SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格
收藏
资源目录
压缩包内文档预览:
编号:16201702
类型:共享资源
大小:1.29MB
格式:RAR
上传时间:2019-03-12
上传人:hon****an
认证信息
个人认证
丁**(实名认证)
江苏
IP属地:江苏
2.4
积分
- 关 键 词:
-
3503-2007
石油化工建设工程项目交工技术文件规定
石油化工建设工程项目交工技术文
3503-2007石油化工建设工程项目交工技术
SH3503-2007
- 资源描述:
-
SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格,3503-2007,石油化工建设工程项目交工技术文件规定,石油化工建设工程项目交工技术文,3503-2007石油化工建设工程项目交工技术,SH3503-2007
- 内容简介:
-
SH 3503J545火灾报警系统安装检查记录Fire Alarming System Installation Inspection Record工程名称 Project description: 单元名称 Unit description:名称Description图号Drawing No执行标准StandardGB5016692检查内容Inspection contents检查结果Results报警控制器(盘)、探测器、报警按钮、控制设备等设备铭牌与设计相符Alarming controllers (panels), detectors, alarming push buttons, and control equipment etc., should comply with design.导线、电缆的型号、规格与设计相符Wires, cables types, and specifications should comply with design.管路及线槽安装牢固,支吊架位置及间距符合规范要求Conduits and raceways should be secured firmly. The positions for and distances among supports and hangers should comply with code requirements.系统、电压等级、电流类别不同的线路,未穿在同一管内或槽孔中Cable lines for different systems, voltage classes, current types are not installed in the same conduit or slot.检查接线盒内的接线牢靠,绝缘良好Check that the wiring inside the junction box is securely fixed with good insulation.测量线路的绝缘电阻,按回路填写于J543中Measure the insulation resistance of the lines and fill in Table J543 by circuits.检查防爆、防护密封符合规范要求Check that explosion-proof and protection sealing satisfy the requirements of relevant code.探测器、报警按钮、控制设备安装牢固,位置、标高符合设计和规范要求Detectors, alarming push buttons, control equipment should be securely installed. Their positions and elevations should comply with the design and code requirements.9报警控制器(盘)安装牢固,配线整齐,端头标号清晰正确,接地牢靠Alarming controllers (panels) should be securely installed. Wiring arrangement should be neat. End identification marks of the wires should be clear and correct. Grounding should be firmly secured.10核对系统线路,主电源和备用电源自动转换正确可靠Check that system cabling, main power supply and backup power supply and automatic switchover are correct and reliable. 11通电检查报警控制器(盘)的各项功能符合规范和设计要求Power on and check that various functions of the alarming controllers (panels) comply with code and design requirements.12用专用检查仪器对探测器、报警按钮逐个试验,其动作应准确无误Test the detectors and alarming push buttons one by one with special instruments to make sure that their actions are accurate.13分别用主电源和备用电源检查报警系统的各项控制、联动功能正确可靠Check, with main power supply and backup power supply respectively, that various controls and interlock functions are correct and reliable.自年月日时至年月日时系统连续运行120h无故障From Y M D H To Y M D H, system continuously operates 120h without failure.结论 Conclusion备注 Remark建设/监理单位Owner / Supervision Unit施工单位Construction Unit 专业工程师 Discipline Engineer: 年 月
- 温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。