版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
DocumentDraftedCheckedReviewedApprovedModification-BPLANTPHASEI(2×1000MW)文件编DOC. DocumentDraftedCheckedReviewedApprovedModification-BPLANTPHASEI(2×1000MW)文件编DOC. 题SYSTEMMANUAL-RRICHAPTERFunction,GeneralDesign,DescriptionandDefinitionofEquipment,OperatingParameters工程Project文件类Document子项Sub-Item设计阶段EngineeringSDA:B:√C: 深圳中广核工程设计有限公司NationalAgradeengineeringCertificationNO:CHINANUCLEARPOWERDESIGNCOMPANY,LTD NationalAgradeengineeringCertificationNO:内部编码InternalCP0905-HX-GN-ThisdocumentisthepropertyofCNPDCItmustnotbeused、reproduced、transmittedordisclosedwithoutthepriorwrittenpermissionofCNPDC本文件之产权属于中广核工程设SYSTEMMANUAL-RRICHAPTER2-Rev版本记REVISION版日状编Drafted校Checked审Reviewed批Approved修改Modification-ASYSTEMMANUAL-RRICHAPTER2-Rev版本记REVISION版日状编Drafted校Checked审Reviewed批Approved修改Modification-ASYSTEMMANUAL-RRICHAPTER2-BPLANTPHASEI(2×1000MW)SYSTEMMANUAL-RRISYSTEMMANUAL-RRICHAPTER2-BPLANTPHASEI(2×1000MW)SYSTEMMANUAL-RRI2,3,4,5Function,GeneralDesign,DescriptionandDefinitionofEquipment,OperatingParametersSYSTEMMANUAL-RRICHAPTER2-Rev文件修改记SYSTEMMANUAL-RRICHAPTER2-Rev文件修改记版日章页修改范围AB2010-1-2011-5-3ModifyaccordingtotheTEGflowdiagram. ModifyaccordingtothemodificationofaddingemergencymakeupwatersourceforRRI.ModifyaccordingtothedesigningrequestofallusersoftheRRIsystem.Adddetaileddataaccordingtothesupplier.SYSTEMMANUAL-RRICHAPTER2-Rev SAFETY SYSTEMMANUAL-RRICHAPTER2-Rev SAFETY GENERAL Designbasesandsafety Equipment Choiceofmaterials- Equipment Equipment DESCRIPTIONANDDEFINITIONOF General Interconnectionwithother Detailofheat Sizingand Normal PARTICULARSTEADY Operatingmodeassociatedwithunit Operatingmodeassociatedwithbringingtheunittocoldshutdown4to20afterreactor Operatingmodeassociatedwithbringingtheunittocoldshutdown4to20afterreactorshutdownwithoneRRItrainavailable(subcritical Operatingmodeassociatedwithmaintainingcoldshutdown20hoursafterSYSTEMMANUAL-RRICHAPTER2-Rev Accident PARTICULARSYSTEMMANUAL-RRICHAPTER2-Rev Accident PARTICULARTRANSIENT Change-overfromonetraintothe OutageofaRRI STARTUPANDNORMAL OTHER LossofaRRItrainonsysteminRRA Demineralizedwatermake-up.Functionofsurgetanks1/2RRI001BAand LossofoneRRItrainonsysteminRRAconfigurationwithdemineralized(SED)not CoolingofbothRRApumpsbythesameRRI OTHER APPENDIXCONCEPTFLOW APPENDIXHEATLOADSANDRRIWATERFLOWRATESTOTHE APPENDIXRRIcoldtemperatureforeachoperating SYSTEMMANUAL-RRICHAPTER2-Rev 2.1Themainfunctionsofthecomponentcoolingsystem(RRI)tocoolthevarious"NuclearSYSTEMMANUAL-RRICHAPTER2-Rev 2.1Themainfunctionsofthecomponentcoolingsystem(RRI)tocoolthevarious"NuclearIsland"heattotransfertheheatloadtoanultimateheatsink,i.e.:theseawater,throughheatexchangerscooledbytheessentialservicewatersystem(SEC),toprevent,byformingabarrierbetweenNuclearIslandheatexchangersandthewateruncontrolledreleaseofradioactivefluidsintotheseaCooledheatexchangersmaybedividedintothreecategories(detailedontable"Safeguard"heatexchangers,so-calledbecausetheyareessentialfordealingwithconditionIIIorIVaccidents.Heatexchangersessentialforequipmentwhichistobecooledundernormaloperatingconditions,andifalossofoffsitepoweroccurs.Heatexchangerswhichareusedundernormaloperatingconditions,butareabsolutelyessentialimmediatelyafteralossofoffsiteabcContainmentspray-1/2EAS001RF-1/2EAS001MO√√√Chilledwatersystemofelectrical-1/2DEL001CS√√√ √√√Safetyinjection-1/2RIS001MO√√Componentcooling-1/2RRI001,003MOPO(1/2RRI002,004MO√√√SYSTEMMANUAL-RRICHAPTER2-RevabcContainmentAtmosphereMonitoring-0ETY001RV√Residualheatremoval√√√√Reactorcoolant-1/2RCP001,002,003MO-1/2RCP002BAPressurizerrelief√√√Chemicalandvolumecontrol1/2RCV003RFsealingofSYSTEMMANUAL-RRICHAPTER2-RevabcContainmentAtmosphereMonitoring-0ETY001RV√Residualheatremoval√√√√Reactorcoolant-1/2RCP001,002,003MO-1/2RCP002BAPressurizerrelief√√√Chemicalandvolumecontrol1/2RCV003RFsealingofprimary1/2RCV002RFnonregenerativeheat1/2RCV021RFexcessletdownheat√√√√√Controlroddrivemechanismventilation-1/2RRM001,002,003,√√Chilledwater-1/2DEG101,201,√√Steamgeneratorblowdown-√Nuclearsampling-1/2REN√Reactorcavityandspentfuelpitcooling-1/2PTR001,002RF,√Hotlaundryventilation-√Boronrecycledandliquidwastetreatment-TEPandTEU√GaseouswastetreatmentSYSTEMMANUAL-RRICHAPTER2-RevBNOTE:RRAsystem(pumpsandheatexchangers)SYSTEMMANUAL-RRICHAPTER2-RevBNOTE:RRAsystem(pumpsandheatexchangers)isnotnecessaryincaseofLOCA,isnecessaryincaseofsmallleakageorsteampipe2.2SAFETYThecomponentcoolingsystem(RRI)mainsafetyfunctionsInconnectionwiththeessentialservicewatersystem(SEC)totransferheatfromimportantsafety-relatedstructures,systemsandcomponents,toanultimateheatsinkwhichistheseawater.Ittransfersthecombinedheatloadofthesestructures,systemsandcomponents,undernormaloperationandaccidentconditions.Fromahealthphysicspointofview,thecomponentcoolingsystem(RRI)incaseofaleakageofacooledheatexchangerwhichisorcouldbecontaminated,anuncontrolledreleaseofradioactivefluidsintotheseawater.abc-1TEG001RF,√Auxiliarysteamdistribution-CoolerforKRTanalysis√SYSTEMMANUAL-RRICHAPTER2-Rev GENERAL3.1DesignbasesandsafetySYSTEMMANUAL-RRICHAPTER2-Rev GENERAL3.1DesignbasesandsafetyThecomponentcoolingsystemcircuitisaclosedloopbetweennuclearauxiliarysystemcomponentsandseawater.TheRRIsystemisdesignedtoprovidecoolingwateratamaximum-of35℃duringnormalplantoperationatnominalpower,keepingatcoldshutdown20hafterreactorshutdown,withamaximumseawatertemperatureof33.5℃.of40℃duringplantstartup,coldshutdownbetween4&20hafterreactorshutdown,subcriticalshutdown,withamaximumseawatertemperatureof33.5℃.of45℃duringlossofcoolantaccident(LOCA),withamaximumseatemperatureof--Systemcoolingcapacitycorrespondstotheheatloadsofindividualcomponentsneedtooperatesimultaneouslyunderdifferentplantoperatingplantnormalplantoperationatnominalresidualheatremovaltoachieveandmaintaincoldshutdown,subcriticalshutdown(onlyoneRRItrainavailable),TheRRIsystemisdesignedtomeetthefollowing SAFETY ReferenceLNPS1and PRCRCCPcodeapplicationnote§2.3.6and§2.1.3.RCC-Psupplementcodeapplicationnote2.5.SARchapter -ReferencetoparticularrulesandAFNOR,RCC-M,ANSIB16.34,CODAP,RCC-ESYSTEMMANUAL-RRICHAPTER2-Rev RCC-PConditionsincaseoflossoftheRRIsafetySYSTEMMANUAL-RRICHAPTER2-Rev RCC-PConditionsincaseoflossoftheRRIsafetypartcomplieswith Activecomponent Plateheatexchangers: ElectricalElectricalredundancy5ENVIRONMENTAND Separationofredundant-ActiveYes,forsafetytrains(separatedNo,forredundantcomponentsthesame-Passive Externalattacksagainstwhichsystemis--Steam-Pipe-Turbine-Miscellaneous-Airplane-SafeshutdownYes,exceptedpipeconnectedto 1/2RRI700VNand1/2RRI552VNoutlet)andDWLsystem(between9RRI063DIand--NotRevTheportionofthesystemcoolingtheheatexchangersonsafeguardsystemsisdesignedtakingintoaccountthesinglefailurecriterionandthepossiblelossofon-siteoroff-sitepowersuppliers.Consequently,theRRIcircuitcomprisestwoseparatesafeguardtrains,suppliedbytrainsAandBwhicharebackedupRevTheportionofthesystemcoolingtheheatexchangersonsafeguardsystemsisdesignedtakingintoaccountthesinglefailurecriterionandthepossiblelossofon-siteoroff-sitepowersuppliers.Consequently,theRRIcircuitcomprisestwoseparatesafeguardtrains,suppliedbytrainsAandBwhicharebackedupbydieselgenerators,andthecomponentscommonloop,suppliedbyoneofthetwotrains.-Noxiousvaporsorgases(otherthosecausedbyNot-Liquids(escapingfrombreaksin-IonizingNot-Explosions:fromin-Not-ParticularprecautionsagainstRCC-I(1983+codenote1987)+RCC--TornadoandinducedNot Attacksonother-Pipe--Noxiousvaporsorgases(otherthosecausedby-Flooding-Ionizing-- In-service Periodic Outsidecontrolledareabutcircuitsareinsidecontrolled ProtectionagainstSYSTEMMANUAL-RRICHAPTER2-Rev3.2EquipmentSYSTEMMANUAL-RRICHAPTER2-Rev3.2EquipmentDesignconditionsforequipmentareas-RRI/SECheatexchangers:heatexchangesurfaceisissuedfromthethermalcalculationresults,establishedbytheRRI/SECplatetypeheatexchangermanufacturer,whichshowsthat"Normaloperatingconditions"isthesizingcase.RRI/DEGheatexchanger:sizingissuchthatitallowsfeedingthelowtemperatureRENheatexchangerswithRRIcoolingwater,subcooledtoatemperaturelessthanequalat30℃,inordertoobtainthesampletobeanalyzedcooledtoatemperature-about35℃(seedatasheets1/2RRI005RFheatexchangeronchapterPumps:nominalflowrate(producedbyonepump)isdeterminedbynormaloperation,totalheadbeingdeterminedbythelegprovidingthegreatestpressurelosses.Designallowsforloadfollowasregardswastetreatmenti.e.,twoTEPgasstripperevaporatorunitsoncontinuous--3.3Choiceofmaterials-3.3.1EquipmentPlatetypeheatexchangerwithtitaniumplates.Pumpcasingsmadeofcarbonsteel.Carbonsteelforpipingand3.3.2EquipmentSeeequipmentclassificationlist:SYSTEMMANUAL-RRICHAPTER2-Rev DESCRIPTIONANDSYSTEMMANUAL-RRICHAPTER2-Rev DESCRIPTIONANDDEFINITIONOFTheRRIcircuitisrepresenteddescribedinflowdiagrams:GeneralForeachunittheRRIcircuitcomprisestwoseparatesafeguardtrainsandacommonsuppliedbyboth4.1.1.1SafeguardThepartoftheRRIwhichisessentialforreactorsafeguardandcooldownis100%redundant.Thecircuitthereforecomprisestwoindependenttrains,suppliedrespectivelybyelectricallinesAandB,eachofwhichcanprovide100%essentialcoolinginthecaseofanaccident.Eachtrainconsists-two100%centrifugalpumps(1/2RRI001POand1/2RRI003POontrainA,1/2RRI002POand1/2RRI004POontrainB),SYSTEMMANUAL-RRICHAPTER2-RevtwoRRI/SECheatexchanger,dividedintotwo50%capacityportions(1/2RRI001RFand1/2RRI003RFontrainA,1/2RRI002RFand1/2RRI004RFontrainB),wheretheheatistransferredtoSECwater,atpumpdischarge,oneRRISYSTEMMANUAL-RRICHAPTER2-RevtwoRRI/SECheatexchanger,dividedintotwo50%capacityportions(1/2RRI001RFand1/2RRI003RFontrainA,1/2RRI002RFand1/2RRI004RFontrainB),wheretheheatistransferredtoSECwater,atpumpdischarge,oneRRIsurgetank(1/2RRI001BAontrainA,1/2RRI002BAontrainB),connectedthesuctionlegsonthepumps.Thesesurgetanks,whichprovidesuctionheadforthecompensationforcontractionandpossiblepressurepulseareventedtothenuclearauxiliarybuildingventilationsystem(DVN),sincetheymaycontainradioactiveelements.Corrosioninhibitingagentscanbeinjectedfromthechemicalreagentsinjectionsystem(SIR)totheRRIwater.DemineralizedwaterdistributionsystemforNuclearIsland(SED)isusedformakeup.UndertheSafetyShutdownEarthquake(SSE)condition,withSEDsystemunavailableand"distresslevel"alarmappearedforthesurgetankoftheoperatingRRItrain,nuclearislandfireprotectionsystem(JPI)isusedformakeup.Eachtrain-oneheatexchangerfromthecontainmentspraysystem(1/2EAS001RFontrainA-1/2EAS002RFontrainB),oneheatexchangerfromthechargingpumproomemergencyventilationsystem(1/2DVH001RFontrainA-1/2DVH002RFontrainB),onecondensersfromtheelectricalbuildingchilledwatersystem(1/2DEL001CSontrainA-1/2DEL002CSontrainB)althoughtheDELisnotasafeguardsystem,oneheatexchangerfromtheresidualheatremovalsystem(1/2RRA001RFontrainA-1/2RRA002RFontrainB),onehydrogenrecombinerfromcontainmentatmospheremonitoringsystem(0ETY001RVontrainA–0ETY002RVontrainB)(RRIonlysupplyingcoolingwaterinLOCAcondition),thecoolingsystemforthefollowingpumpsandpumpTrainATrainBSYSTEMMANUAL-RRICHAPTER2-RevForequipmentitemsonSYSTEMMANUAL-RRICHAPTER2-RevForequipmentitemsonredundanttrains,electricalsupply,control,monitoringthedieselsetback-upsupplyareseparatedintotwoseparatelinesAandB,eachofisassignedtoa4.1.1.2CommonloopCoolingwaterdistributiontothecoolersnotrequiredtoserveduringaccidentconditionsissuppliedbyeitherredundantloopandcanbeisolatedfromthesafeguardtrainsofthesystembyelectricallymotorizedvalves(1/2RRI041VNand1/2RRI058VNfortrainA,1/2RRI040VNand1/2RRI059VNfortrainB).Thislegcoolsthefollowingcondensersofthechilledwaterproductionanddistributionsystemthenonregenerativeheatexchangerofthesteamgeneratorblowdownsystem(APG),reactorcoolantpumpsandpressurizerrelieftank,excessletdownheatexchanger,non-regenerativeheatexchangerandsealwaterheatexchanger,thesethreeheatexchangersinterfacewithandarepartofthechemicalandvolumecontrolsystem(RCV),heatexchangersofthereactorcavityandspentfuelpitcoolingsystem(PTR),thesethreeexchangerscooledontheRRIsideonlywhentheRRIcommonusersaresystematicallysuppliedbytheotherunit,heatexchangersofthenuclearsamplingsystem(REN);forsomeofthem(lowtemperatureheatexchangers),afractionoftheRRIwaterflowissubcooledin1/2RRI005RFbychilledwaterfromtheDEGsystem,aircoolersofthecontrolroddrivemechanismventilationsystem-B--TheaboveequipmentisassignedtoeachplantThecommonloopalsosuppliescoolingwatertoequipmentsharedbetweenbothplantboronrecyclesystem(TEP)evaporatorsandgasstrippers,liquidwastetreatmentsystem(TEU)evaporator,gaseouswastetreatmentsystem(TEG)compressorheatexchangerformonitoringactivityofcondensatesfromtheauxiliarysteamdistributionsystem(SVA),SYSTEMMANUAL-RRICHAPTER2-Rev-hotlaundryventilationsystemTheseequipmentcanbecooledbytheRRIsystemofeitherplantunit(switchoverisachievedbyactuatingmotoroperatedvalves9RRI044VN,9RRI045VN,9RRI322VN,ThePTRheatexchangerscanbeemergencysuppliedfromtheotherplantunit.Manuallyoperatedvalves1/2RRI043VNand1/2RRI205VNmakeitSYSTEMMANUAL-RRICHAPTER2-Rev-hotlaundryventilationsystemTheseequipmentcanbecooledbytheRRIsystemofeitherplantunit(switchoverisachievedbyactuatingmotoroperatedvalves9RRI044VN,9RRI045VN,9RRI322VN,ThePTRheatexchangerscanbeemergencysuppliedfromtheotherplantunit.Manuallyoperatedvalves1/2RRI043VNand1/2RRI205VNmakeitpossibletoisolatethePTRheatexchangersfromtheRRIsystemoftheplantunit.Thenthesupplyisensured,viatheheaderscommontobothplantunits,fromtheother4.1.2InterconnectionwithotherRRIsystem-Steamgeneratorblowdown-NuclearIslandchilledwater-ElectricalBuildingchilledwater-Chargingpumproomemergencyventilation-Hotlaundryventilation-Containmentspray-Reactorcavityandspentfuelpitcoolingand-Reactorcoolant-Chemicalandvolumecontrol-Nuclearsampling-Safetyinjection-Residualheatremoval-Controlroddrivemechanismventilation-Auxiliarysteamdistribution-Gaseouswastetreatment-Boronrecycle-Liquidwastetreatment-ContainmentatmospheremonitoringFluidsystemSYSTEMMANUAL-RRICHAPTER2-Rev-Componentcoolingroomsventilation-Nuclearauxiliarybuildingventilation-NuclearIslandFire-Ventanddrainsystem(nuclear-InstrumentcompressedSYSTEMMANUAL-RRICHAPTER2-Rev-Componentcoolingroomsventilation-Nuclearauxiliarybuildingventilation-NuclearIslandFire-Ventanddrainsystem(nuclear-Instrumentcompressedairdistribution-Essentialservicewater-Demineralizedwaterdistributionsystem(nuclear-ChemicalreagentsinjectionElectricalsystem--110VDCPowersupply(train-110VDCPowersupply(NuclearAuxiliary-Unit48VDCPowersupply(train-Unit48VDCPowersupply(train-Common48VDCPowersupply(Nuclear-6.6kVACEmergencyPowerDistribution(train-6.6kVACEmergencyPowerDistribution(train-LVACNetwork380V(NX-LVACEmergencynetwork380V(train-LVACEmergencynetwork380V(train-Vital220VACPower(protectiongroup-Vital220VACPower(protectiongroup-Vital220VACPower(protectiongroup-Vital220VACPower(protectiongroup----OtherSYSTEMMANUAL-RRIRevThemaximumheattoevacuatedandtheminimumcoolingflow,withtemperatureconditionsspecifiedin§3.1.,foreachusercooledbytheRRIisdetailedonthefollowingtable,foreachcaseofnormaloraccidentoperation(seeAPPENDIX4.2).Foreachoperatingcaseconsideredinchapter3.1,theRRItemperatureSYSTEMMANUAL-RRIRevThemaximumheattoevacuatedandtheminimumcoolingflow,withtemperatureconditionsspecifiedin§3.1.,foreachusercooledbytheRRIisdetailedonthefollowingtable,foreachcaseofnormaloraccidentoperation(seeAPPENDIX4.2).Foreachoperatingcaseconsideredinchapter3.1,theRRItemperature(outletoftheRRI/SECheatexchanger)isshowedinthefollowingtableinAPPENDIX4.3.ThistableshowsthenormaloperatingconditionsisthesizingcaseoftheRRI/SECheatintheotheroperatingcases,themaximumRRIdesigntemperatureisneverDetailofheatEffluentRRIflowsandevacuatedheatloadareasfollowsTEU-Condenser-Distillatecooler-Auxiliarysteamcondensatecooler-EvaporatorrecirculationpumpTEPevaporator(2sets)per-Evaporatordistillatecondenser(9TEP003or--TXS-Testdata-PlantcomputerInformationandcontrol-Remoteshutdown-Plantradiationmonitoring-Maincontrol-ReactorprotectionSYSTEMMANUAL-Rev4.2.2.2CoolingofRCP*foreachRCPpump,therearetwoStartupandnominaloperatingconditions.Coldshutdownbetween4hand20h.ForservicingRRI HEAT UpperLowerSYSTEMMANUAL-Rev4.2.2.2CoolingofRCP*foreachRCPpump,therearetwoStartupandnominaloperatingconditions.Coldshutdownbetween4hand20h.ForservicingRRI HEAT UpperLowerMotoraircoolers(foreachThermal134.8-Evaporatordistillatecooler(9TEP003or-Evaporatorconcentratecooler(9TEP005or9-EvaporatorSVAcondensatecooler(9TEP007orTEPgasstrippers(2sets)per-Gasstrippercondenser(9TEP001or5-Gasstripperwastecooler(9TEP001or-GasstripperSVAcondensatecooler(9TEP009or-Gasstripperdrainingpumpmotor(9TEP003orTheflowandtheheatloadtakenintoaccountontheprevioustablecorrespondtosimultaneousutilizationoftwogasstrippers,twoTEPevaporatorsandoneTEUTEGDWLSYSTEMMANUAL-RRICHAPTER2-RevSYSTEMMANUAL-RRICHAPTER2-Rev SinceRRIflowrateisnotregulated,theflowrateof350.4m3/hisobtained(seetablepage30).4.2.2.3CRDMventilationThecoolingcircuitfortherodmechanismventilationcomprisestwoparallellegs,withtwo50%exchangersinseries.AllfourexchangersarepermanentlysuppliedbytheRRI.AsingleexchangerperlegevacuatesRRMheatload.4.2.2.4ChilledwatercondenserTheDEGcircuitincludesthree50%chillerOneortwosetsarepermanentlysuppliedbythe4.2.2.5SpentfuelpitThePTRcircuitincludesthreeplateheatThevaluestakenintoaccountinthetableofRRIrequirementsonnormaloperationare542.25m3/h.OnlyoneisrequiredtocoolbyRRIwater.Duringtherefueling,twoheatexchangersarecooledbyRRIwater.ThetwoheatexchangersareinparallelontheRRIside.Theflowrateis542.25m3/hforeachofthetwo.DuringtherefuelingandusingforbackupofRRAsystem,thethreeheatexchangersarecooled.Twoheatexchangers,inparallelwiththethirdoneontheRRIside,arecooledinseries.Theflowrateis542.25m3/hforeachloop.BeforetherefuelingstartsandusingforbackupoftheRRAsystem,RRIsystemsupplieseachoftwoheatexchangerswithcoolingwater,oneofwhichmustbePTR002RF.Theflowrateis542.25m3/hforeach.ThetwoexchangersaresetinparallelontheRRIside.ThesetupofPTRheatexchangersontheRRIsideisactualizedbyoperatorsviathemanualvalvesonthepipes.FlowdistributionontheRRIsideisensuredbytherestrictingorificeplate.Theporediameteroftheorificeplateissetbeforehandduringthecommissioningphase.Note:Duringtherefueling,thecommonuserstobothplantsaresystematicallybytheother4.2.2.6Non-regenerativeheatexchangerThevaluestakenintoaccountinthetableofRRIrequirementsonnormaloperationareoccasionalandcorrespondtotheborationphaseoftheprimarycircuitbeforebeginningofcoldshutdown.Duringnormalunitoperation,thecorrespondingvaluesareSYSTEMMANUAL-RRICHAPTER2-Revand4.2.2.7SteamgeneratorblowdownThevaluestakenintoaccountonthetablecorrespondtomaximumblowdownflowrate4.2.3SizingandCarbonsteelisusedinmanypipesandvalves.TheSYSTEMMANUAL-RRICHAPTER2-Revand4.2.2.7SteamgeneratorblowdownThevaluestakenintoaccountonthetablecorrespondtomaximumblowdownflowrate4.2.3SizingandCarbonsteelisusedinmanypipesandvalves.TheRRI/SECheatexchangersare"plate"type.Butterflyvalvesareusedfordiameters65mm(included)andaboveandglobetypefordiameterslessthan65mm.Containmentisolationvalvesaregatetype.Surgetanks,heatexchangersandpumpsaredetailedinthedatasheets(chapterTheRRIwatercharacteristicsareasElectricalconductivityat pHat11to6toMeshsize(duringChlorides+ controladditivePO3-4100toSuspended-NormalSYSTEMMANUAL-RRICHAPTER2-RevActivityActivityismonitoredcontinuously(pumpsoutlet).Themonitoringalarmsinthecontrolroom(seeKRTmanual).4.3ThevariousRRIcircuitcomponentsarelocatedasdetailedBUNITUNITLEVELOFRRIequipmentSYSTEMMANUAL-RRICHAPTER2-RevActivityActivityismonitoredcontinuously(pumpsoutlet).Themonitoringalarmsinthecontrolroom(seeKRTmanual).4.3ThevariousRRIcircuitcomponentsarelocatedasdetailedBUNITUNITLEVELOFRRIequipmentspecificto (1/2RRI001-NE712-NF722--RRIplateheat(1/2RRI001toNE260-NF262- RRI- -RRIpumps(1/2RRI0011/2RRI004MO-NE360-NF362-Coolersspecifictoone-Containmentspray·1/2EAS001--·1/2EAS001-K110-K150Safetyinjection1/2RIS001-K112-K152Chilledwatersystem-PerturbedSYSTEMMANUAL-RRICHAPTER2-RevUNITUNITLEVELOFTHEAREA(m)1/2DEL001- emergencyventilation1/2DVH001--Residualheatremoval·1/2RRA001--·1/2RRA001- SYSTEMMANUAL-RRICHAPTER2-RevUNITUNITLEVELOFTHEAREA(m)1/2DEL001- emergencyventilation1/2DVH001--Residualheatremoval·1/2RRA001--·1/2RRA001- monitoring-Chilledwater1/2DEG101-201--Steamgenerator-Reactorcoolant·1/2RCP001-002-003MO- -Chemicalandvolume·sealingofprimary exchangerRevBAREAFLOORLEVELTHECoolerscommontobothUNITUNITLEVELOFTHEAREA(m) exchanger-Controlroddriveventilation1/2RRM001-002-003-RevBAREAFLOORLEVELTHECoolerscommontobothUNITUNITLEVELOFTHEAREA(m) exchanger-Controlroddriveventilation1/2RRM001-002-003--Reactorcavityandspentpitcooling1/2PTR001-002--Nuclearsamplingsystem·hightemperaturecoolersRCPandRRA1/2REN002-1/2REN001-·hightemperaturecoolers (1/2REN071to073RF)·lowtemperaturecoolersRCP,RRAandRCVlines(1/2REN011to016RF)·lowtemperaturecoolersonSGblowdownlines(1/2REN041to044RF081toRevBBAREAFLOORLEVELTHE-TEP,TEU·TEPgasNC300-·TEPND306-RevBBAREAFLOORLEVELTHE-TEP,TEU·TEPgasNC300-·TEPND306-·TEU (9TEP009-NC231-·evaporator9TEP007--TEGcompressorNB393- KRTcoolers--Hotlaundryventilation-SYSTEMMANUAL-RRICHAPTER2-RevSYSTEMMANUAL-RRICHAPTER2-RevOPERATINGRRIconfigurationscorrespondtounitoperation.NormaloperationoftheRRIsystemcorrespondstonormalunitpoweroperation.ConfigurationsaredescribedNormalAllcoolersaresuppliedbyonetrain,theotheroneisshutdown.CoolerscommontobothunitsaresuppliedeitherbyRRIunit1orRRIunit2.Oncethesensor-outletoftheRRI/SECheatexchangers)appearsanalarminKICsystem,theoperatormuststarttheotherpumpofthesameSECtrainmanually.Whenasinglepumpofonetrainisinservice,allpumpsoftheothertrainareshutdown.Onepumpoftheshutdowntrainmaybeisolatedformaintenance.Asensorforeachpump(1/2RRI003SDfor1/2RRI001PO,1/2RRI005SDfor1/2RRI003PO,1/2RRI004SDfor1/2RRI002PO,and1/2RRI006SDfor1/2RRI004PO)givesanalarminthecontrolroom,incaseoflowmotorpumpcoolingPARTICULARSTEADYOperatingmodeassociatedwithunitNormally,onepumpisrequiredsincethecoolerscommontobothunitsarecooledbyotherunit.Twopumpswillberequiredifcoolerscommontobothunitsarecooledbytheunitonstartup.5.2.2Operatingmodeassociatedwithbringingtheunittocoldshutdown4to20afterreactorOnetrainwithonepumponlysuppliesoneoftheRRAheatexchangers.Theothertrain,withtwopumps,suppliestheotherRRAheatexchangerandallcoolersofthecommonNormally,coolerscommontobothunitsarecooledbytheother5.2.3Operatingmodeassociatedwithbringingtheunittocoldshutdown4to20afterreactorshutdownwithoneRRItrainavailable(subcriticalSituationiscorrespondingtothelossofoneRRItrainduringtheshutdowntransient.Inthiscase,thesizingoftheRRIheatexchangerpermitstokeeptheprimarycoolanttemperaturebelowSYSTEMMANUAL-RRICHAPTER2-Rev5.2.4OperatingmodeassociatedwithSYSTEMMANUAL-RRICHAPTER2-Rev5.2.4Operatingmodeassociatedwithmaintainingcoldshutdown20hoursafterAfter20hours,intheactualoperatingconditionsoftheplantunit(seawatertemperature,heattoberemoved...),theoperatingmodewithtwopumpsofonetrainandonepumpoftheothertraininservice,ismaintained.Afterabout48hours,oneRRIpumpcanbestopped.RRApumpcorrespondingtotheshutdownRRItrainmustbestoppedorsuppliedmanuallybytheRRItraininoperation(see§5.5.4.).Oncethesensor(1/2RRI081/082MT-outletoftheRRI/SECheatexchangers)appearsanalarminKICsystem,thecoolerscommontobothunitsmustbecooledbytheothertrain.AndtheoperatorshouldswitchoverthecoolerstotheothertrainAccidentContainmentThe"phaseAcontainmentisolation"signalactuatesclosureofthefollowingcontainmentpenetrationpipevalves: pressurizerrelieftankandexcessletdownheatexchanger(1/2RRI318VN,300VN,304VNandThe"phaseBcontainmentisolation"penetrationpipe-RRAheatexchangersisolationvalves:1/2RRI011VN,019VN,021VN1/2RRI012VN,020VN,1/2RRI210VNto212VN1/2RRI283VNto1/2RRI280VNto--RRMheatexchangersisolation1/2RRI170VN,177VN,5.2.5.2ContainmentThe"containmentspray"signaltheEASheatexchangerpneumaticisolationvalvestoopen(TrainA:1/2RRI035VN,TrainB:1/2RRI036VN),toclosethetwoisolationvalvesofthecommonloop,whichwereopen,andtoSYSTEMMANUAL-RRICHAPTER2-SYSTEMMANUAL-RRICHAPTER2-Revthatthetwoothersvalvesoftheothertrain(trainA:1/2RRI041VNand1/2RRI058VN,trainB:1/2RRI040VNand1/2RRI059VN)areclosed.ThussafeguardtrainsonlyaretostartuponepumpofthetrainonstandtomaintaintheinitialstatusofthetraininoperationwithoneortwoPTRcoolerswhicharenomoresuppliedmaybemanuallysuppliedfromtheotherunitbyclosingvalves1/2RRI043VNand1/2RRI205VNoftheunitunderaccident,andopeningmotoroperatedvalves9RRI044VNand9RRI322VN(Unit1),9RRI045VNand9RRI323VN(Unit2).5.2.5.3SafetyOn"safetyinjection"signal(seeRISsystemmanual),startupofthesinglepumponlinewhichwasshutdown.PumpsonthelineinoperationremaininPARTICULARTRANSIENTChange-overfromonetraintotheOnetrainonlyoperatesundernormalconditions(see§5.1.).Itsuppliestheheatexchangersofthecommonloop.Isolationbetweenthetwotrainsismaintainedbyvalves1/2RRI041VNand1/2RRI058VN(trainA)orbyvalves1/2RRI040VNand1/2RRI059VN(trainB).Thechangeovertothestandbytrainfromanoperatingtraincanbeautomaticormanual.Duringmanualchangeover,thesecondtrainisstarted(switchovervalvesopenedandpumpsstartedup)beforethefailedtrainisstoppedtoavoidsignificantlossofRRIflow.TheswitchovertakesplaceautomaticallyincaseoflowpressureattheRRIpumpoutlet
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年来凤县中小学幼儿园教师招聘笔试备考试题及答案解析
- 【招聘】南丰县总医院人民医院分院公开招聘3名临床医师考试备考题库及答案详解
- 2026河北承德围场满族蒙古族自治县招聘公益性岗位30人考试备考题库及答案详解
- 2026厦门市集美区銮江实验幼儿园非在编教职工招聘3人考试备考试题及答案详解
- 2026年志愿者沟通技巧与心理调适习题集
- 2026年幼儿艺术创造力测试卷
- 2026年心理健康知识与应用测试卷
- 2026年教师资格证考试综合素质专项训练题库
- 2026年岫岩满族自治县事业单位面向 师范类院校应届毕业生校园招聘聘用笔试模拟试题及答案详解
- 2026年金融法规与监管综合测试
- 2026年秋季开学幼儿园秋季传染病防控课件
- 北京市房山区卫生健康委员会所属事业单位招聘笔试真题2025
- 2026年部编版新教材道德与法治四年级上册全册教案设计(共4个单元含教学计划)
- 重卡超级充电站场站布局设计
- 国家能源集团《火力发电工程建设安全标准化图册》
- 吉利汽车GEELY+品牌VI手册 Geely Auto Communication Guidelines (New Energy 2025)
- 护理带教与患者安全
- 钧达股份光伏电池龙头开拓航天新版图
- 江苏省徐州市区2025-2026学年五年级下学期数学期末试题一(试卷+答案)
- 膝关节韧带损伤护理指南
- 2026年兴业证券港股通测试题和答案
评论
0/150
提交评论