2.开关量tcp-528a用户手册软件modbus rtu协议_第1页
2.开关量tcp-528a用户手册软件modbus rtu协议_第2页
免费预览已结束,剩余1页可下载查看

付费下载

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、福州格控电子有限公司PAGE 写DO多路开关量输出举例:模块地址=1:Modbus RTU格式: 十六进制主机发送DO:0- 3闭合:01 0F 00 00 00 04 01 FF 7E D6从机应答DO:0- 3闭合:01 0F 00 00 00 04 54 08 Modbus RTU=主机发送DO:0- 3断开:01 0F 00 00 00 04 01 00 3E 96从机应答DO:0- 3断开:01 0F 00 00 00 04 54 08 Modbus RTU=主机发送DO:0- 5闭合:01 0F 00 00 00 06 01 FF DF 16从机应答DO:0- 5闭合:01 0F

2、00 00 00 06 D5 C9 Modbus RTU=主机发送DO:0- 5断开:01 0F 00 00 00 06 01 00 9F 56从机应答DO:0- 5断开:01 0F 00 00 00 06 D5 C9 Modbus RTU=主机发送DO-0、1闭合,DO2-7断开:01 0F 00 00 00 08 01 03 BE 94从机应答DO-0、1闭合,DO2-7断开:01 0F 00 00 00 08 54 0D Modbus RTU=主机发送DO:0- 7闭合:01 0F 00 00 00 08 01 FF BE D5从机应答DO:0- 7闭合:01 0F 00 00 00 0

3、8 54 0D Modbus RTU=主机发送DO:0- 7断开:01 0F 00 00 00 08 01 00 FE 95从机应答DO:0- 7断开:01 0F 00 00 00 08 54 0D Modbus RTU=主机发送DO:0-11闭合:01 0F 00 00 00 0C 02 FF FF E4 00从机应答DO:0-11闭合:01 0F 00 00 00 0C 55 CE Modbus RTU=主机发送DO:0-11断开:01 0F 00 00 00 0C 02 00 00 E5 B0从机应答DO:0-11断开:01 0F 00 00 00 0C 55 CE Modbus RTU

4、=主机发送DO:0-15闭合:01 0F 00 00 00 10 02 FF FF E3 90从机应答DO:0-15闭合:01 0F 00 00 00 10 54 07 Modbus RTU=主机发送DO:0-15断开:01 0F 00 00 00 10 02 00 00 E2 20从机应答DO:0-15断开:01 0F 00 00 00 10 54 07 Modbus RTU=报文详解:主机发送的报文格式:发送内容字节数发送报文备注模块地址101H模块地址 = 1功能码10FH写寄存器 起始寄存器地址20000H起始寄存器地址:0000H - 开关量输出通道0的开关状态。 。0007H -

5、开关量输出通道7的开关状态该寄存器地址位于【0】区 数据发送顺序:高字节在前,如0007,则顺序:00 07开关量输出通道个数20008H8个输出开关量输出数据字节个数101H写入01个字节其中:01H = 通道个数 / 8 = 8 / 8如果个数8,且8,且=16,则字节数=2,发送报文=0302H,数据发送顺序为高字节在前:03 0203即表示:DO0-DO702即表示:DO8-DO15以此类推个数CRC校验2XXXXH前面所有数据的CRC校验数据发送顺序:低字节在前,如A050,则顺序:50 A0CRC计算软件厂家有提供从机应答的报文格式:发送内容字节数发送报文备注模块地址101H模块地

6、址 = 1功能码10FH写寄存器 起始寄存器地址20000H同“主机发送的报文格式”解析开关量输出通道个数20008H同“主机发送的报文格式”解析CRC校验2XXXXH前面所有数据的CRC校验数据发送顺序:低字节在前,如A050,则顺序:50 A0CRC计算软件厂家有提供写DO单路开关量输出举例:模块地址=1:Modbus RTU格式: 十六进制主机发送DO-0闭合:01 05 00 00 FF 00 8C 3A Modbus RTU从机应答DO-0闭合:01 05 00 00 FF 00 8C 3A Modbus RTU主机发送DO-0断开:01 05 00 00 00 00 CD CA M

7、odbus RTU从机应答DO-0断开:01 05 00 00 00 00 CD CA Modbus RTU=主机发送DO-1闭合:01 05 00 01 FF 00 DD FA Modbus RTU从机应答DO-1闭合:01 05 00 01 FF 00 DD FA Modbus RTU主机发送DO-1断开:01 05 00 01 00 00 9C 0A Modbus RTU从机应答DO-1断开:01 05 00 01 00 00 9C 0A Modbus RTU=主机发送DO-2闭合:01 05 00 02 FF 00 2D FA Modbus RTU从机应答DO-2闭合:01 05 00

8、 02 FF 00 2D FA Modbus RTU主机发送DO-2断开:01 05 00 02 00 00 6C 0A Modbus RTU从机应答DO-2断开:01 05 00 02 00 00 6C 0A Modbus RTU=主机发送DO-3闭合:01 05 00 03 FF 00 7C 3A Modbus RTU从机应答DO-3闭合:01 05 00 03 FF 00 7C 3A Modbus RTU主机发送DO-3断开:01 05 00 03 00 00 3D CA Modbus RTU从机应答DO-3断开:01 05 00 03 00 00 3D CA Modbus RTU=主机

9、发送DO-4闭合:01 05 00 04 FF 00 CD FB Modbus RTU从机应答DO-4闭合:01 05 00 04 FF 00 CD FB Modbus RTU主机发送DO-4断开:01 05 00 04 00 00 8C 0B Modbus RTU从机应答DO-4断开:01 05 00 04 00 00 8C 0B Modbus RTU=主机发送DO-5闭合:01 05 00 05 FF 00 9C 3B Modbus RTU从机应答DO-5闭合:01 05 00 05 FF 00 9C 3B Modbus RTU主机发送DO-5断开:01 05 00 05 00 00 DD

10、 CB Modbus RTU从机应答DO-5断开:01 05 00 05 00 00 DD CB Modbus RTU=主机发送DO-6闭合:01 05 00 06 FF 00 6C 3B Modbus RTU从机应答DO-6闭合:01 05 00 06 FF 00 6C 3B Modbus RTU主机发送DO-6断开:01 05 00 06 00 00 2D CB Modbus RTU从机应答DO-6断开:01 05 00 06 00 00 2D CB Modbus RTU=主机发送DO-7闭合:01 05 00 07 FF 00 3D FB Modbus RTU从机应答DO-7闭合:01

11、05 00 07 FF 00 3D FB Modbus RTU主机发送DO-7断开:01 05 00 07 00 00 7C 0B Modbus RTU从机应答DO-7断开:01 05 00 07 00 00 7C 0B Modbus RTU=主机发送DO-8闭合:01 05 00 08 FF 00 0D F8 Modbus RTU从机应答DO-8闭合:01 05 00 08 FF 00 0D F8 Modbus RTU主机发送DO-8断开:01 05 00 08 00 00 4C 08 Modbus RTU从机应答DO-8断开:01 05 00 08 00 00 4C 08 Modbus R

12、TU=主机发送DO-9闭合:01 05 00 09 FF 00 5C 38 Modbus RTU从机应答DO-9闭合:01 05 00 09 FF 00 5C 38 Modbus RTU主机发送DO-9断开:01 05 00 09 00 00 1D C8 Modbus RTU从机应答DO-9断开:01 05 00 09 00 00 1D C8 Modbus RTU=主机发送DO-10闭合:01 05 00 0A FF 00 AC 38 Modbus RTU从机应答DO-10闭合:01 05 00 0A FF 00 AC 38 Modbus RTU主机发送DO-10断开:01 05 00 0A

13、00 00 ED C8 Modbus RTU从机应答DO-10断开:01 05 00 0A 00 00 ED C8 Modbus RTU=主机发送DO-11闭合:01 05 00 0B FF 00 FD F8 Modbus RTU从机应答DO-11闭合:01 05 00 0B FF 00 FD F8 Modbus RTU主机发送DO-11断开:01 05 00 0B 00 00 BC 08 Modbus RTU从机应答DO-11断开:01 05 00 0B 00 00 BC 08 Modbus RTU=主机发送DO-12闭合:01 05 00 0C FF 00 4C 39 Modbus RTU

14、从机应答DO-12闭合:01 05 00 0C FF 00 4C 39 Modbus RTU主机发送DO-12断开:01 05 00 0C 00 00 0D C9 Modbus RTU从机应答DO-12断开:01 05 00 0C 00 00 0D C9 Modbus RTU=主机发送DO-13闭合:01 05 00 0D FF 00 1D F9 Modbus RTU从机应答DO-13闭合:01 05 00 0D FF 00 1D F9 Modbus RTU主机发送DO-13断开:01 05 00 0D 00 00 5C 09 Modbus RTU从机应答DO-13断开:01 05 00 0D

15、 00 00 5C 09 Modbus RTU=主机发送DO-14闭合:01 05 00 0E FF 00 ED F9 Modbus RTU从机应答DO-14闭合:01 05 00 0E FF 00 ED F9 Modbus RTU主机发送DO-14断开:01 05 00 0E 00 00 AC 09 Modbus RTU从机应答DO-14断开:01 05 00 0E 00 00 AC 09 Modbus RTU=主机发送DO-15闭合:01 05 00 0F FF 00 BC 39 Modbus RTU从机应答DO-15闭合:01 05 00 0F FF 00 BC 39 Modbus RT

16、U主机发送DO-15断开:01 05 00 0F 00 00 FD C9 Modbus RTU从机应答DO-15断开:01 05 00 0F 00 00 FD C9 Modbus RTU报文详解:主机发送的报文格式: 设置DO_0闭合,模块地址=1:发送内容字节数发送报文备注模块地址101H模块地址 = 1功能码105H写寄存器 起始寄存器地址20000H寄存器地址:0000H -开关量输出通道0的开关状态。 。0007H -开关量输出通道7的开关状态该寄存器地址位于【0】区数据发送顺序:高字节在前,如0007,则顺序:00 07写入数据2FF00H将FF00H写入0000H寄存器中FF00H:表示DO闭合0000H:表示DO断开数据

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论