版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
核电厂主控室应急可居留系统调试导则GuidelineforcommissioningofemergencyhabitabilitysystemofcontrolroomfornuclearpowerplantsNB/T20727-2024目次前言····························································································································II12345678范围·························································································································1规范性引用文件··········································································································1术语和定义················································································································1试验目的···················································································································2试验一般要求·············································································································2逻辑控制试验·············································································································2核电厂主控室应急可居留系统试验··················································································3文档记录及归档··········································································································5I核电厂主控室应急可居留系统调试导则12范围本文件规定了压水堆核电厂主控室应急可居留系统的试验条件、试验目的、试验内容及验收准则。本文件适用于压水堆核电厂主控室应急可居留系统调试。规范性引用文件下列文件中的内容通过文中的规范性引用而构成本文必不可少的条款。其中,注日期的引用文件,NB/T20145核电厂调试试验程序和报告编写规范NB/T20568核电厂主控室可居留性内漏试验EJ/T核空气净化系统的现场检验33术语和定义下列术语和定义适用于本文件。.1主控室正常通风空调系统normalventilationsystemofmaincontrolroom在核电厂正常运行模式下为主控室提供通风的系统,维持主控室可居留区域内适宜的温度和湿度,为设备的正确运行和人员提供适宜的环境。3.2主控室应急可居留系统emergencyhabitabilitysystemmaincontrol在核电厂设计基准事故工况下,通过投运应急新风过滤机组或非能动高压空气储罐为主控室提供备的正确运行和人员提供适宜的环境。3.3未过滤空气内漏量unfilteredin-leakageflow事故应急工况下未经主控室可居留区系统过滤而进入主控室可居留区的空气流量。44试验目的.1验证核电厂主控室应急可居留系统控制联锁逻辑、报警功能、仪表指示满足设计要求。144444.2验证核电厂主控室应急可居留系统新风机组性能满足设计要求。.3验证核电厂主控室应急可居留系统投运后温湿度满足设计要求。.4验证核电厂主控室应急可居留系统投运后主控室空气品质、微正压值满足设计要求。.5验证核电厂主控室应急可居留系统投运后主控室内漏量满足设计要求。.6验证核电厂主控室应急可居留系统储罐内气体品质、充气压力、储气量满足设计要求(如适用)。4.7验证核电厂主控室应急可居留系统向主控室供气流量、喷射器诱导流量、非能动过滤净化机组性能满足设计要求(如适用)。5试验一般要求555555.1电气、仪控等支持系统可用。.2调试使用的相关文件已经备齐,且应为经批准生效的最新版本文件。.3试验用仪器、仪表应经过校验和标定合格,并在有效期内。.4手动阀、自动调压阀、远程控制阀等设备具备支持本试验条件。.5风机、加热器、加湿器等设备具备支持本试验条件。.6试验风险分析已完成,并制定了安全防范措施。6逻辑控制试验666666666.1试验条件.1.1核电厂主控室或远程停堆站已具备显示核电厂应急可居留系统所有仪表数据和报警的功能。.1.2核电厂DCS系统已具备用于验证核电厂主控室应急可居留系统控制功能的条件。.1.3阀门、风机在主控室能进行操作和显示。.2试验内容及要求.2.1进行仪表通道试验,验证仪表信号能在主控室或远程停堆站正确显示。.2.2进行报警试验,验证报警值、报警信号满足设计要求。.2.3进行阀门、风机远程操作试验,验证阀门、风机可远程操作且正确显示设备运行状态。.2.4进行逻辑联锁试验,验证系统逻辑联锁正确且满足设计要求。27核电厂主控室应急可居留系统试验77777.1应急新风过滤机组试验(适用于采用应急新风过滤机组的核电厂).1.1试验条件.1.1.1主控室应急可居留系统具备投运条件。.1.2试验内容及要求.1.2.1手动触发主控室隔离信号,验证核电厂主控室应急可居留系统自动投运,设备动作逻辑和响应时间满足设计要求。777.1.2.2进行应急新风净化风机的性能试验,验证性能满足设计要求。.1.2.3进行应急新风过滤机组运行流量试验,验证流量满足设计要求。.1.2.4进行应急新风过滤机组的高效过滤器吸附效率试验,验证吸附效率满足设计要求,试验内容和要求可参见EJ/T791。7.1.2.5进行应急新风过滤机组的活性炭过滤器吸附效率试验,验证吸附效率满足设计要求,试验内容和要求可参见EJ/T。7777777.2温湿度试验.2.1试验条件.2.1.1主控室应急可居留系统具备投运条件。.2.1.2室外气象条件满足设计要求。.2.1.3相关系统运行满足试验要求。.2.2试验内容及要求.2.2.1在主控室应急可居留系统投运时,对主控室可居留区内的房间进行温湿度测量,确认其满足设计要求。77777.3主控室可居留区正压试验.3.1试验条件.3.1.1确认主控室可居留区压力边界已建立,相关系统运行满足试验要求。.3.2试验内容及要求.3.2.1测量主控室可居留区的压力值,验证主控室可居留区与相邻区域的微正压不低于设计要求值。777.4主控室空气品质检测.4.1试验条件.4.1.1主控室应急可居留系统具备投运条件。3777.4.2试验内容及要求.4.2.1取样监测主控室内空气品质,验证主控室空气品质满足设计要求。.5主控室内漏试验主控室内漏试验可参照20568执行,验证核电厂主控室应急可居留系统投运后未过滤空气内漏量满足设计要求。7777777.6储气罐充气试验(适用于采用非能动高压空气储罐的核电厂).6.1试验条件.6.1.1核电厂主控室应急可居留系统吹扫已完成。.6.1.2核电厂主控室应急可居留系统供气压空机具备供气条件。.6.1.3压空机出口空气品质应满足设计要求。.6.2试验内容及要求.6.2.1进行核电厂主控室应急可居留系统储气罐充气试验,验证充气流量、目标压力、储气量应满足设计要求。777777.6.2.2检测核电厂主控室应急可居留系统储气罐出口气体品质,验证气体品质应满足设计要求。.7供气流量和压力调节试验(适用于采用非能动高压空气储罐的核电厂).7.1试验条件.7.1.1核电厂主控室应急可居留系统具备投运条件。.7.2试验内容及要求.7.2.1在储气罐正常运行状态下,在不同的供气压力平台检测核电厂主控室应急可居留系统向主控室供气流量,验证其满足设计要求。7777777777.8首次自动投运试验(适用于采用非能动高压空气储罐的核电厂).8.1试验条件.8.1.1确认主控室可居留区边界的门都已关闭。.8.1.2确认所有主控室边界隔离阀满足试验要求。.8.1.3确认核电厂主控室正常通风空调系统运行状态满足试验要求。.8.2试验内容及要求.8.2.1手动触发主控室隔离信号,验证核电厂主控室正常通风空调系统自动停运。.8.2.2验证主控室边界隔离阀自动关闭,且响应时间满足设计要求。.8.2.3验证核电厂主控室应急可居留系统自动投运,设备动作逻辑和响应时间满足设计要求。.9风量平衡试验(适用于采用非能动高压空气储罐的核电厂)47777.9.1试验条件.9.1.1核电厂主控室应急可居留系统具备投运条件。.9.2试验内容及要求.9.2.1调节核电厂主控室应急可居留系统向主控室供气各支管调节风阀开度,使各支管流量满足设计要求。77777777777.9.2.2检测核电厂主控室应急可居留系统向主控室供气流量,验证流量满足设计要求。.9.2.3检测核电厂主控室应急可居留系统喷射器诱导流量,验证流量满足设计要求。.10性能试验(适用于采用非能动高压空气储罐的核电厂).10.1试验条件.10.1.1主控室热负荷满足试验要求。.10.1.2核电厂主控室应急可居留系统储气罐储气量满足试验要求。.10.1.3试验前需连续监测主控室可居留区温度和湿度,温度和湿度均满足设计要求。.10.1.4试验前需连续监测主控室周围房间内温度,温度均满足设计要求。.10.1.5主控室内已按设计要求布置数量足够的热电偶和数据连续采集装置。.10.2试验内容及要求.10.2.1在核电厂主控室应急可居留系统投运状态下,测量主控室内平均温度、温升,验证主控室内平均温度、温升均满足设计要求。7777.10.2.2测量主控室内湿度数据,验证主控室内湿度均满足设计要求。.10.2.3测量主控室内二氧化碳气体浓度,验证主控室内二氧化碳浓度满足设计要求。.10.2.4测量主控室内噪声水平数据,验证主控室内噪声水平满足设计要求。.10.2.5进行非能动过滤净化机组性能试验,验证其性能满足设计要求,试验内容和要求可参见EJ/T791。7.10.2.6按设计要求连续采集温度、湿度、二氧化碳浓度等试验数据,验证核电厂主控室应急可居留系统满足设计要求。8文件记录及归档应对试验记录和报告按NB/T20145进行编制及归档。5参考文献[1]NB/T20395主控室可居留性设计要求_________________________________6ꢀ互联网数据中心服务能力评价技术要求TechnicalrequirementsforservicecapabilityevaluationofInternetDataCenterYD/T4127-2023ꢀꢀꢀYD/T4127-2023目次HYPERLINKHYPERLINKHYPERLINK\l"br17"互联网数据中心服务能力分级(HYPERLINK\l"br17"F1-F5HYPERLINK\l"br17")HYPERLINK\l"br17"...............................7IYD/T4127-2023互联网数据中心服务能力评价技术要求1ꢀ范围标,提出了服务能力评价的划分要求。心)业务的专业化服务能力进行考量。2ꢀ规范性引用文件凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB50174数据中心设计规范YD/T2542互联网数据中心总体技术要求33ꢀ术语和定义下列术语和定义适用于本文件。.1ꢀ互联网数据中心(IDC)internetdatacenter利用相应的机房设施,以外包出租的方式为用户的服务器等互联网或其他网络相关设备提供放置、施,并提供安全保障措施。3.2ꢀIT设备ITequipmentIT系统,并为用户提供信息处理和存储、通讯等服务,同时支撑数据中心的监控管理和运行维护。注:IT设备的具体类型包括:----服务器类:例如机架式、刀片式(含机框)或塔式等不同形式服务器;存储类:包括磁盘阵列、SAN交换机等存储设备,以及磁带库、虚拟带库等备份设备;网络类:包括交换机、路由器,以及防火墙、VPN、负载均衡等各类专用网络设备;IT支撑类:主要包括用于运行维护的KVM、监控管理等附属设备。3.3ꢀ供配电系统powersystem1YD/T4127-2023用于提供满足设备使用的电压和电流,并保证供电的安全性和可靠性,主要包括以下设备类型:---供电设备,包括高、中和低压变压器、UPS、蓄电池和高压直流等;配电设备,包括列头柜、PDU等;后备电源,包括柴油发电机等。3.4ꢀ互联网数据中心服务能力Internetdatacenterservicecapability能力、运营管理能力、网络运营能力和服务品质提供能力等。4ꢀ缩略语下列缩略语适用于本文件。CDNDCIMIT内容分发网络contentdeliverynetwork数据中心基础设施管理DataCenterInfrastructuremanagement信息技术informationtechnologyITassetmanagementITAMKVMPDUSANUPSVPNIT资产管理基于内核的虚拟机电源分配单元存储区域网络不间断电源kernel-basedvirtualmachinepowerdistributionunitstorageareanetworkuninterruptedpowersupplyvirtualprivatenetworks虚拟专用网络5ꢀ互联网数据中心服务能力评价概述互联网数据中心服务能力评价从运营能力、服务品质提供能力等方面提出了对服务商的总体要求,评价体系的整体内容如表1所示;互联网数据中心服务能力的等级为F1-F5,其中F1为最低等级,F5为最高等级。表1.评价体系框表运营能力关键基础设施运营保障能力运营管理能力网络运营能力供配电系统运营保障能力制冷系统运营保障能力消防系统运营保障能力安防系统运营保障能力弱电系统运营保障能力综合布线运营保障能力信息安全管理能力日常运行管理能力其他运维管理能力内部网络互联网络质量服务品质提供能力服务支持服务资质服务产品技术能力流程与规范2YD/T4127-2023主动反馈处理流程组织架构及人员配置人员资质企业资质国际认证国内认证基础服务产品产品定制化能力商务流程完整性服务保障时间事故处理速度主动反馈机制措施落地情况培训及考核对外服务SLA完运维人员稳定度合作方的管理自动化运维工具备程度6ꢀ服务能力技术指标66.1ꢀ关键基础设施运营保障能力.1.1ꢀ供配电系统电气系统运营保障能力评价指标包括:a)日常巡检,包括日常巡检制度及巡检内容要求、巡检记录或巡检报告、辅助智能巡检手段等;b)专项检查,包括:123456))))))供配电系统市电、变压器、不间断电源等设备负载率安全性检查;断路器整定值检查;仪表准确性定期校准、检查;年度设备灰尘清扫;设备运行状态安全性检查,配电柜有无异响、蓄电池有无膨胀变形等内容;定期检查开关、线缆、接头运行温度;c)设备性能测试检查,包括蓄电池年度放电测试、UPS电容性能检查及到期更换、ATS和母联自动切换功能测试、储油罐内燃料定期更新替换;d)设备维保,包括日常维护计划和专业维保合同,如发电机、UPS等;e)数据中心后备电力系统保障能力;f)时长。6.1.2ꢀ制冷系统制冷系统运营保障能力评价指标包括:a)巡检手段等;b)专项检查,包括:123456))))))制冷系统冷机、空调等设备负载率安全性检查;系统设定参数检查,根据运行环境条件选择设定最优的运行参数;仪表准确性定期校准、检查;空调送风气流组织、冷热通道封闭密闭性、局部热点检查;设备运行状态安全性检查,电动阀、手动阀实验性功能测试,冷塔结垢及效率等;定期水质专项测试检查;3YD/T4127-2023c)设备性能测试检查,包括:123)))冷机系统效率检查,根据运行参数提前安排冷机检修维护;空调送风效率检查,定期更换滤网;自控系统关键功能测试检查;d)设备维保,包括日常维护计划和专业维保合同,如冷机、水泵、空调等;e)的频率及时长。6.1.3ꢀ消防系统消防系统运营保障能力评价指标包括:a)人员是否有消防相关资质、消防事故预防机制及处理能力等;b)服务商在规定的时间段内,运营的数据中心及所在园区内发生火灾的频率影响范围。666.1.4ꢀ安防系统安防系统运营保障能力评价指标包括:a)服务商数据中心安全防卫机制及系统完备程度;b)服务商规定时间段内,数据中心发生的涉及设备和人员的安全事故的频率。.1.5ꢀ弱电系统弱电系统运营保障能力评价指标包括:a)服务商数据中心关键基础设施监控系统完备程度;b)服务商数据中心及园区闭路电视监控系统完备程度。.1.6ꢀ综合布线系统综合布线系统运营保障能力评价指标是数据中心内综合布线规范程度。66.2ꢀ运营管理能力.2.1ꢀ信息安全管理信息安全管理能力评价指标包括:a)服务商的信息系统安全管理机制完备程度,包括:123)))信息系统安全风险评价机制;信息系统安全风险识别机制;信息系统安全风险控制目标等管理机制。b)服务商的信息安全管理机制完备程度,包括:1234))))网络流量攻的监控及预警机制;数据中心网络稳定性保障机制;网络攻击行为发现及屏蔽机制;网络敏感信息(涉黄、涉毒、涉赌、反动等)筛查及屏蔽等机制。c)保密机制。6.2.2ꢀ日常管理4YD/T4127-2023设备及资源资产管理能力评价指标包括:a)服务商的资产管理流程及保障机制完备程度,包括:123)))完整的设备资产管理流程;与管理流程配套的ITAM设备资产管理系统;完整的设备生命周期管理机制等流程或管理机制。b)服务商数据中心资产管理措施的落实程度;c)服务商的变更管理措施及机制;d)服务商的容量管理措施及机制。6.2.3ꢀ其他运维管理机制其他运维管理补充机制评价指标包括:a)服务商数据中心应急管理流程及灾难演练机制的完备程度,包括:123)市电中断应急机制;)IT系统容灾方案;有完备的灾难演练机制。)b)服务商数据中心事故处理机制的完备程度。66.3ꢀ网络运营能力.3.1ꢀ网络质量评价网络质量评价指标包括:a)骨干网接入情况;b)网络接入间情况;c)线路冗余情况;d)网络到北上广深等一线城市、西北、西南等大型城市的端到端时延、模拟应用的性能情况。6.3.2ꢀ内部网络互联评价内部网络互联评价指标包括:a)面向数据中心不同用户联通的内部网络建设和管理能力。66.4ꢀ服务品质提供能力.4.1ꢀ服务资质服务资质完备程度评价指标包括:a)服务商企业资质完备程度;b)服务商获取认可程度。6.4.2ꢀ服务产品服务产品完备程度评价指标包括:a)服务商提供基础服务产品及增值服务产品的种类:123)))数据中心空间(机架)、带宽租用服务;主机托管服务;运维外包服务;5YD/T4127-202345)IT设备租赁服务;)网络加速
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 卫生与健康知识竞赛考试试题库及答案
- 西餐服务员培训考题及答案
- 药店工作人员培训试题及答案
- 证券管理考试试题及答案
- 液化石油气库站运行工公司招聘笔试题库及答案
- 职业技能大赛(品酒赛项)理论参考试题库及答案
- 中国妊娠期糖尿病母儿共同管理指南培训考试题及答案
- 中山市渡口渡船安全管理培训考核卷及答案
- 2025年绵阳市实验高中初升高自主招生考试数学试题库(附含参考答案)
- 证券从业资格考试《证券基础》试卷及答案
- 2026年秋季学期“1530”安全教育记录表1
- 2025年青春期矮身材儿童身高改善的药物治疗
- 2026年金川集团招聘试题及答案
- 2025年中秋国庆假期水上交通安全生产方案范文
- 塔吊吊装作业一会三卡样表(安全生产班前会、作业要点卡、风险提示卡、应急处置卡)
- 薪资管理系统初始化设置
- 科大讯飞智慧教育产品的个性化学习解决方案
- 高三日语复习4:高考日语自他动词
- HG+20231-2014化学工业建设项目试车规范
- 众神的山川山海经与上古地理、历史及神话的重建
- 基坑支护旋挖灌注桩技术交底
评论
0/150
提交评论