1、User Instructions: SE 1794 Flex I/O Faceplates09/13/07 Rev 1.0The SE 1794 Flex I/O Faceplates files allow you to quickly load, configure, and use preconfigured status and diagnostic displays or faceplates for Flex 1794 Digital and Analog I/O using RSView Supervisory Edition.The example below shows t
2、he types of Flex I/O template objects that can be added to a specific system display. The I/O button templates can be configured to launch the on-top status and diagnostic displays or faceplates for the particular I/O modules they represent.Example of I/O Button Templates used to launch a digital an
3、d analog faceplate16System CompatibilityThe faceplate files are compatible with:RSLogix5000 V15 or laterRSView Supervisory Edition 4.0 or later.Before using faceplate files, please upgrade your RSView Studio Supervisory Edition Version 4.0 with the patches posted on or after 01/01/07.The latest RSVi
4、ew Studio Supervisory Edition 4.0 patches may be found within the Rockwell Automation Knowledgebase at the following website/ Answer ID: /knowledgebaseAnswer ID:35680NOTE: These instructions are for local or distributed I/O on EtherNet/IP and ControlNet but not Device
5、Net.The following modules are compatible with these instructions: DigitalAnalog1794-IA16/A1794-IE121794-IA8/A1794-IE4XOE2B1794-IA8I/A1794-IE81794-IB10XOB61794-IE8H1794-IB16/A1794-IE8XOE41794-IB16D/A1794-IF2XOF2I1794-IB16XOB16P1794-IF4I1794-IB32/A1794-IR81794-IB8/A1794-IRT81794-IB8S/A1794-IT81794-IC1
6、6/A1794-OE121794-IM8/A1794-OE41794-IV16/A1794-OE8H1794-OM81794-OF4I1794-OW81794-OX81794-OA16/A1794-OB16/A1794-OB16D/A1794-OB16P/A1794-OB32P/A1794-OC16/A1794-OV16/A1794-OV16P/AGeneral Setup1) After downloading your file, the following folder will be created: SE_1794_Digital&Analog_Faceplate_Files. Th
7、is folder will contain the 1794 digital and analog I/O faceplate files, the 1794 parameter file and a “SE_1794_IO_Button_Templates” folder containing the templates for the 1794 I/O modules that can be used on your display.Logix Configuration1) Open existing Logix file with RSLogix50002) Add and conf
8、igure the desired Flex I/O modules. (Skip to step 2e for distributed I/O).a. For Local I/O, right click on the FlexBus Local or Local2 and select “New Module”.b. Select the appropriate I/O module from the available listing.c. Enter a distinct module name and description.d. Repeat step 2a-2c for all
9、local Flex I/O modules.e. For distributed Flex I/O, right click on “Backplane, FlexLogix System” and select “New Module”. Then select the appropriate Communications module (i.e. 1788-CNC/A or 1788- ENBT/A) local to the controller.f. Give the new Communications module a name, a description and enter
10、the correct chassis size. For an ENBT give the IP address. For a CNB give the node number.g. Right click the Communication module you just configured and select “New Module” to add the appropriate network adapter.h. Select the appropriate adapter module for the distributed I/O you are using.i. Give
11、the new module a name, description, an IP address, and choose a chassis size.NOTE: Do not set the Comm Format to Rack Optimization for these faceplates.j. Right click on the network adapter and select “New Module”. Add the appropriate I/O module for your system.k. Enter a distinct module name and de
12、scription.l. Repeat step 2j-2k for all distributed Flex I/O modules.RSView SE Configuration1) Open your existing RSView SE application that you wish to add the Flex I/O faceplate to.2) Add the appropriate “SE_1794-Ixx_Faceplate.gfx” or “SE_1794-Oxx_Faceplate.gfx” file to your displays.a. Right-click
13、 on Displays, and select “Add Component Into Application”. Browse to the SE_1794_Digital&Analog_Faceplate_Files folder and select the faceplate GFX file that matches the module you wish to create a faceplate for.3) Add the faceplate parameter file “SE_1794_Parameter.par” to your RSView SE applicatio
14、n.a. Right-click on Parameters, and select “Add component Into application”. Browse to the SE_1794_Digital&Analog_Faceplate_Files folder and select the “SE_1794_Parameter.par” file. Then click the Open button.b. Now open the parameter that was just added and edit the “parameter tagname” to match you
15、r application. The “parameter tagname” needs to include the RSLinx Enterprise “Device Shortcut” name of your systems controller and the Logix “tag name” of the intended Flex I/O module you wish to monitor.i. Double-click on the faceplate parameter file, and edit the “Device Shortcut” name(in this ex
16、ample it is CLX-L43) to match the Logix controller that was previously configured in your RSLinx Enterprise Communication Setup.ii. Enter the Logix “tag name” of the intended Flex I/O module to monitor.For modules that are local, this tag name will be the name “Local” followed by a “:” and the slot
17、location of the module, ie., Local:1For modules that are distributed, this tag name will be the name of your adapter you added in step 2h of the Logix Configuration section, followed by a “:” and the slot location of the module,i.e. Network_Adapter:1Close and Save changes.To add parameter files for
18、additional Flex I/O modules, simply repeat steps 3a and 3b above, creating a unique parameter name by assigning the associated “Device Shortcut” and Logix “tag name” for each module.For modules that are local, change only the slot location of the tag name, Example: #1=CLX-L43Local:2 represents a mod
19、ule in slot 2.For modules that are distributed, this tag name will be the name of the additional I/O adapters, followed by a “:” and the slot location of the module.Example: #1=CLX-L43Network_Adapter_2:1 (“Network_Adapter_2” represents another unique name for an I/O adapter on the network and “:1” r
20、epresents the module in slot 1.)4) Create the display navigation to open the 1794 I/O Faceplates at runtime. (To use the I/O button templates for the 1794 Modules skip to pg 11, Configuration Steps for using the I/O Button Templates.)a. On a desired graphic display, create a new button object.on obb
21、. Double-click on the buttject to display its properties and configure the Action tab. Click onthe browse (i.e. ellipses,) button beside the Press Action field to launch the Command Wizard.c. Select the Display command and click Next.d. Use the browse buttons, drop down menus and the Parameter File
22、checkbox to select the appropriate area, display and parameter file name and click Finish.e. The Display command syntax has now been configured and inserted into the Press Action field.f. Configure the remaining Button Properties if desired and click OK.g. Repeat steps 4a-4f for navigation to any ad
23、ditional Flex I/O modules, using a unique parameter file for each additional Flex I/O module.5) Now, you can save and create a runtime file to test your display.Configuration Steps for using the I/O Button TemplatesIf you desire a hardware system view as shown below, with each module in the chassis
24、configured as a display navigation button that can launch individual Flex I/O faceplates, follow these instructions.1) Add the 1794 bitmap images into your RSView application by right clicking onto the Image folder in the system tree and choosing “Add Component into Application.”2) Browse to your “S
25、E_1794_IO_Button_Templates” folder that was created in step 1 under General Setup. Select all the 1794 Bitmaps images. Click Open.3) Next, add the 1794 display navigation files into your RSView Application by right clicking on the Display folder in the system tree and by selecting “Add Component int
26、o Application.”4) Browse to your “SE_1794_IO_Button_Templates” folder and select all the GFX files. Click Open. Verify the displays appear under Displays in your system tree.5) Create a new Display or open your own system display to copy the I/O button templates to.6) Open the “Goto_Flex_Adapters_an
27、d_Controllers” displays and copy (or drag and drop) your desired graphic object onto your system display.7) Open the “Goto_Flex_Input_Modules” or “Goto_Flex_Output_Modules display and copy (or drag and drop) your desired modules onto the display.8) Repeat step 7 until all the required modules have b
28、een copied onto the chassis.9) Double click twice on a module to launch the button properties (be sure to click near the top of the module to open the Button properties and not the “text” object properties). Or right click on the display area and select Object Explorer to use its object list.10) To configure the Action tab, click on the browse (i.e. ellipses, ) button beside the Press Action field to launch the Command Wizard.11) Select the Dis
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026小学数学教资面试试讲全真模拟题库及解析
- 2026初中数学教资面试答辩高频题考题题库及解析
- 初中数学2026教资面试强化训练全真模拟
- 风电场工程道路设计规范
- 房地产资源课件
- 糖尿病眼部的护理
- 腰2椎体骨折护理查房
- 房地产发展历程课件
- 福鼎白茶培训课件
- 分层走班课件
- 一年级上册数学期中质量检测卷(青岛版五四学制)(含答案)
- 2026年行政执法人员试题库及答案
- 2026秋新教材人教PEP版六年级上册英语全册教案(单元整体教学设计)
- 2026新教科版四年级科学上册第一单元第5课《空气流动有力量》课件
- 2026年广东省春季高考(学考)语文真题(含解析)
- 2026年资产评估师资产评估实务(二)考试真题及答案
- 2025 先进涂层材料及表面处理技术研讨会:SAE AS1701F标准及其适用的干膜润滑剂介绍
- 中古珠宝专业知识培训课件
- 蒙古族酒盅舞教学课件
- 员工心理健康管理与疏导策略
- 宗许宁船舶管理电子电气员92课件
评论
0/150
提交评论