地库区域停工钢筋保护方案_第1页
地库区域停工钢筋保护方案_第2页
地库区域停工钢筋保护方案_第3页
地库区域停工钢筋保护方案_第4页
地库区域停工钢筋保护方案_第5页
已阅读5页,还剩11页未读, 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

地库区域停工钢筋保护方案目录1、编制目的及适用范围··································································22、编制依据·············································································23、停工工程概况·······································································24、停工部署············································································34.1、停工安排···········································································34.2、停工期间主要工作内容·······························································35、停工具体工作安排及做法·······························································35.1、现场清理·········································································35.2、成品保护·········································································4(1)、钢筋··············································································4(2)、地库区域的降水····································································4(3)、后浇带部位保护···································································6(4)、F区、G区原土保护··································································105.3、主要材料机械设备退场······························································10(1)、周转材料·········································································10(2)、钢筋加工设备及木工设备···························································115.4、人员退场··········································································116、施工组织设计········································································117、项目正常运转保障措施································································117.1、人员组织保障····································································117.2、进度质量保障····································································127.3、安全文明施工保障·································································121.编制目的及适用范围根据2015年10月19日甲方下发的指令单编号-003,具体内容为:请贵司暂停苏州绿地中央广场3#地块3#楼办公楼的施工,具体复工日期待我司复工指令单为准。我司在收到指令单—003后根据图纸及现场时间情况分析以联系单编号-022回复,地库范围包括3#楼地下室一层、二层,3#楼暂停施工直接影响未完成地库F区、G区施工(F区、G区是3#楼出土唯一运输路线)同时也将影响地库的全面结顶时间及后序工序的施工,最为直接的是F区、G区周围已完成区域的临边维护、后浇带全面封闭及外露钢筋保护工作。为保证施工现场相应区域按照业主要求停工,组织相关人员、材料及设备有序退场,特制定本方案。本方案仅适用于浙江港海建设集团有限公司承建的苏州绿地中央广场3#地块项目停工后相关准备工作及措施。2.编制依据1)、本工程施工图纸2)、2015年10月19日建设单位下发指令单编号0033.停工工程概况本工程为苏州绿地中央广场3#地块项目,工程位苏州市科技城龙山路与科发路交叉口。本工程为高层住宅(包括1#、2#、3#、6#、7#楼)及地下车库(后附地库区域图)等工程。结构形式为剪力墙结构,基础采用筏板基础,剪力墙结构抗震等级为三级。其中停工工程概括:楼号建筑面积(m²)建筑层数停工部位钢筋保护直径3#楼65063.3m²-2/36基础8、10、12、14、16、18、20、22、25F区3760m²-2基础G区5594m²-2基础4.停工部署4.1停工安排为了正确引导本工程3#楼、F区、G区越有序退场,合理组织退场顺序。根据我司劳务安排情况,计划在2015年10月20起开始组织退场,各施工队在退场前将停工区域四周外漏钢筋做好防锈处理、地下室楼层临边洞口的防护工作、现场的成品保护、室内垃圾清理、结构修补等工作完成后,经总包和甲方、监理三方确认后方可全面退场。并做好完整的记录手续。4.2停工期间主要工作内容序号主要分项施工内容备注1现场清理模板支撑拆除、清理;地下室内防护及临边维护;悬挂警示标语;停工前期现场清理2成品保护作业层上外露墙柱钢筋防锈;地下室集水坑抽水;地下室后浇带钢管支撑;F区、G区基础四周明水引导排除;3材料设备退场周转材料(钢管、木方、模板)退场;钢筋加工设备退场;电缆、配电柜、配电箱退场;生活区床架退场;4人员退场部分施工人员退场5其他临时设施闲置;5.停工具体工作安排及做法5.1现场清理(1)地库已完成区域待混凝土强度达到拆模条件后,将模板支撑架全部拆除,拆除施工具体内容详见《模板工程施工方案》。(2)模板拆除后将模板、木方、钢管用塔吊及人工配合运至地面或车库顶板,分类码放后,部分分类分批次退场。(3)靠F区、G区临边洞口以及楼梯边的安全防护,搭设三道横杆(楼梯两道横杆),临边洞口端部采用在剪力墙、墙柱植Φ14螺纹钢筋环的方式固定钢管,横杆距地分别为200mm、600mm、1200mm,下设踢脚板,刷红白相间油漆并悬挂好安全警示标志。(4)集水井处上部用木方@200mm作横杆铺设并铺设模板,模板一处预留200*200mm小洞必要时放入水泵抽水。(5)后浇带防护做法为:在后浇带两侧端部延长边顺直方向钉设木枋,木枋立方,上部用多层板钉牢防护封闭,刷红白相间油漆。(6)待楼内清理及防护工作完成后,进行外防护脚手架以及安全通道的拆除,并对B区外侧进行土方回填,架体拆除后,分批次退场。(7)出入口及隔离防护等显著位置悬挂警示标语。5.2成品保护(1)钢筋由于复工时间未明确,作业层上外露墙柱、基础、后浇带钢筋需要进行防锈处理,项目部计划采用刷素水泥浆,外裹2层塑料布,并用透明宽胶带缠紧。a、对外露墙柱钢筋及后浇带进行处理:外露钢筋采用P032.5R水泥掺108胶配制成素水泥浆(水泥:108胶=2:1),对所有的钢筋进行涂刷。在防护前应对所有的钢筋进行除锈,使其表面洁净;对钢筋顶端的丝牙重新上油、包裹,机械连接接头需套丝保护帽;最后对除完重锈的钢筋重新涂刷素水泥浆(厚度以钢筋螺纹不外露为准),外裹2层防潮塑料薄膜(缠绕时要求相互搭接1/2),并用透明塑料宽胶带将薄膜自下而上全部缠紧(缠绕时要求相互搭接1/5),防止薄膜丧失对水泥浆的保护作用,在对完成区域预留外露钢筋涂刷水泥浆时为施工安全考虑需搭设落地式双排脚手架,延F区、G区与完成区域四周搭设:搭设高度11m,设内外支撑,拉结按地库柱间距设置具体见下附图1:b、对外露基础桩承台钢筋进行处理:承台底部及斜面用P032.5R水泥掺108胶配制成素水泥浆涂刷后再浇筑100mm厚C10细石混凝土进行保护;伸出承台外的钢筋用水泥浆涂刷,外裹2层防潮塑料薄膜(缠绕时要求相互搭接1/2),并用透明塑料宽胶带将薄膜全部缠紧(缠绕时要求相互搭接1/5);隐蔽前要求通知建筑工地组织验收,合格后方可隐蔽。停工期间安排专人每周检查一次,如发现有脱落、锈蚀现象及时修复。如遇下雨天气安排专人检查,以保证底板处不能有积水现象。待复工后对所有钢筋表面水泥胶浆清理干净及承台底部斜面混凝土凿出后,方可进行施工。c、基础后浇带钢筋钢筋进行处理;1、将底板部位后浇带的积水抽干,并将后浇带的建筑垃圾等清理干净;2、钢筋清理:将外漏钢筋表面的锈蚀部分和杂质清理干净,如存在胀筋现象应首先将破损的混凝土凿除干净,钢筋表面清理应做到使钢筋露出金属本色,然后用漆刷除去灰尘;3、混凝土清理:对钢筋锈蚀区域的混凝土表面进行清洁处理,用钢丝刷或磨光机将混凝土表面的杂质等清理干净,确保混凝土表面无尘、无脏物、无油脂、无涂料、并保持干燥;4、再用P032.5R水泥掺108胶配制成素水泥浆均匀涂刷,在后浇带两侧端部延长边顺直方向钉设木枋,木枋立放,上部用多层板钉牢防护封闭,刷红白相间油漆防止垃圾进入后浇带确保地下渗水缓慢流出至排水沟并及时排出(具体排水走向见浇带区域图)确保后浇带内无积水;d、涂刷水泥浆时应注意的问题:1、水泥胶浆配比准确,胶量太多则钢筋上表面产生下坠现象严重,致使上表面胶灰太薄。胶量太小则造成与钢筋粘接不好,不能与空气完全隔离,钢筋仍会产生锈蚀。2、后浇带底部钢筋下表面漏刷,刷涂胶浆时要确定先刷涂底部钢筋,再刷涂上部钢筋,钢筋下表面要专门进行一次刷涂。3、施工时注意不可随意弯折钢筋,防止由于弯折钢筋造成质量隐患。(2)、地库区域的降水:按原地库区域管井布置点位置继续降水,待复工后结构达到设计要求后方可停止降水;(3)、后浇带部位保护:1、后浇带两侧铺设木方,木方上覆盖多层板,木方外侧抹防水砂浆,防止上部雨水及垃圾进入后浇带而腐蚀钢筋,减少日后对后浇带处垃圾清理的难度。2、后浇带两侧梁板支撑,在后浇带砼浇筑之前,该跨梁板的底模及支撑均不得拆除。3、延后浇带端部重新用钢管支撑加固,加固时间待地库全面结顶后浇带全部封闭为止(支撑附图见下图1、2);(4)、F区、G区原土保护:本项目部从2方面考虑:最终由建设决定使用何种方案或有第三种方案;a、从经济性上考虑只设置靠原土处砌筑370mm挡土墙,挡土墙在浇筑排水沟后砌筑,具体节点见上1-1剖面土;b、边坡设置简易土钉墙,坑顶地面浇筑100厚C15混凝土确保原土部流失具体如下:(1)在现有边坡上用200型挖机对边坡的原土进行压实,在用人工及时修整,尽量保持边坡壁面的粗糙,以提高喷射混凝土的粘结力。(2)打入锚杆:杆体采用三级螺纹钢直径16长度1.5mm左右@2000*2000;(3)编制钢筋网:钢筋网采用双向φ6.5@300*300,编制钢筋网时,竖筋与横筋之间用扎丝绑扎固定,土定头与加强筋相焊接,加强筋用φ10三级钢;(4)双向加强筋φ10与土钉头连接时如长度不够与土钉头连接时,采用单面焊10d的焊接长度连接;(5)喷射混凝土:土钉施工结束,网片钢筋绑扎后,请监理验收合格后喷射混凝土,喷射混凝土采用强度C20的配合比(水泥:米砂:黄砂=1:2:2)喷射混凝土厚度80mm;(6)如遇下雨天气,基坑坑壁暴露或喷射砼强度不足时,应用彩条布覆盖,防止雨琳后影响坑壁及喷射砼质量;(7)待喷射砼达到强度后再在坑壁顶地面浇筑100厚C15混凝土;(8)基坑施工结束后坑顶地面严禁堆放任何材料;5.3主要材料、机械设备退场(1)周转材料根据本工程特点,1#、2#、6#、7#高层结构地上周转架料为二层满配,地库J区、I区、H区、E区架料为地下二层满配现F区、G区、C区暂停施工,复工时间未定,地库模板、木枋、钢管等周转材料将部分将分类分批次退还及现场堆码整齐,除后浇带位置支撑用钢管架外(后浇带支撑架体方式详见上附图);钢管、扣件利用塔吊人工配合运至地面/地库顶分类整理后请监理确认后公司材料科联系,安排车辆,人工配合塔吊吊装将钢管、扣件退回各租赁制全部归还,复工后重新进场;模板、方木将在地下1层堆码安放,待复工后继续使用如停工时间过长导致此模板、方木无法使用时此模板、方木将作签证。(2)钢筋加工设备及木工设备6#楼钢筋加工场地拆除设备退场,加工设备退场明细如下:序号设备名称数量退场时间备注1钢筋调直机1台2015年10月30日退场2钢筋弯曲机1台2015年10月30日退场3钢筋套丝机3台2015年10月30日退场4钢筋切断机1台2015年10月30日退场5电锯7台2015年10月30日退场地库区域内的临时电源拆除剩一路电源供抽水用。5.4人员退场(1)工人退场本次停工的地库区域及3#楼共涉及2个劳务分包队伍,分别为王敦胜钢筋班组35人,陈柏江木工班组60人,由项目部负责对分包单位进行针对现场相关楼号施工的解释工作,项目部待现场材料清理、安全防护、等工作全部落实完成后,经业主确认,对停工的对地库已施工完成的工程量人工费进行结算付款,并统一向退场劳务工人及劳务管理人员发放停工赔偿金及返程食宿路费,由项目部协助班组责人组织工人统一购买返程车票退场。6.施工组织设计由于工程复工时间未定,工程总进度计划需根据业主要求进一步调整;地库区域及3#楼复工后,涉及的劳务、材料、设备的重新招标进场时间届时需要业主给予明确指令,相关文件内容的修改待复工前30天进行上报。7.项目正常运转保障措施7.1人员组织保障项目部以李银锋经理为首,项目管理人员均不做调动调整,保障项目管理团队的完整性和整体性。7.2进度质量保障项目部根据调整施工部署后,将技术力量和管理精力合理集中,严格遵守业主对其余施工楼栋的施工进度计划要求,严格执行现行国家及地方标准,坚持“三检制”贯彻落实,规范质量验收程序。项目内部每周召开生产质量会,落实一周的生产质量问题。7.3安全文明施工保障项目部坚持执行各项安全检查规章制度,做好工人三级教育和项目领导带班制度,进行定期周安全检查和不定期的日安全检查,对发现的安全问题和安全隐患及时整改落实,并形成检查整改记录,做到有整改,有回复。局部停工区域及施工区域坚持全面做好现场文明施工,各条硬化道路及车库顶板安排3名工人每天清扫,保持主干道清洁;必要时安排一辆洒水车在现场主干道路每天洒水一次。钢柱垂直度的校正采用两台纬仪分别置于相互垂直的轴线控制线上(借用1m线),精确对整后,后视前方的同一轴线控制线,并固定照准部,然后纵转望远镜,照准钢柱头上的标尺并读数,与设计控制值相比后,判断校正方向并指挥吊装人员对钢柱进行校正,直到两个正交方向上均校正到正确位置。根据幕墙施工需要,单纯在关键层打水还不足以确定竖龙骨的定位,为了保证竖龙骨安装的误差在规定范围,在放线时还需要寻找一个辅助层打水以保证两点形成一根定位线,辅助层可以是一个或几个,视实际情况而定,一般情况下随楼层的层高而定,层数越多辅助层就越多,反之亦然。钢柱垂直度的校正采用两台纬仪分别置于相互垂直的轴线控制线上(借用1m线),精确对整后,后视前方的同一轴线控制线,并固定照准部,然后纵转望远镜,照准钢柱头上的标尺并读数,与设计控制值相比后,判断校正方向并指挥吊装人员对钢柱进行校正,直到两个正交方向上均校正到正确位置。根据幕墙施工需要,单纯在关键层打水还不足以确定竖龙骨的定位,为了保证竖龙骨安装的误差在规定范围,在放线时还需要寻找一个辅助层打水以保证两点形成一根定位线,辅助层可以是一个或几个,视实际情况而定,一般情况下随楼层的层高而定,层数越多辅助层就越多,反之亦然。负责每周的全员安全生产例,定期不定期组织安全生产文明施工的检查,加强安全监督管理、消除施工现场安全隐患。负责安全应急预案的编制,进行安全应急演练,保证施工生产的正常进行。负责对各专业分包单位(劳务分包)的安全监督管理工作,督促专业分包单位作好安全防护工作,消除施工过程的安全隐患,确保安全生产。专业施工员是施工技术、进度、质量的主要负责人,建立以专业施工点为主的计划执行系与施工员为主的计划检查系这一对立统一的工作关系,是保证进度计划的重要方法。施工员每日进行现场检查,并将检查的结果每日以书面的形式汇报理,以便及时了解施工动态,监督督促各施工班组按计划完成工作,及时进行必要的调整。综合训练馆钢结构分门球场钢结构雨篷钢结构两部分。综合馆屋盖为空间螺栓球网架结构体系,网架高度2.0m,钢管材质为Q235B高频焊管或无缝焊管,钢结构网架支座位于混凝土结构柱柱顶,网架支座为上弦节点支承板橡胶支座,结构纵向跨度50.7m,横向跨度36.9m,总用钢重约25t。钢柱柱底就位柱底标高校正完成后,即可用纬仪检查垂直度。方法是在柱身相互垂直的两个方向用纬仪照准钢柱柱顶处侧面心点,然后比较该心点的投影点与柱底处该点所对应柱侧面心点的差值,即为钢柱此方向垂直度的偏差值。其值应不大于H/1000且绝对偏差≤±10mm,当视线不通时,可将仪器偏离其所在的轴线,但偏离的角度应不大于15度。钢柱吊点的设置需考虑吊装简便,稳定可靠,故直接用钢柱上的连接耳板作为吊点,每节钢柱共四个吊点。为穿卡环方便,在深化设计时将连接耳板最上的一个螺栓孔的孔径加大,作为吊装孔。为了保证吊装衡,挂设四根足够强度的单绳进行吊运;为防止钢柱起吊时在地面拖拉造成地面钢柱损伤,钢柱下方应垫好枕木。根据现场实际调查及以上排列图分析显示,“气孔”出现缺陷的频率为84.4%,如果能将此两项出现的质量问题完全杜绝,焊接一次合格率能达到84.4%+(1-84.4%)×64.1%≈94.4%,但考虑到一些不可预见的因素对解决问题造成的影响,我们决定将这个主要问题解决到80%以上,那么我们确定目标焊接一次合格率为84.4%+(1-84.4%)×64.1%×80%=92.3%。施工前,根据工程任务的要求,收集好规划、勘察、设计及施工等有关资料;业主提供的城市坐标控制点;岩土工程勘察;施工设计图纸;了解设计意图,熟悉校核图纸。对于建筑工程测量,了解建筑总体布局、建筑定位依据建筑定位条件。另外要校核图纸尺寸,检查建筑柱列轴线等结构部件尺寸是否有矛盾的地方,对一些特殊要求,包括预埋件、预留孔等位置精度,要加注说明。由西南侧环形通道进入膜结构内部进行吊装作业,结构安装完成后吊机沿环形通道原路退出。因本工程顶部扇形姿态异型悬挑构件悬挑跨度达到8.2m,安装高度达到19.200m,现场安装时需借助临时支撑措施辅助安装,临时支撑措施采用格构式圆管胎架。为确保安装过程的整体结构稳定性安装精度,现场安装按照先主后次、对称施工的原则进行,主体结构安装完成后进行拉索的安装及预应力张拉作业,整体结构形成稳定体系后拆除临时支撑措施。后补杆件吊装就位时,设置纬仪于与其相连接的两节点的纵向方向线上,监测已安装单元顶的空间位移,必要时需对杆件垂直度用水准仪测量桁架面标高,通过千斤顶、楔铁等工具作适当的调整,实现桁架直线度扭曲在规范要求内,以确保整体的安装质量符合设计及相关规范要求。分台阶挖土时,上下二个台阶的间距不能小于8米,也不宜大于12米,因为小于8米就失去了台阶的作用,落差过大,土压力释放过大,造成支护挤压力过大。间距大于12米,则挖土面无法相互传递。台阶的边坡要在1:2以下(具体放坡坡度根据不同土性确定),防止坑内土方滑移而影响支撑桩。根据设计图纸要求坐标、标高,预留槽洞或预埋套管。采用支、吊、托支架时,应按设计要求的坐标、标高及坡向作好支架。UPVC塑料排水管横管上支架设置必须符合下表规定,且支架间距均匀,布置美观。干管施工条件具备时,将预制加工的管段,按编号运至安装部位,各管段粘连时,必须按粘连工艺依次进行。全部粘连后管道要直且坡度均匀,各预留口位置准确,最后把各预留口封严,以防杂物掉入管内而堵管。随着建筑结构领域科学技术的展,大跨度建筑结构大量应用。大型钢结构屋盖结构的建筑不断涌现,为满足建筑内部大空间的需求,多有屋盖下多层楼面采用钢吊挂层结构,结构传力路径不同于普通结构,因此传统自上而下安装顺序不再适用。本工法迎合上述建筑结构施工的需要,适用于大型全钢结构桁架屋盖及下设多层钢结构吊挂层的安装施工,实现此类结构的精确安装安全施工。本工法已成功应用于天津文化心大剧院工程生态城动漫大厦钢通廊工程的施工。理部物资设备部在进行材料采购时,先向甲方递交样品,甲方审核认可后,理部根据施工进度计划进行加工订货,翻样单上注明加工尺寸、规格、数量、材料名称、材质质量要求及进场日期。材料验收采取三方联合验收方式,即甲方、监理、施工单位三方联合验收,并填写各种相关表格相关资料(材料报验单、合格证、检测等)报批准后再使用该材料。工程质量的好坏,进度的保证很大程度上与施工机具的先进性有关。对于本工程的施工,我公司针对本工程的实际情况各工种、工序的需要,合理地配备先进的机具设备及挑选专业水较高的技术操作人员,最大限度地体现技术的先进性机具设备的适用性,充分满足施工工艺的需要,从而保证工程质量装饰效果。我司安排有专门材料采购人员负责本工程的材料采购,我司大型钢厂均有良好的合作关系,可以保证材料的及时供应,比一般市场采购进货时间可以提前15天左右。结合我单位材料采购验,能够保证工期进度安排的要求。同时我司拥有充足的库存钢板从整个工程施工进度安排分析,各个分部工程的施工时间都进行了充分的考虑,并做到稍有富余。在工程实际施工管理,只要部严格按照施工总进度计划的要求,并编制详细的分部分项工程作业计划及月旬作业计划,在保证工程质量的基础上,施工工期以抢为主,如期完成该工程是完全可行的。考虑在地下室底板及墙板完成后,对北侧入口采用回填矿渣铺设一条6m宽的1:4的坡道,上铺路基板,250T汽车吊此入口进入地下室底板上进行上部主钢梁、钢柱的吊装。待主钢梁、钢柱吊装完成后,再进行地下室顶板的浇筑。QTZ315塔吊安装在工程6-7轴×E-F轴间位置,作为钢结构主、次檩条吊装之用。事故应急指挥部下设专业组:技术组、工程组、医疗救护组、通迅组、警戒组。技术组,由施工人员组成,负责查明事故真相,提出事故处理方案并参加处理;工程组由施工人员组成,配备必要机械设备、消防灭火器具、负责排爆灭火、抢险救灾、消除事故影响,恢复正常生活;医疗组由医护人员组成,配备救护车、医疗器械设备,负责抢救伤员;警戒组由警卫人员组成,配备通讯器材,负责现场警戒;通讯组由通讯人员组成,配备通讯器材,负责沟通信息联系。场地位置交通便利,北侧为现状钱江路,目前正在进行地铁9号线建设,本用地红线距离9号线隧道结构边线最近距离约为6m;往西80m为京杭运河,其西南角为现状四堡污水处理站;南侧与钱塘江隔之江东路相邻;东侧现状为铁隧道局施工场地(地铁6号线),距离地铁6号线区间隧道的最小距离约15m。考虑到本结构高度到99.550米,地下5层,地上21层,而激光铅直仪有效施测距离有限,同时为提高点位捕捉精度,应减少控制轴线垂直引测的接力次数,需要对控制网阶段性传递做一个整体性规划。故选择地下-5层、5层、15层作为控制网阶段性传递层,以分别控制-5~5层、5~15层、15~顶层共设3个循环。允许的水范围。必须确保砼特别是钢筋不因过量或疏忽使用脱模剂而造成污染。墙的部门洞开口处模板应用木条定位在混凝土板上,墙模板需要用穿线保持直线并且用木板定位在混凝土地板以挤紧其底部;进行这些操作时,也需要用铅垂检查门洞开口部的垂直度,如有可能,门洞处安装定位工具。支座的养护维修:滑动支座由钢材、不锈钢、聚四氟乙烯(填充聚四氟乙烯、改性超高分子量聚乙烯)、润滑脂等多种材料组成。钢材外露部位采用热镀锌或喷漆防锈处理,在室内能正常使用50年,不锈钢、聚四氟乙烯(填充聚四氟乙烯、改性超高分子量聚乙烯),能满足50年的使用要求。箱体U型组立时,首先将隔板与下面板组装,组装时必须保证隔板的垂直度以及电渣焊衬垫板与下面板的间隙(当隔板间距较窄时,为了便于后续焊接,应将焊接坡口朝外。当隔板较密集时,应从间向两侧逐步退装退焊,即先装间两块隔板,装好后即行焊接,然后依次向两侧装焊)。合格后点焊固定。U型组立时为了提高柱子的刚性及抗扭能力,在部分焊透的区域每1.5mm处设置一块工艺隔板。隔板定位合格后,组装箱体腹板,组装时将腹板与翼缘板下对齐,并用千斤顶夹具将腹板与下翼缘板隔板顶紧靠牢。腹板定位合格后安装腹板与面板全熔透焊缝的焊接衬垫板。箱体U型组立后交专人检测,合格后进行隔板腹板的焊接,隔板与腹板焊接坡口形式为单面V形坡口,焊接采用CO2气体保护焊进行,焊后对焊缝进行探伤检测。在施工人员选择上,我们将采用施工验丰富的施工人员进行安装,并选派具有丰富工程管理验的理负责现场的组织、协调管理,保证达到科学施工、有序施工。班子有多年合作验,人员相互了解、分工明确,对工程的重点难点,把握准确,质量的控制点清晰,更有利于现场的施工工期及施工质量得到有效的保证。模板的安装必须保证位置准确,立面垂直,安装完成后再用靠尺对模板垂直度进行复验,现不垂直时,可通过模板下部的地脚螺栓进行调整;模板安装接缝部位必须严密,防止漏浆,同时应处理好各个节点及阴阳角部位的构造;其底部有缝隙时,要用砂浆或者木条塞严,但不可将塞缝物塞入墙体内,以免影响墙体的断面尺寸。连廊钢梁主要采用STT553塔吊进行吊装,在吊装过程须做临时固定措施,但其下部无结构,无法做胎架支撑,拟采用在连廊上层混凝土梁或混凝土柱上预埋埋件,在埋件较短段主梁上焊接吊耳,用手拉葫芦对一分段进行临时固定,继而用同样的方法完成另一部的分段安装,最后利用塔吊及马板安装间分段及其他钢梁、花纹钢板等。施工操作注重工序的优化、工艺的改进工序的标准操作,在每项工作开始之前,首先进行样板施工,在样板施工严格执行既定的施工方案,在样板施工过程跟踪检查方案的执行情况,考核其是否具有可操作性及针对性,对照成品质量,总结既定施工方案的应用效果,并根据实际情况、施工图纸、实际条件(现场条件、操作队伍的素质、质量目标、工期进度等),预见施工将要生的问题,完善施工方案。ZSL750塔机首次采用固定式基础的内爬塔机,随着工程的进度,当塔机最大独立高度工况无法满足使用要求后,需要及时转换成爬升工况。塔机转内爬工况前,首先要根据整个施工规划预先将塔机支撑系统的预埋件埋入建筑物墙体(核心筒)上,安装上下两道支撑梁内爬支撑框方可进行爬升。首先将十字型分成一个H型两个T型,待H型T型分别组装焊接并检测合格后再进行十字型组装焊接。对两个T型组装焊接时为了有效控制组装焊接变形,并充分利用机械化作业提高加工效率,将两个T型通过加固连接措施组拼成“H”型,待“H”型组装焊接合格后将其拆分成两个T型。混凝土振捣:墙混凝土采用HZ-50型插入式振捣棒振捣,结点部位空隙较小处,可采用HZ6X-30型插入式振捣棒振捣。下料过程,应严格按照500mm一道分层下料,300mm以上墙体应在墙体内两侧距钢筋50mm处振捣,移动间距不得大于500mm,插入深度应进入下层混凝土50mm,振捣时应快插慢拔,插入10S左右开始慢慢提棒,直至气泡全部排完并翻浆,严禁快插快拔或插入棒后超时间振捣。每层混凝土浇筑完后约15min左右再浇筑下一层混凝土。即首先将整个作为一个整体进行施工部署,然后将钢结构与外幕墙分为2个相对独立的分项,在人员组织、施工机械投入、材料采购、加工制作、施工方案以及施工安全措施、质量保证措施上进行相对独立的考虑及安排,在工期安排上,为保证这个在工期要求内完成封闭及竣工验收,钢结构与外幕墙将采取搭接流水作业施工。本方案针对武汉绿地心副楼钢走廊、转换桁架及钢屋盖施工内容而制定。目的在于保证副楼钢走廊、转换桁架及钢屋盖的顺利施工,施工工序、工艺流程的各个环节在的施工全过程始终处于受控状态,检查监督等方面都有章可循、有序运作,在安全生产、质量管理、工期进度等方面有明确的目标、要求合理的措施、保证高质量、高标准、高速度的要求。理协调内部人与人,各部门之间的工作关系,充分调动每个人的工作热情,使得人尽其才,用人之长,责任分明,使部精干、高效、政令畅通。由理进行内部供求关系的协调,诸如劳动力、材料、机械设备、动力等,求得的资源保证,从而使物尽其用,按施工进度计划进行有条不紊的施工。若检查的实际施工进度产生的偏差影响了总工期,在工作之间的逻辑关系允许改变及征得业主、监理工程师同意的条件下,改变关键线路超过计划工期的非关键线路上的有关工作之间的逻辑关系,或加大投入、缩短影响进度的工作时间,达到缩短工期的目的,并在确保工期及业主、监理工程师同意的基础上,重编制实施进度计划。为使本围护支撑体系均匀对称受力,开挖土方必须对称开挖,先外围后心。先用挖机在支撑梁上面把整个支撑梁内的土方掏挖出来,使支撑梁对称且缓慢受力。然后以人工到下面挖出支撑梁下面挖机不能挖到的土方,慢慢使整个支撑梁全部受力。防止改变支撑体系的设计受力工况,造成支撑梁损坏。为了保证楼层桁架结构在安装过程的稳定,同时保证结构由施工状态缓慢过度到设计状态,结构在拆除支撑后,保证桁架通过内、外支座的稳定的受力,与设计初始位置相吻合,此间,桁架结构生较大的内力重分布,并逐渐过渡到设计状态,因此,支撑架拆除工作至关重要,必须针对结构支承情况,确定合理的拆除顺序。工具化附着式升降脚手架爬升过程葫芦链条断裂,造成提升停止,由于机位本身具有可靠的防坠落装置,同时在每个机位设

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论