1、AF ablation with 3D mapping: our technique and results,Dr Dhiraj Gupta MRCP MD DM Liverpool Heart and Chest Hospital,Northern UK AF experts Best Practice meeting Langdale Hotel, Cumbria 5 Feb 2010,Schema,Our approach to AF ablation at LHCH Our reasons for each step Our in-lab and follow-up results,O

2、ur approach in a nutshell,PVAI with Wide area circumferential ablation CT image integration using CARTO Individualised lesion set prescription Aim to ablate out of AF, ideally to SR Procedure duration limit of 5 hours,CT image registration,Critical part of the process 2 steps Single point Landmark r

3、egistration Surface Registration with Fast Anatomical Mapping Takes 5-10 minutes,CT image segmentation,Fast Anatomical Map creation,Image Surface registration,Why the individualised approach?,Heterogeneity amongst AF population Trigger removal vs Substrate Modification Aim to achieve high single pro

4、cedure success rates Incremental risk with multiple procedures Thats what the patient wants Thats what the health economists want!,Patient selection criteria,Patients not offered Catheter ablation if Very long standing Persistent AF (3 years) Very large LA (5.5 cm) Morbid Obesity (BMI 40), Sleep Apn

5、ea Significant RA dilatation (LA) Patients not offered first redo at least for 6 months Not offered Second redo if still in PsAF,Not all AF patients are the same,True PAF Short lived episodes, short history, normal sized LA Sustained PAF: 2 or more of the following AF episodes24 hours, History of AF

6、 5 years, LA size 4.5 cm, Age 65 years, Documented flutter, High AF burden (most days) Persistent AF Long standing Persistent AF (12 months),Minimum RF Lesion set,True PAF PVAI using WACA Sustained PAF + LA roof line + RA flutter line Persistent AF + LA floor line + Mitral isthmus line Long standing

7、 Persistent AF + Epicardial CS ablation+ CAF ablation,Paroxysmal PAF,Sustained PAF,Persistent AF,Long standing Persistent AF,Surgical Maze for Permanent AF,* SM Prasad et al, J Thorac Cardiovasc Surg 2003; 126: 1822-27,Still the Gold standard in terms of results 96% free of AF at 5 years*,Results wi

8、th Catheter Maze,Why CT image integration?,Forewarned is forearmed: PV anatomical variations Common Left Pulmonary Vein Additional pulmonary vein(s) Important anatomical information thickness of the LAA ridge, intervenous carina extent of the PV antra length of the mitral isthmus,Why CT image integr

9、ation?,Dramatically reduces procedural fluoro times: 10 minutes for PAF cases 10-20 minutes for PsAF cases Decreases fatigue Removes the fear of the unknown. Demystifies AF ablation for the nurses/ radiographers!,Why CARTO rather than ESI?,Unmatched catheter stability no catheter dive with onset of

10、RF delivery Allows linear lesions No need for stable intracardiac reference Ability to perform activation mapping if needed Great CT image integration software,Advances with CARTO-3,Hybrid of impedance and magnetic catheter location Ability to see all catheters Ability to create fast anatomical maps

11、 Makes CT image integration easier More streamlined patient set-up,Why WACA?,PV ostial/ antral triggers Substrate modification by Atrial debulking Less risk of PV stenosis Quicker than segmental PVI Easy to anchor linear lesions on either side Et tu, Bordeaux?!,Why our RF settings?,Continuous RF: 35

12、 W, 50C, 10 ml/ min flow Quicker signal obliteration than 30/25 W Short procedure time (20-30 per WACA) Prevents peri-lesion edema (? reconnection risk) RF controlled by Foot pedal Frees up a cardiac physiologist Imposes discipline on use of X-ray pedal!,Our results,131 consecutive pts. between Jan

13、08-July 09,Individualised ablation strategy,True PAF (n=45) PVAI using WACA Sustained PAF (n=31) + LA roof line+ RA flutter line Ps AF (n=22) + LA floor line+ Mitral isthmus line Long standing Ps AF (n=33) + Epicardial CS ablation+ CAF ablation,In-lab results,All patients received prescribed minimum

14、 lesion set Mean Procedure time 173 min (98-300) Fluoroscopy times Mean 26.5 min (13-58) (as pre-CARTO 3 era) Now with CARTO-3 (n=36): Mean 14 min (6-21) Complications 1 tamponade (PVI group), 1 AV fistula,Our follow-up strategy,Antiarrhythmic drug therapy for 2-3 months Early post-op arrhythmias DC

15、 CV if sustained and poorly tolerated (n=1) No redo ablation procedure for at least 6 months Mean follow up 11.3 months (6-24),Our Clinical Results,Definition of Procedural Success: No symptoms beyond 3 months, AND Absence of AF/AT on 24 hour Holter at 6 mo Single procedure success rates at 6 months PAF 84% PsAF 86% Sustained PAF 77% (p=0.05) Long sta

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论