节能设计标准(DBJ 11-6002-2006)中第3条和表。2)本标准为节能65%指标。表4 加气混凝土砌块墙厚级别及平均传热系数K W/(m2.K) 墙厚/mm B04级B05级B06级2000.670.782500.580.7
17、63000.593500.460.604000.420.484500.340.450.505000.310.38注:1)砌块灰缝不大于15 mm。2)灰缝修正系数为1.25。表5 加气混凝土砌块墙厚级别及平均传热系数K W/(m2.K)墙厚/mmB04级B05级B06级2000.590.680.762500.510.583000.450.573500.464000.370.420.474500.280.345000.250.31注:1)砌块灰缝不大于3 mm。2)灰缝修正系数为1.0。 由以上分析可知,加气混凝土墙作为单一保温墙体能满足当前全国各个地区的节能标准,那怕是最寒冷的严寒地区A的各类
18、建筑,但墙厚应为400 mm。按传统而言,在我国严寒地区墙厚通常为370 mm或490 mm,但当时是小砖砌筑,在技术上没有问题。而加气混凝土砌块体积大、份量重是否会给施工带来困难?这一问题也不难解决,砌筑时可分2层砌筑,如250 mm+150 mm或200 mm+200 mm,或用简单的机具吊装,在技术上也应该没有问题。与保温复合墙比,其缺点是,相对减薄墙厚、减少建筑面积、增大使用面积等方面有优势,而从单方造价来看,单一墙体占绝对优势。如何取舍还需要分析:损失使用面积(或加大建筑面积)合算?还是降低造价合算?这取决于投资者的决策。当然在技术上还有别的选择,即将加气混凝土墙也可做成复合墙,尤其
19、做内复合墙,优点十分明显,当然也可做成夹心保温墙。2、 在经济上是否可行笔者对全国建筑造价材料价格不太了解,仅就北京地区做过分析。将北京地区经常使用的4种墙体与保温板(EPS板)复合后的墙厚、热工性能和造价3方面与密度为B04、B05、B06级和砌筑灰缝不大于15 mm和不大于3 mm的不同加气混凝土墙厚作比较,发现同样墙厚、同样热工性能的单一墙体材料较为突出的是B05、B06级产品比复合墙体材料的造价要低45%左右,如当轻骨料混凝土和混凝土空心砌块复合墙的墙体厚度分别为275和288 mm、传热系数K 0.58 W/(m2.K)时,造价分别为142.90和147.59元/m2(其中防护层做法
20、已包括人工)。同样传热系数K 0.58 W/(m2.K),采用B05、B06级产品灰缝不大于3 mm,墙厚为325 mm的单一墙体造价分别为65.90和75.90元/m2,如采用B04级产品,灰缝不大于3 mm,墙厚为225 mm和275 mm的单一墙体,造价分别为75.90和89.10元/m2(其中材料费虽不包含人工费,但已包括砌筑砂浆和内外墙抹灰材料),详见表6。故在寒冷地区,如节能65%的北京地区,单一节能墙体在经济上占有绝对优势。表6 北京地区4种复合外保温墙体与加气混凝土单一墙体材性和价格比较墙厚/mm墙体价格EPS保温板厚度/mm保温层价格保温墙体总厚度/mm墙体传热系数K/(W/
21、(m2.K)墙体总价格/(元/m2)单方价格/(元/m3)每m2单价/(元/m2)保温层单价/(元/m2)防护层单价/(元/m2)每m2单价/(元/m2)KP1多孔砖24016539.006021.07899.03200.58138.00轻骨料混凝土空心砌块19022048.006622.778100.72750.58148.70混凝土空心砌块19023947.807024.578102.52850.57150.30混凝土墙体180236.7543.007024.578102.52700.59145.50加气混凝土砌块(B05、B06)(灰缝不大于15 mm)25020050.002750.7
22、6(B06)64.1030061.003250.59(B05)75.1040080.004250.48(B05)94.10加气混凝土砌块(B05、B06)(灰缝不大于3 mm)20020050.002250.68(B05)0.76(B06)62.7025061.002750.58(B05)71.9030080.003250.57(B06)82.70加气混凝土砌块(B04)(灰缝不大于15mm,.灰缝不大于3mm)20030060.00225(15缝)225(3缝)0.67(15缝)0.59(3缝)74.1075.9025075.00275(15缝)275(3缝)0.58(15缝)0.51(3缝
23、)89.1090.9030091.00325(15缝)325(3缝)0.45(3缝)105.5106.90350105.26375(15缝)375(3缝)0.46(15缝)119.30121.16400120.00425(15缝)425(3缝)0.42(15缝)0.37(3缝)134.10135.90注:1)B04级加气混凝土砌块售价300元/m3,灰缝不大于3 mm砌筑粘结剂用量为6.8 kg/m2,合6.8元/m2(单价1000元/t),外墙干粉抹灰砂浆用量为10.8 kg/m2,合5.4元/m2 (单价500元/t),内墙粉刷石膏用量为9 kg/m2,合3.7元/m2(单价410元/t)
24、,总的配套砂浆合15.9元/m2。表中墙体总价格已包含砌筑砂浆和内外墙抹灰。墙材价格摘自北京工程造价信息2008年2月刊。2)加气砌块灰缝不大于15 mm砌筑砂浆合5元/m2,加内外抹灰共14.1元/m2,表中墙体总价格已包含砌筑砂浆和内外墙抹灰。3)其它墙体外保温做法价格不包括内墙抹灰和砌体砌筑砂浆。4)加气砌块灰缝不大于3 mm的墙体热工性能与加气外墙板相同。5)热工数据摘自公共建筑节能构造(严寒和寒冷地区)(06J908-1),公共建筑节能构造(夏热冬冷和夏热冬暖地区)(06J908-2),蒸压加气混凝土砌块建筑构造(03J104)。6)本造价是去年数据随着经济危机的发生,保温材料价格有
25、所下降,但对总造价而言并不明显。3、 在技术上是否可行3.1 “热桥”问题“热桥”是保温体系普遍存在的问题,关键是什么样的“热桥”不允许?会产生结露的热桥是不允许的。与复合墙体相比,加气混凝土单一墙体的某些部位不存在“热桥”问题,如女儿墙、窗户外侧周边墙。当然,在梁、柱、构造柱等处,由于其外表面因2种不同材料处于同一表面所产生的“热桥”问题同样存在,若产生结露,也要解决。1)对于会产生结露的地区,一般是粘贴聚苯乙稀泡沫保温板,为防止界面处开裂,还需要特殊处理(如玻纤网格布聚合物水泥砂浆),比较麻烦。当前国外的处理方法是在该部位采用复合材料,外部为低密度加气混凝土薄板,内贴聚苯乙稀保温板的配件,
26、这样该部位的外表与墙体为同一材料。目前我国的生产水平已有可能生产这种配件,如将04级的产品(目前有些工厂已能生产B03级产品)切割成厚度为3 mm的薄片,工厂就可以专门制作解决“热桥”部位的复合外保温配件。2)加气混凝土的灰缝“热桥”问题应该注意。因为其热工性能好,所以墙身可以比较薄,但带来的问题是灰缝距离短,如用普通砂浆灰缝厚度,在该部位易产生“热桥”,解决方法有3种:一是采用具有一定保温性能的砌筑砂浆,如过去现代公司生产的AM1砌筑砂浆;二是采用密缝粘结砂浆,灰缝不大于3 mm,但前提是砌块尺寸必须精确;三是将墙加厚,但这要做各方面的分析。3)还有的“热桥”部位是出挑构件(如阳台的楼板、挡
27、板、分户墙板以及门头的雨罩、空调机搁板等),这也是保温体系的普遍问题。这一问题应从建筑设计的根本抓起,如有些可有可无的出挑构件能否取消?另外能否将构件与墙的面接触改成点接触以减少“热桥”面积?再一个方法是根据加气混凝土制品本身就是保温构件的特点,出挑的阳台楼板、挡板、雨罩等应该可以全部用加气混凝土板材解决。根据国外一些先进经验,把出挑部分作成一相对独立于建筑物之外,但又与主体结构拉结的构筑物,与主体结构“断桥”,如阳台、雨罩等,这不能不认为是一种较好的设计理念。3.2 墙厚问题从表16分析,加气混凝土墙作为单一保温节能墙体,在寒冷地区及其以南地区,在满足当地热工性能条件下,比复合墙体有优势,在
28、严寒地区也有相当优势,但A区,其传热系数K要达到0.4 W/(m2.K),如采用B04级加气混凝土单一材料则厚度要达到400 mm。而复合墙体最厚为340 mm(KP1多孔砖),最薄的仅为295 mm(混凝土墙),具体见表7。虽然单一材料在造价方面占优势,但至今还没有对严寒地区墙厚的限制规定。这里涉及的因素较多,有技术问题、经济问题以及施工等问题,只有通过一段实践以后才能做出定论。从理论上讲,根据严寒地区的传统习惯,墙厚在400 mm左右应该可以接受(据说某些严寒地区墙厚可放宽到不大于500 mm),这样,灰缝不大于15 mm的 B05级产品其传热系数K就能达到0.38 W/(m2.K),灰缝
29、不大于15 mm和不大于3 mm的B04级产品分别就能达到0.310.25 W/(m2.K)。如果一定要减薄,如前所述,加气混凝土也能做复合墙,尤其做内复合,不仅可以减薄墙厚,提高热工性能,还可以克服大部分“热桥”。如果墙体本身是保温材料,有些传统墙体材料的内外保温复合体系存在的“热桥”问题就不存在。内复合不但可以克服其它体系的各种缺点(如部分出挑构件以及灰缝的“热桥”),还可以带来其它的优点,如采用内复合后,在建筑外立面可以自由做各种附墙装饰(如线条、柱式、窗套、饰面砖等)且造价比外复合低得多,施工也简单得多,这些问题本人想再撰文论述。表7 复合墙厚与平均传热系数关系EPS板厚/mm墙总厚/
30、mm平均传热系数K/(W/(m2.K)190厚混凝土空心砌块952850.441103000.39240厚KP1多孔砖903300.431003400.39180厚混凝土墙1002800.431152950.38190厚轻集料混凝土空心砌块902800.451052950.39注:1)摘自国标图公共建筑节能构造(严寒及寒冷地区)(06J908-1)。2)墙厚未包括抹灰。至于在南方地区的应用优势,在此不再作赘述,它可以以最薄的墙身满足该地区的热工性能。在南方地区主要是解决隔热问题,虽然加气混凝土既有良好的保温性能又有良好的隔热性能,但同时满足传热系数K和热惰性指标D的要求是必要条件,因此在应用时
31、,需要对加气混凝土的密度作适当的调整。当然在南方地区除对围护结构要充分满足其热工性能外,还得在设计中考虑其它问题,如窗墙比、遮阳和通风等,这些也是十分重要的。3.3 墙面裂缝问题这一问题讨论已久,已有不少文章见诸报端,综合来看引起开裂的原因有以下方面:1)产品质量:如收缩和强度,根据东北建筑设计研究院冯堉生等同志的研究,粉煤灰制品自出釜含水率40%到平衡含水率5%,其收缩值仅为0.12 mm/m,经计算制品拉应力E0.12×10-3×1.75×1042.1 kg/cm2(式中,为制品拉应力,为制品变形值,E为制品弹性模量),而制品抗拉强度为2.5 kg/cm2(随
32、着生产技术的发展有些产品均高于此值),不会由于收缩使制品拉裂,除非是不合格产品。尤其在应用技术规范上将上房含水率作了限制,这就更减小了由材性收缩引起的墙体开裂的风险。2)建筑构造失当:如薄弱部位没有加强(如窗口下部、墙体角部)、2种不同材料的界面未作处理、墙身偏高过长以及结构变形对墙身的影响等。3)施工工艺:如上房含水率偏高、砌筑灰缝不够饱满(尤其是竖缝)、抹灰未按规程顺序及成品缺乏养护等。4)抹灰材料和砌筑砂浆、界面处理和缺损填补等所用材料的材性与加气混凝土材性不太相容等。经过几十年的研究,加气混凝土的应用技术几乎都有章可循。如北京建材院生产的外墙干粉料砂浆,其强度控制在4.07.0 MPa
33、,压折比不大于3.0,弹性模量为1 6002 000 N/mm2,与加气混凝土强度为2.04.0 MPa,干燥收缩值为不大于5×10-4相匹配,且这种砂浆具有较好的保水性(80%),符合加气混凝土的性能。在软件方面,相关标准、规程、图集均已陆续出版或正在报批、修订,已出版的有砌块标准、砌块国家标准图以及公共建筑国家标准图。各种配套材料和零部件有不少已投入工业化生产,如内外墙抹灰材料、锚固件、施工工具等都已投入市场。设计施工只要按规程、图集进行,按加气混凝土特性选用配套材料,墙体开裂是不难解决的。当前的问题是一旦出现墙面裂缝就不加分析,笼统地归罪于材料产品本身,这不是科学的态度,重要的
34、是加以分析,从实践来看,近年来这些问题都在逐渐克服。3.4 严寒地区应用问题加气混凝土的发展在我国寒冷及严寒地区发展的较早,如沈阳、长春、哈尔滨和齐齐哈尔等城市。但随着时间的推移,逐渐形成今天南盛北衰的局面,其主要原因之一是在发展材料生产技术的同时,忽视了对材料应用技术的研究。严寒地区较突出的问题是冻害,20世纪80年代笔者曾对东北地区进行过考察,建筑某些部位的破坏比较突出,如窗坎墙、檐口、凸出于外墙的装饰线脚、面砖等受冻害影响较大,但在同样处于严寒地区的北欧,笔者在考察中并没有见到这种情况,同样在日本北海道,此种材料应用广泛,主要是两个问题:一是构造不合理;二是构配件不配套,产品本身抗冻应该
35、没有问题。就加气材性而言,其饱水时抗冻性能良好。从最近北京现代公司开发的B04级产品的检测报告来看,强度为2.2 MPa,干密度为417 kg/m3的产品经抗冻试验,其质量损失仅为2%(标准值为5%),冻融后强度为1.9 MPa(标准值为不小于1.6 MPa),证明了它是较好的抗冻产品,存在的问题是这一产品受局部冻融易破坏。20世纪80年代,在我国寒冷及严寒地区对这一问题可能认识不足,如当时在东北地区,窗槛墙没有单框双玻或三玻窗,大部分采用两层单玻木窗,中间留出较大空隙,加之当时采暖制度大部分为间歇采暖,窗户玻璃上结的露水向两层单玻窗之间的空隙流淌,居民在其间放置锯末或毛巾,因无防水措施,窗台
36、和窗坎墙受局部冻融严重冻坏。同时灰缝“热桥”也相当严重(当然有些产品质量也太差),有些采用加气混凝土板出挑的檐口因无滴水构造破坏很严重,这些部分主要发生在春季,白天化,晚上冻。当然还有一些加气混凝土应用中的普遍问题,如抹灰问题、门窗及物件固定问题等。以上这些问题从今天技术发展的水平上来看都不应该是发展这一产品的障碍,不会影响在这些地区发展单一墙体节能体系。当然加气混凝土制品的应用除地区概念外,与建筑结构体系和商业经济观都有关系,如有些南方沿海地区地耐力差,但高层多,且大部分为框架结构,为减轻建筑自重用加气混凝土作填充墙是较佳的选择。现在不少多层和低层民居也用框架,底层商用,上层居住,这也是南方加气混凝土的发展比北方迅速的原因之一。3.5 强度问题为提高单一墙体的热工性能,减薄墙厚,在北方地区发展低密度加气混凝土制品是大势所趋。 目前北京B04级产品已能规模化生产,B03级产品也已开发成功。去年北京建材研究院修建了一座33 956 m2,高18 m的办公楼,外墙采用B04级产品,经检测该产品干密度为425 kg/m3,强度大于2.0 MPa,导热系数为0.09 W/(m.K),指标均高于蒸气加气混凝土砌块(GB 11968-2006)中的规定。此建筑墙厚为25 0mm,经计算其传热系数K=0.605 W/(m2.K),满足北京公共建筑甲
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 中国银行2025巴音郭楞蒙古自治州秋招笔试英语题专练及答案
- 邮储银行2025来宾市半结构化面试15问及话术
- 交通银行2025娄底市秋招结构化面试经典题及参考答案
- 建设银行2025鄂尔多斯市笔试英文行测高频题含答案
- 2025年3D打印的伦理争议
- 交通银行2025荆州市秋招笔试专业知识题专练及答案
- 2025行业市场规模增长动力分析
- 农业银行2025贺州市数据分析师笔试题及答案