版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、目 录Directory一、施工地点:Job location1二、参照标准: Basis of compiling1三、材料标准:Material streamlined specification1(一)钢管:Steel pipe1(二)扣件:Fastener1(三)脚手板:Scaffold board2(四)安全网:Protecting net2四、施工工艺:Construction technique2(一)施工准备:Preparations for construction2(二)脚手架搭设的要求:Requirement of scaffold3A、立杆构造要求:Vertical4B
2、、纵向水平杆的构造要求:Longitudinal horizontal bracing4C、横向水平杆的构造要求:Transverse horizontal bracing5D、脚手板的设置:Scaffold board laying5E、剪刀撑:X-bracing6F、扣件:Fastener6(三)脚手架的使用:Requirement of use the scaffold6(四)脚手架的拆除:Demolition the scaffold7五、注意事项:Notice proceeding7 一、施工地点:Job location*化工区工业气体二期管道设备保温工程* caojing HYC
3、O1 STEP-2 insulation project 二、参照标准: Basis of compilingJGJ130-2001 建筑施工扣件式钢管脚手架安全技术规范Steel pipe scaffold safety code of building construction with the fastener三、材料标准:Material streamlined specification(一)钢管:Steel pipe1、脚手架钢管采用外径48mm,壁厚3.5mm,横向水平杆2200mm,其他杆6500mm,每根钢管不应大于25kg。2、钢管表面应平直光滑,不应有裂缝、结疤、分层、错
4、位、硬弯、毛刺、压痕和深的划道。3、钢管的外径、壁厚、端面等的偏差,应分别符合建筑施工扣件式钢管脚手架安全技术规范(JGJ130-2001)的有关规定。1.The external diameter of the steel pipe is 48mm, and thickness of pipe wall is 3.5mm. Transverse horizontal bracing shall be less than 2200mm,others less than 6500mm,and every steel pipe shall be less than 25kg.2.The surfa
5、ce of the steel pipe shall be smoothness, and has not the crack, dogs ear, delaminating, burr and deep nick etc.3.The deviation of the steel pipe, as the external diameter, thickness of pipe wall, port etc, shall be accord the code Steel pipe scaffold safety code of building construction with the fa
6、stener(二)扣件:Fastener1、扣件采用48型。扣件的类型包括:直角扣件、旋转扣件、对接扣件、防滑扣件。2、脚手架采用的扣件,其材质应符合国家现行标准。1.Fastener adopt the type of 48,and the types include the right-angle, circumgyrate, butt joint, and slip-resistance.2.The fastener of the scaffold shall be accord the GB code.(三)脚手板:Scaffold board1、脚手板采用木质,每块质量不宜大于30k
7、g。2、木脚手板应采用杉木或松木制作,其材质应符合国家现行标准。3、脚手板的宽度不宜小于200mm,厚度不应小于50mm,两端应各设直径4mm的镀锌铁丝绑扎两道。1.Every scaffolds quality shall be less than 30kg.2.Scaffold board shall be make of the fir or deal, and accord the GB code.3.The width of the scaffold board shall be over 200mm and thickness over 50mm. On the ends with
8、 the 4mm galvanized wire fixing the board.(四)安全网:Protecting net在脚手架施工操作面和护栏四周围上防护网。It shall be laying safety netting on the operating platform and protecting fence.四、施工工艺:Construction technique(一)施工准备:Preparations for construction1、工程负责人应按施工组织设计中有关脚手架的要求,向架设和使用人员进行技术交底。2、应对所有进场材料按规范进行验收,不合格产品不得使用。3、
9、经检验合格的构配件应按品种、规格分类、堆放整齐、平稳,堆放场地不得有积水。4、当脚手架基础下有设备基础、管沟时,必须采取加固措施。1.The project manager shall be show the regulations for technical operation on the operation worker, about scaffold in this scheme.2.All the material must be check and acceptance, and no qualification no use.3.The qualification materia
10、l shall be stack-up regularity and firmness. The place shall be no water.4.When it has equipment foundation, pipe duct under the base of scaffold, it must to be consolidation.(二)脚手架搭设的要求:Requirement of scaffold1、所搭设的脚手架要坚固、稳定,保证在施工期内及各种载荷和气候条件下不产生变形,不倾斜、不摇晃,安全可靠。2、根据搭设空间,选用适宜的脚手架钢管长度。必须有足够的空间,满足操作、材
11、料堆放及行人的要求。3、脚手架的搭设宽度根据构造要求不能小于1-1.3m,作业层大横杆间隔La/2m,小横杆间隔不能大于纵距的1/2,立杆横距不能大于1-1.3m,立杆纵距不能大于1.5-2.0m。4、K201-K202整体脚手架重大约16T,搭设面长10.3米宽4.6米高度30米,搭设时层面和作业平台连接.支撑以减少整体负荷, 施工人员上下可利用原有设施,作业平台和施工平面须使用梯子上下。1.The scaffold must be firmness, steadiness. During the useful time, it must be no deformation, no incl
12、ination, no sway and safety on the kind of load and climate.2.The pipe of the scaffold must be select the suitable length by the building space, and the space must be enough to suitable for operate, material stack-up and passage.3.The width of the scaffold shall be more than 1-1.3m. In the operating
13、 lay, the big traverse bar shall be distance La/2m, and the small traverse bar shall be less than 1/2 of longitudinal distance. The traverse distance of vertical shall be less than 1-1.3m, and longitudinal less than 1.5-2.0m.4.The scaffold weight of the equipment K201-K202 is about 16T,length about
14、10.3m, width 4.6m, and height about 30m. When its building, the operating lay join the platform to reduce the load. The worker may be use the device, when they up and down, but on operating lay must be use the ladder.A、立杆构造要求:Vertical1、脚手架必须调协纵、横向扫地杆。纵向扫地杆应用直角扣件固定在距底座上皮不大于200mm处的立杆上,横向扫地杆应用直角扣件固定在紧靠
15、纵向扫地杆下方的立杆上。2、当立杆基础不在同一高度上时,必须较高处的纵向杆向低处延长,与立杆固定,高低差不应大于1m。3、立杆接长除顶层顶步可采用搭接外,其余各层各步接头必须采用对接扣件连接。1.When the scaffold build, it shall be harmonize the vertically and horizontally pipe. The vertically pipe shall be fix the base with the right-angle fastener and less than 200mm. The horizontally pipe sh
16、all be fix under the vertically pipe tightly with the right-angle fastener.2.When the vertical base is not on the same plane, it shall be extend from highness to lowness, and the gap shall be less than 1m.3.When the vertical join each other, it must be use the butt joint fastener, but the top.B、纵向水平
17、杆的构造要求:Longitudinal horizontal bracing1、纵向水平杆宜设置在立杆内侧,其长度不宜小于3跨。2、纵向水平杆接长宜采用对接扣件连接,也可采用搭接。3、当使用木脚手板时,纵向水平杆应作为横向水平杆的支座,用直角扣件固定在立杆上。1.Longitudinal horizontal bracing shall be inside the vertical and length shall be more than 3 span.2.Longitudinal horizontal bracing may be use the butt joint or lap joi
18、nt with the fastener.3.When use the scaffold board, longitudinal horizontal bracing is the base of the transverse horizontal bracing, and fix the vertical with the right-angle fastener.C、横向水平杆的构造要求:Transverse horizontal bracing1、主节点处必须设置一根横向水平杆,用直角扣件扣紧且严禁拆除。2、主节点处两个直角扣件的中心距不应大于150mm。3、作业层上非主节点处的横向水平
19、杆,宜根据支承脚手板的需要等间距设置,最大间距不应大于纵距的1/2。1.The central node must be set one transverse horizontal bracing and forbid backout.2.The two right-angle fastener of the central node shall be less than 150mm each other.3.The transverse horizontal bracing of the other node on the operating lay which is not the cen
20、tral, shall be set base on needs, and the max distance shall be less than 1/2 of the longitudinal.D、脚手板的设置:Scaffold board laying1、作业层的脚手板应铺满、铺稳。2、脚手板应设置在三根横向水平杆上。当脚手板的长度小于2m时,可采用两根横向水平杆支承,但应将脚手板两端与其可靠固定,严防倾翻。3、脚手板可采用对接平铺或搭接铺设。4、作业层上端部脚手板探头长度应取150mm,其板长度两端均应与支承杆可靠固定,可用直径3.2mm的镀锌铁丝固定在支承杆杆上。1.The scaff
21、old board of the operating lay shall be pave the all and fixedness.2.The scaffold board shall be lay on three transverse horizontal bracing, when length less than 2m, it may be use the two, but must fix on the ends.3.The scaffold board may be butt joint or lap joint.4.The ends of the scaffold board
22、on the operating lay shall be overstep about 150mm and fix it on the knighthead with the 3.2mm galvanized wire.E、剪刀撑:X-bracing1、脚手架的两端、转角处及每隔5-7个立杆必须设剪刀撑,并由底至顶连续设置,斜杆与地面的夹角为45°-60°,中间各道剪刀撑之间的净距不应大于15mm。2、剪刀撑斜杆的接长宜采用搭接。1.The scaffold must set the X-bracing on the ends, turns and alternation
23、 5-7 vertical. It must be from bottom to top. The diagonals angle is 45-60°to the ground. Each X-bracing distance shall be less than 15mm.2.The distance of X-bracing shall be use the lap joint.F、扣件:Fastener1、扣件规格必须与钢管外径相同。2、对接扣件开口应向上或向内。3、各杆件端头伸出扣件盖板边缘的长度不应小于100mm。1.The spec of fastener must be
24、 same as the external diameter of pipe.2.The open of butt joint fastener shall be up or entad.3.The length shall be more than 100mm, which overstep the fastener on the ends of pipe.(三)脚手架的使用:Requirement of use the scaffold1、没有经过验收的脚手架一律严禁使用。2、脚手架使用前,必须认真检查脚手架是否完好、牢固,如有异常应立即提出整改,合格后方能使用。3、应定期检查安全防护措施
25、是否符合要求,扣件螺栓是否松动及是否超载等。1.The scaffold must be check and acceptance.2.Before use the scaffold, it must to checked. If it has abnormity, it must to refit.3.It must check the means of safety termly, and must be up to the mustard.(四)脚手架的拆除:Demolition the scaffold1、应根据现场情况及业主要求,及时进行脚手架的拆除工作。2、脚手架拆除前,应清除脚手
26、架上杂物及地面障碍物。3、拆除作业应由上而下逐层进行,严禁上下同时作业。4、拆下的脚手架材料应及时运走,不乱堆乱放。5、拆除后,应及时对现场清理,保持场地清洁。1.It shall be dismantle the scaffold in time, by the requirement of the owner and case of the locale.2.Before dismantle the scaffold, it must be clean the sundries on scaffold and the abattis on the ground.3.Dismantle the scaffold shall be from up to down. Prohibit labour at one time.4.The material which is dismantle shall be carry out in time.5.After finish, it shall be cl
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 离子膜电解考核制度
- 综掘队班组考核制度
- 环境质量 考核制度
- 乘车规定及考核制度
- 新媒体技术考核制度
- 技术支持部考核制度
- 送水司机考核制度
- 大学自管会考核制度
- 网格员考评考核制度
- 医院对物业考核制度
- 十字相乘法因式分解专项练习200题及答案
- 中建技术总工(技术负责人)竞聘报告
- DLT 573-2021电力变压器检修导则-PDF解密
- 《浙江省安装工程预算定额》(2010版)
- 东方铸造行业分析
- 财务会计核算制度范本
- 在C51单片机上对读写卡芯片MFRC522编程
- 《西游记》电子版阅读-小学版
- 2024年全年日历表带农历(A4可编辑可直接打印)预留备注位置 精心整理
- TISCO二期扩建工程项目总承包(EPC)合同 中英文
- 磷酸钠安全周知卡、职业危害告知卡、理化特性表
评论
0/150
提交评论