VACONCabinet

VACONSuzhouDrivesCo.,Ltd11.NXC-CompactandFlexibleSingleDrive2.NXC-LowHarmonic3.NXC-cabinetoptions4.Liquidcooledcabinets5.Custombuilt

VACONSuzhouDrivesCo.,Ltd2NXC-CompactandFlexibleSingleDrive

2.NXC-LowHarmonicSingleDrive3.NXC-Cabinetoptions4.Liquidcooledcabinets5.CustombulitContentsNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd3Size400Vsupplyupto690VsupplyuptoFR9160kW200kWFR10250kW400kWFR11400kW560kWFR12560kW800kWFR13800kW1150kWFR141200kW2023kWVaconNXC-ProductRangeSingleDriveUnitsFR9-FR14:Voltagerange:380-500,500-690VPowerrange:110kW–2023kWEnclosureclasses:IP21orIP54Supply:6-pulseor12-pulseFR10FR11FR12FR13FR14FR9*DriveSynchcontrolconceptforhigherpowersNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd4CabinettypecodeselectionviaVST1,productselction-NXCcabinet2,Frequencyconverter–FCbasic3,optionscardsselection4,cabinetoptionsselectionNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd5Frame400v/690v6PInnerbrakechopper12PInnerbrakechopperFR9FR10FR11FR12FR13

FR14

Brakechopperunitneededwith+MDCoptionNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd66Example:NXC05205A2L0SSFA1A20000C3

+IFD+TIO+ODUEasilyaccesiblecontrolcompartmentforrelays,terminalsandotherequipmentNXPpowerunitonrailsforeasypull-outwithoptionalpull-outjigKeypadindooranddooroptions:indicators,meters,switchesBasicFCmoduleControlcompartmentOutputterminalsInputdeviceoptionsInputchokeOutputfilteroptionNXCConstruction

VACONSuzhouDrivesCo.,Ltd77MMMFR9-10SingleInputSingelOutputFR11DoubleInputSingelOutput**notinNXP04606andNXP05026W=600mmW=800mmIP21H=2275mmIP54H=2405mmD=605mmW=600+600mmFR12DoubleInputDoubleOutput**12-pulsesupplypossibleforFR10NXC-CompactandFlexibleSingleDriveNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd8FR14SingleInputSingelOutputFR14SingleInputSingelOutputFR13SingleInputSingelOutputMINUNFENFENFEINUNFENFEINUNFENFEMINUNFENFEINUNFE*FR13unitsNXP1300andNXP1450havethreeNFEunits.*IP21H=2275mmIP54H=2445mmD=605mmW=2800mmW=1400mm(OnlyNXC150066-pulsesupply)MNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd9Cooling forcedair-cooledbydrivemodule’sfanEnclosure RittalTS8Degreeofprotection IP21orIP54(EN60529:1992/A1:2023Ambienttemperature -10...40C(35framesizehighestcurrentin690V),upto50Cwithderating(1,5%per1C)Storagetemperature -40C…70°CRelativehumidity 0to95%RH,non-condensing,non-corrosive,nodrippingwater

Altitude100%loadcapacity upto1000mwithoutderatingMaterial tinnedcopperRatedconditionalshort-circuit Icc/Icf50kA(500V),Icc/Icf40kA(690V) PEbusbarconnectedtochassis

Colorshade RAL7035Miscellaneous: touchprotectionwithdoorsopen dooropeningangle130°,canberetrofittedto180° onrequestMarkingwires equipmentpinnumberequipment devicetagPackaging plasticfoilrappingandwoodenframe transportationbreakspossibleonrequest seaworthypackagingoptional(+SWP)Vibration 5…150HzEN50178/EN60068-2-6, displacementamplitude0.25mm(peak)at5-31Hzmax.accelerationamplitude1Gat31…150HzShock UPSDropTest(forapplicableUPSweights)EN50178,EN60068-2-27 storageandshipping:max15G,11ms(inpackage)Standards EN60439-1,EN61800-5-1,EN61800-3,EN50178/ EN60068-2-6

TechnicaldescriptionNXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd10Mainsvoltage,UN 380-500V,3~,+10%...-10%,500-690V,3~,+10%...-10%,TN-S,ITSupply 6-or12-pulseInputfrequency 45…66HzOutputfrequency 0-320Hz,7200HzwithHSapplication,ifdudt,checkwithproductmanagerSwitchingfrequency 1-6kHz(380-500V),default3,6kHz,1-6kHz(500-690V),default1,5kHzEfficiency ~98%(atnominalpower)Aux.voltagedistribution 230Vac1~(miniaturecircuitbreakerprotected)Control frequencycontrolU/f,openloopsensorlessvectorcontrol,closedloopvectorAltitude 100%loadcapacityupto1000m,1%deratingforeach100mabove1000m,Safetorqueoff(STO)optional(OPT-AFboard)Emergencystopcircuit optional(+PES/PED)EMC categoryC3(EN61800-3),categoryC4(EN61800-3)forIT-networksStandardsIECClassification CE,ULElectricalcharacteristicsOpenloop:-Speederrorinsteadystatetypically<0.5%-Torquerisetime<10ms-Torqueerrorinsteadystatetypically<3%-SuitablealsoformultimotorconfigurationCloseloop-Speederrorinsteadystatetypically<0.01%(pulseencodertypedependent)-Pulseencoder:250…5000pprat5,12or24V(optionboarddependent)-Torquerisetime<10ms-Torqueerrorinsteadystatetypically<3%NXC-CompactandFlexibleSingleDriveVACONSuzhouDrivesCo.,Ltd11Thefollowingisincludedbydefault:

Connectorsformainsandmotorconnections(FR9-FR12)Busbarsformainsandmotorconnections(FR13-FR14)ACchokes

ACfusesand+ILS-loadswitch(onlyFR13/FR14)DCfuses(onlyFR12withbrakechopperor12-pulse,andFR13/FR14)Cablingfrombottom(fromtopoptional,+CIT/COT)Frequencyconverter(refertocabinetthespecificdocumentation)Doormountedkeypad

VACONSuzhouDrivesCo.,Ltd12NXC-CompactandFlexibleSingleDrive

2.NXC-LowHarmonicSingleDrive3.NXC-Cabinetoptions4.Liquidcooledcabinets5.CustombulitContentsNXC-LowHarmonicSingleDriveVACONSuzhouDrivesCo.,Ltd13Size400Vsupplyupto690VsupplyuptoAF9160kW200kWAF10250kW400kWAF12560kW800kWAF13800kW1150kWAF141500kW2023kWSingleDriveUnitsincl.LCLfilter(s),chargingcircuitry,AFE&INUunit(s)Voltagerange:380-690VPowerrange:132kW–2023kWEnclosureclasses:IP21orIP54Supply:ActiveFrontEndInputdevices:LoadSwitch+MCCBNXCAF9-10,IP21NXC-LowHarmonicSingleDriveVACONSuzhouDrivesCo.,Ltd14Size400Vsupplyupto690VsupplyuptoAF9160kW200kWAF10250kW400kWAF12560kW800kWAF13800kW1150kWAF141500kW2023kWSingleDriveUnitsincl.LCLfilter(s),chargingcircuitry,AFE&INUunit(s)Voltagerange:380-500V/525-690VPowerrange:132kW–2023kWEnclosureclasses:IP21orIP54Supply:ActiveFrontEnd*DriveSynchcontrolconceptforhigherpowers14

-1.0-0.50.00.51.0YYDM~=Currentdistorition(THDi)>12%12-pulserectifierwithchokesExpensivetransformerandpowercablingwithlowcurrentdistortion.

-1.0-0.50.00.51.0~M~=~=YYCurrentdistorition(THDi)<5%Low-HarmonicdriveCosteffectivetransformerandpowercablingwithverylowcurrentdistortion.Nooversizingoftransformer

-1.0-0.50.00.51.0Currentdistortion(THDi)>35%M~=YY6-pulserectifierwithchokeCosteffectivetransformerandsimplepowercablingwithhighcurrentdistortion.

ReducingtheHarmonicCurrents15Wellequippedalreadyasstandard,including:LoadswitchandMCCBasinputdevicesExternalAC/DCconverter(230VAC/24VDC)Aux.transformerandbasiccontrolterminalsManual/Remote/AutomaticcontrolswitchforMCCBandpre-chargingcircuit0-1-StartSwitchforMCCBandpre-chargingcircuitPilotlightsforAFEREADYindicationandMCCBTRIPindicationMCCBresetpushbutton

MNXCAF9-10SingleInputSingleOutputINUAFEMFNXCAF9-10,IP211006x2275x605NXC-LowHarmonicSingleDrive16InverterunitActivefrontendunitLCL-filterwithDC-DCfansupplyLoadswitchandMCCBasinputdevicesNXC-LowHarmonicSingleDrivePre-chargingcircuitAux.transformerandbasiccontrolterminalsExternalAC/DCconverter(230VAC/24VDC)MotorcableterminalsSupplycableterminalsInverterunitMotorcableterminalsW=2023mmIP21H=2270mmIP54H=2400mmIP21D=605mmW=2023mmIP21H=2275mmIP54H=2405mmD=605mm+ODUW=400mm17NXC-LowHarmonicSingleDriveNXCAF12SingleInputSingleOutputINUAFEMFMINUAFEMF+ODUdu/dt-filter(optional)IP21H=2270mmIP54H=2400mmD=605mmW=2206mmIP21H=2275mmIP54H=2405mmD=605mmW=2206mm18NXC-LowHarmonicSingleDriveMNXCAF13SingleInputSingleOutput(NXCAF14=2xAF13)INUAFEMFNXC-LowHarmonicSingleDriveVACONSuzhouDrivesCo.,Ltd19Cooling forcedair-cooledbydrivemodule’sfanEnclosure RittalTS8Degreeofprotection IP21orIP54(EN60529:1992/A1:2023)

Ambienttemperature -10...40°C(35°framesizehighestcurrentin690V),upto50°Cwithderating(1,5%per1°C)Storagetemperature -40C…70°CRelativehumidity 0to95%RH,non-condensing,non-corrosive,nodrippingwaterAltitude100%loadcapacity upto1000mwithoutderating

MainbusbarstinnedcopperRatedconditionalshort-circuitcurrentIcc/Icf50kA(500V),Icc/Icf40kA(690V) PEbusbarconnectedtochassis

SurfacetreatmentEnclosure nanoceramicpretreatment,anodicdipcoat-primingandtexturedpowder-coatingMainbusbars tincoated8umSheetmetal zinccoated275g/m2 Colorshade RAL7035Miscellaneous: touchprotectionwithdoorsopen,dooropeningangle130°,canberetrofittedto180° onrequest

Markingwires equipmentpinnumberequipment devicetag

Packaging plasticfoilrappingandwoodenframe,transportationbreakspossibleonrequest,seaworthypackagingoptional(+SWP)

Vibration 5…150HzEN50178/EN60068-2-6, displacementamplitude0.25mm(peak)at5-31Hz,max.accelerationamplitude1Gat31…150HzShock UPSDropTest(forapplicableUPSweights)EN50178,EN60068-2-27 storageandshipping:max15G,11ms(inpackage)Standards EN60439-1,EN61800-5-1,EN61800-3,EN50178/ EN60068-2-6TechnicaldescriptionNXC-LowHarmonicSingleDriveVACONSuzhouDrivesCo.,Ltd20Electricalcharacteristics

Mainsvoltage,UN 380-500V,3~,+10%...-10%,525-690V,3~,+10%...-10%,TN-S,IT Supply ActivefrontendInputfrequency 45…66HzOutputfrequency 0-320Hz,7200Hzwithhighspeedapplication,ifdudt,checkwithproductmanagerSwitchingfrequency(INU) 1-6kHz(380-500V),default3,6kHz,1-6kHz(525-690V),default1,5kHz

THDi~5%(nominalconditions)Efficiency 96%(atnominalpower)Aux.voltagedistribution 230Vac1~(miniaturecircuitbreakerprotectedControl frequencycontrolU/f,openloopsensorlessvectorcontrol,closedloopvectorAltitude 100%loadcapacityupto1000m,1%deratingforeach100mabove1000mSafetorqueoff(STO)optional(OPT-AFboard)Emergencystopcircuitoptional(+PES/PED)EMCcategoryC3(EN61800-3),categoryC4(EN61800-3)forIT-networksStandards IECClassificationCE,ULOpenloop:-Speederrorinsteadystatetypically<0.5%-Torquerisetime<10ms-Torqueerrorinsteadystatetypically<3%-SuitablealsoformultimotorconfigurationCloseloop-Speederrorinsteadystatetypically<0.01%(pulseencodertypedependent)-Pulseencoder:250…5000pprat5,12or24V(optionboarddependent)-Torquerisetime<10ms-Torqueerrorinsteadystatetypically<3%NXC-LowHarmonicSingleDriveVACONSuzhouDrivesCo.,Ltd21Thefollowingisincludedbydefault:

busbarsformainsandmotorconnectionsLCLfilter(s)Chargingcircuitryandchargingresistorscablingaccessfrombottom(fromtopoptional,+CIT/COT)frequencyconverter(refertocabinetthespecificdocumentation)ACsupplythroughmoldedcasecircuit-breaker(s)(+ICB+AMO),Loadswitch(+ILS)DCfuses(onlyFi12/Fi13/Fi14units)doormountedcontrolbuttonsforcircuit-breakers(+DCO),doormountedkeypadcontroltransformer230VAC(+ATX)I/Ocontrolconnectionswiredtoexternalterminals(+TIOor+TID)externalterminalsforcontrolvoltage230VAC(+TUP)22WhyNXC-WellDesignedReliableBasedonthewellacceptedandrobustRittalTS8enclosureIP21airgridinroofandairblockingshieldsforgoodthermalperformanceNoadditionalcabinetfansinIP54versionEasyHandlingNospaceneededbehindtheenclosure(canbeinstalledtowardsthewall)InternallyprotectedagainstunintentionaltouchDoormountedkeypadandRS-232intefaceasstandardPre-puncheddoorpreparedforeasyadditionofdoormountedaccessories23WhyNXC-EasyInstallationLiftinglugsforeasyunpackingandhandlingCanbemountedagainstthewallorfreestandingFixingtothefloorbyscrewsinthefrontbottomFixingtothewallbyscrewsinthetoprear.ThefixingbarcanbeslidedhorizontallytomaketheenclosurestandstraightFreestandingenclosurescanbefixedtothefloorinfourlocationsOptional100mmor200mmbaseavailable24WhyNXC-EasyMaintenanceThepowerunitsaremountedonrailsforeasypull-outWiththeoptionalpull-outjigapowerunitcanbefullypulledoutforserviceNoadditionalcoolingfansintheenclosureIP21/IP54ThefansofthepowerunitcanbeeasilyreplacedwithouttakingoutthepowerunitStandardRittalcolourRAL7035usedforeasyoptionandspare-partaccesslocallythroughRittalsalesnetwork25WhyNXC-VaconDocumentationWizard(VDW)fordrawingsNXCtypecodeDownloadlinkUserinterfaceDrawingsWhyNXC-shortleadingtimeVACONSuzhouDrivesCo.,Ltd26

VACONSuzhouDrivesCo.,Ltd27NXC-CompactandFlexibleSingleDrive

2.NXC-LowHarmonicSingleDrive3.NXC-Cabinetoptions4.Liquidcooledcabinets5.CustombulitContentsNXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd28Auxiliaryequipmentoptions(GroupA)+AAA-Auxiliarycontactfor+ATxsupervision,aDINneeded+AAC-Auxiliarycontactfor+Ixxoptions,aDINneeded+AAI-Analoguesignalisolator+ACH-CabinetHeater50W,anauxiliaryvoltagetransformerand+TUPneeded+ACL-Cabinetlight,anauxiliaryvoltagetransformerand+TUPneeded+ACR-Controlrelay,aDOneeded,FR13requiresa+G40(width400mm)oraCIT/COT+ACS-230VACcustomersocket,includesa30mAresidualcurrentcircuitbreaker,anauxiliaryvoltagetransformer/+TUPneeded+ADC-Powersupply24VDC2.5A,anauxiliaryvoltage/+TUPneeded+AMB-Mechanicalbrakecontrol,a4kVA400V3-phaseoutputwithacontactorandamotorcircuit-breakerforprotection,RO/+TUPneeded,FR13alsorequiresa+G40orCIT/COToption+AMF-Motorfancontrol,4kVA400V3-phaseoutputwithacontactorandamotorcircuit-breakerforprotection,,RO/+TUPneeded,FR13alsorequiresa+G40orCIT/COToption+AMH-Motorheaterfeeder,asingle-phaseoutput230V10Awithacontactorandmotorcircuit-breaker,anexternal230V/RO/+TUPneeded+AMO-ICB(Circuitbreaker)motoroperator,anauxiliaryvoltage/+TUPneeded+ATX-Auxiliaryvoltagetransformer,400-690V/230V,+TUPneeded•AT1200VA•AT2750VA(min.sizefor+ICO)•AT32500VA(requires+G40inFR13/14)•AT44000VA(requires+G40inFR10/12/13/14)NXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd29Cablingoptions(GroupC)+CITCablingInputTopThe+CITincludesa+COT(CablingOutputTop).AllVaconNXCdrivesare,bydefault,designedforthepowercablingtoberoutedthroughthebase.Ifcablingistoberoutedthroughthetop,thedrivehastobeequippedwithanextracablingsection,whichisusedtoreroutethecablestothetop.Thecablingsectioncanbeusedforboththesupplyandmo-torcables,i.e.The+CITpricealsoincludesa+COTorviceversa.Itshould,however,alwaysbeindicatedintheorder,ifonlyoneorbothareneeded.Thisoptionincreasesthewidthofthecabinetby400mm(FR10-FR13)or600mm(FR14).NXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd30DoorMountedoptions(GroupD)+DAM-Analoguemeter,wiredtotheAO+DAR-Potentiometertoreference,aAIneeded+DCM-Analoguemeterandcurrenttransformer,.Itusesacurrenttransformertomeasuretheinputcurrentfromoneoftheinputphases.+DCO-MCoperationswitch,0-1start,a+TUPneeded+DEP-Emergencypush-button,a+TUPneeded+DRO-Local/Remoteoperationswitch,aDINneeded+DRP-Resetpushbutton,aDINneeded+DVM-Analoguevoltagemeterandselectorswitch,twosetsneededforall12-PphasesDoorIndicatorLights+DLD-Pilotlight(DO1)“READY”,24VDCandDOneeded+DLF-Pilotlight“FAULT”,230V/RO/+TUPneeded+DLR-Pilotlight“RUN”,230V/RO/+TUPneeded+DLV-Pilotlight“CONTROLVOLTAGE”,230V/+TUPneededNXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd31ExternalTerminals(GroupT)+TIO-TerminalI/O35pcs,locatedonthehigherassemblyplateinfrontofthepowermodule.+TID-TerminalI/ODouble,70terminalsandislocatedonthehigherassemblyplateinfrontofthepowermodule.+TUP-Separateterminalsfor230VACcontrolvoltage,locatedonthehigherassemblyplateinfrontofthepowermodule.ThisoptionisautomaticallyaddedtotheVaconNXCwithoptions+ATx,+ACSand+ADCGeneraloptions(GroupG)+G40,+G60,+G80areemptycabinets(400mm/600mm/800mmwidth)+GPL-100mmhighPlinth+GPH-200mmhighPlinthMainCircuit(GroupM)The+MDCoptionprovidesextraterminalsinthecabinetforconnectingbrakeresistorstothebrakechopper.ThisoptionprovidesaccessforfieldcablingtothebrakechopperinunitsFR9-FR12.The+MDCoptioncanonlybeused,ifthedriveisequippedwithabrakechopper.NXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd32OutputDeviceOptions(GroupO)+OCM-Common-modechokes,reducetheriskofthesebearingcurrents+ODU-du/dtfilter,FR10-12,the+ODUismountedinanadditional400mmcabinet.InframesizesFR9,FR13andFR14thefil-tersdonotrequireanyadditionalcabinet+OSI-SineWavefilterProtectionDevicesoptions(GroupP)+PAP-Arcprotection,Thisoptionrequiresanauxiliaryvoltagetransformer(+ATx)oranexternal230Vsupply.The+PAPalsore-quiresa+TUPoption.+PES-EmergencyStop(Cat0)Theoptionincludesasafetyrelay•category3or4AChighvoltagepush-buttoncircuits•contacts3N/O,1N/C•withinternalauxiliarypowersupplyprotectionwithautomaticreset•singlechannelordualchanneloperation•manualorautomaticreset•cross-faultmonitoringofemergencystoppush-buttoncircuits230V/+TUP.TheFR13requiresa+G40(width400mm)ora+CIT/+COT.Needed+PED-EmergencyStopcircuit(Cat1),+PES+timerelay(0-10s)+PIF-Insulationfaultsensor,230V/+TUPneededNXC-cabinetoptionsVACONSuzhouDrivesCo.,Ltd33InputDevice(GroupI)+ICB-Circuitbreaker(MCCB),Thecircuitbreakerisaninputdevicethatoffersshort-circuitprotection(replacinginputfuses),combinedwithapossibilityofremotelycontrollingthepowersupplyon/off(withthe+AMOoption).TheMCCBsarestandardequippedwithunder-voltagecoils.+ICO-InputContactor,230V/+TUPneeded+IFD-FuseSwitch+aRfuses,cannotbeusedwith+ILS,+IFUor+ICB,forFR13consistsofaload-switchandseparatefuses+IFU-aRfuses&base,Thisoptioncannotbeusedwith+ILS,+ICBor+IFD+ILS-InputLoadBreakSwitches,cannotbeusedwith+IFU,+ICBor+IFD.

VACONSuzhouDrivesCo.,Ltd34NXC-CompactandFlexibleSingleDrive

2.NXC-LowHarmonicSingleDrive3.NXC-Cabinetoptions4.Liquidcooledcabinets5.CustombulitContentsLiquidcooledcabinets–CH74VACONSuzhouDrivesCo.,Ltd35Voltagerange:380-690VPowerrange:600kW–1500kWUpto5300kWwithDriveSynchTechnologyEnclosureclasses:IP23orIP54Inputdevicesasoption:Aircircuitbreakerandearthingswitch(ACfusesincludedasstandard)Outputfilters:Du/Dt-filterasoptions,liquidcooled6-pulseand12-pulsesolutionNXLiquidCooledCh74LogstrupHighpowerwithdrivesyncLiquidcooledcabinets–CH74VACONSuzhouDrivesCo.,Ltd36Liquidcooledcabinets–CH74VACONSuzhouDrivesCo.,Ltd37Inputvoltage:400-500VAC;525-690VAC;(–10%…+10%)Inputfrequency:45…66HzRatedshort-timewithstandcurrent(Icw):Upto50kA/1sec(additionaloptionsmightrequirelowershort-timewithstandcurrent)Outputvoltage:0-UinOutputfrequency:0…320Hz(standard)withoutdu/dt-filter;7200Hz(Specialhighspeedversion)Outputcurrent:RatedcurrentatnominalinflowcoolingwatertemperaturMinrequiredrateofflow:130l/minforIP23solutionand150l/minforIP54solutionTemperatureofcoolingagent:0…35°C(Ith)(input)Systempressure:maxworkingpressure6barandmax.peakpressure40barAllowedcoolingagents:DrinkingwaterorWater-glycolmixtureAmbientoperatingtemperature:+5…+40CInstallationtemperature:0…60CStoragetemperature:-40..+60ºC,allliquidmustberemovedfromtheunitduringstorageifthetemperatureisbelow0ºC.Relativehumidity:5…96%,nocondensationallowedAirquality:NocorrosivegasesChemicalvapors:IEC721-3-3,unitinoperation,class3C2Mechanicalparticles:IEC721-3-3,unitinoperation,class3S2(noconductivedustallowed)Altitude:oNX_5(380...500V):max.3000m;incasenetworkisnotcornergroundedoNX_6(525...690V):max.2023m.Forfurtherrequirements,pleasecontactfactorySwitchingfrequency:400-500VACdrives1…6kHz;Factorydefault3.6kHzand525-690VACdrives1…6kHz;Factorydefault1.5kHzTechnicaldescriptionLiquidcooledcabinets–CH74VACONSuzhouDrivesCo.,Ltd38Thesolutionincludesfollowingasstandard:

UltrarapidACinputfuses

LiquidcooledACchokeDoormountedkeypadBasicI/OwiredtoexternalterminalsSupplyandmotorcablingfrombaseEMCcableglandsformotorcables

Aux.voltagetransformer750VA230VACcustomersocket

CabinetheaterThefollowingoptionsareavailablefortheliquidcooledsolution.

Inputdeviceoptions

Circuitbreaker(ACB),inc.Local/RemoteoperationswitchandEmergencystop(cat0)Earthingswitch

Outputfilteroptions

liquidcooledDu/dtfilter

Heatexchanger

HXL\M-M-120-N-S\PLiquidcooledcabinets–CH64VACONSuzhouDrivesCo.,Ltd39NXCh64CabinetSolutionRegenerativeLowHarmonicVoltagerange:380-500,500-690VPowerrange:560kW–1100kWEnclosureclasses:IP21orIP54(option)VACONDriveSynccontrolconceptforrunning4pcsofCh64drivescabinetsinparallelLiquidcooledcabinets–CH64VACONSuzhouDrivesCo.,Ltd40Inputvoltage:380-500VAC/525-690VAC;(–10%…+10%)Inputfrequency:45…66HzRatedshort-timewithstandcurrent(Icw):Upto40kA/1sec(additionaloptionsmightrequirelowershort-timewithstandcurrent)Circuitconnection:Rp2”(ISO7/1)orDN50DIN2642Tempofcoolingagent:0…35°C(Ith)(input)withoutderatingSystempressure:maxworkingpressure6barsandmax.peakpressure40barAllowedcoolingagents:DrinkingwaterorWater-glycolmixtureMainpipematerial:StainlesssteelAmbienttemp+5..+40qCInstallationtemp:+0..+70CRelativehumidity:5..96%,nocondensationallowedStoragetemperature:-40...+60ºC,allliquidmustberemovedfromtheunitduringstorageifthetemperatureisbelow0ºC.Airquality:NocorrosivegasesChemicalvapors:IEC721-3-3,unitinoperation,class3C2Mechanicalparticles:IEC721-3-3,unitinoperation,class3S2(noconductivedustallowed)Altitude:2023m.Controlmethod:FrequencycontrolU/f,openloopsensorlessvectorcontrolandclosedloopspeedcontrolSwitchingfrequency:525-690VACdrives1…6kHz;Factorydefault1.5kHz380-500VACdrives1…12kHz;Factorydefault3.6kHzTechnicaldescriptionLiquidcooledcabinets-CH64VACONSuzhouDrivesCo.,Ltd41Thefollowingisstandard

IP21cabinetWithdrawableMainBreakerSupplycablingfrombottom(upto6*[3*185mm2])InputfusesLiquidcooledLCLfilterDoormountedkeypadsBasicI/OwiredtoexternalterminalsEmergencydisconnectpushbutton(doormou

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论