发泡陶瓷保温板的主要性能指标发泡陶瓷保温板的主要性能指标应满足表3.1的要求。表3.1 “康卫一方”发泡陶瓷保温板主要性能指标江苏省康斯维信建筑节能技术有限公司(江苏省建筑节能技术中心)序号项目单位性能指标备注1干密度kg/m32802导热系数W/(mK)0.080.10修正系数1.13蓄热系数W/(m2K)1.40计算指标4抗拉强度MPa0.255吸水率(V/V)%86燃烧性能-A级7定压比热J/(KgK)1050特点绿色、防火、保温、防水、防腐、耐久;与建筑同寿命!3.2 发泡陶瓷保温板外墙外保温系统的热工设计指标 发泡陶瓷保温板外墙外保温系统的热工设计指标应按表3.2要求取值。表3.2 发泡陶瓷保温板外墙外保温系统的热工设计指标保温层厚度(mm)基层墙体R0/D钢筋混凝土KP1砖KM1砖混凝土单排孔砌块混凝土双排孔砌块页岩模数砖灰砂砖炉渣砖蒸压粉煤灰砖h=200mmh=240mmh=190mmh=190mmh=190mmh=240mmh=240mmh=240mmh=240mml=1.74l=0.58l=0.58l=1.02l=0.68l=0.45l=1.10l=0.81l=0.6225R00.530.830.750.600.690.950.640.710.80D2.814.113.431.932.512.753.613.924.2030R00.580.880.790.650.740.990.680.760.85D2.894.193.512.012.592.833.694.004.2835R00.620.920.830.690.791.040.720.810.89D2.974.273.592.092.672.913.774.084.3640R00.670.970.880.740.831.090.770.850.94D3.054.353.672.172.752.993.854.164.4445R00.711.010.930.780.881.140.810.890.98D3.134.433.752.252.833.073.924.244.5250R00.761.050.970.830.931.180.860.941.03D3.214.513.832.332.913.154.014.324.6055R00.811.101.020.880.971.220.910.981.08D3.294.593.912.412.993.234.094.404.6860R00.851.151.060.921.011.270.951.031.12D3.374.673.992.493.073.314.174.484.7670R00.941.231.151.011.111.351.041.121.22D3.534.834.152.653.233.474.334.644.9280R01.031.331.251.101.191.451.141.221.30D3.694.994.312.813.393.634.494.805.08注:1、当采用不同导热系数的陶瓷保温板时,厚度应换算。 2、计算时,外墙内饰面混合砂浆按20mm厚考虑,抹面砂浆按10mm厚考虑,粘贴砂浆按5mm厚考虑,当采用不同做法时,应换算。3、传热阻R0= R混合砂浆20厚+ R基层墙体 + R陶瓷保温板+ R水泥砂浆15厚+R内外表面换热阻,热惰性指标D= D混合砂浆20厚+ D基层墙体 + D陶瓷保温板+ D水泥砂浆15厚。4、保温材料导热系数和蓄热系数的修正系数取1.10。3.3 发泡陶瓷保温板防火隔离带的热工设计指标发泡陶瓷保温板防火隔离带的热工设计指标应按表3.3要求取值。表3.3 发泡陶瓷保温板防火隔离带的热工设计指标保温层厚度(mm)基层墙体R0/D钢筋混凝土KP1砖KM1砖混凝土单排孔砌块混凝土双排孔砌块页岩模数砖灰砂砖炉渣砖蒸压粉煤灰砖h=200mmh=240mmh=190mmh=190mmh=190mmh=240mmh=240mmh=240mmh=240mml=1.74l=0.58l=0.58l=1.02l=0.68l=0.45l=1.10l=0.81l=0.6225R00.530.830.750.600.690.950.640.710.80D2.814.113.431.932.512.753.613.924.2030R00.580.880.790.650.740.990.680.760.85D2.894.193.512.012.592.833.694.004.2835R00.620.920.830.690.791.040.720.810.89D2.974.273.592.092.672.913.774.084.3640R00.670.970.880.740.831.090.770.850.94D3.054.353.672.172.752.993.854.164.4445R00.711.010.930.780.881.140.810.890.98D3.134.433.752.252.833.073.924.244.5250R00.761.050.970.830.931.180.860.941.03D3.214.513.832.332.913.154.014.324.6055R00.811.101.020.880.971.220.910.981.08D3.294.593.912.412.993.234.094.404.6860R00.851.151.060.921.011.270.951.031.12D3.374.673.992.493.073.314.174.484.7670R00.941.231.151.011.111.351.041.121.22D3.534.834.152.653.233.474.334.644.9280R01.031.331.251.101.191.451.141.221.30D3.694.994.312.813.393.634.494.805.08注:1、当采用不同导热系数的陶瓷保温板时,厚度应换算。 2、计算时,防火隔离带内饰面混合砂浆按20mm厚考虑,抹面砂浆按10mm厚考虑,粘贴砂浆按5mm厚考虑,当采用不同做法时,应换算。3、防火隔离带的传热阻RF= R混合砂浆20厚+ R基层墙体 + R陶瓷保温板+ R水泥砂浆15厚+R内外表面换热阻,热惰性指标D= D混合砂浆20厚+ D基层墙体 + D陶瓷保温板+ D水泥砂浆15厚,且满足R00.52。4、保温材料导热系数和蓄热系数的修正系数取1.10。5、外墙平均传热阻Rm按照面积加权法进行计算: ,式中: RF-防火隔离带的传热阻; RP外

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论