J622.DOC

SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格

收藏

资源目录
跳过导航链接。
SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格.rar
SH 3503-2007 石油化工建设工程项目交工技术文件规定 中英文对照表格
1 Petrochemical - Integrated & General
2 Petrochemical - Building Engineering
3 Petrochemical - Equipment
4 Petrochemical - Piping
5 Petrochemical - Electrical
6 Petrochemical - Instrument
压缩包内文档预览:
预览图
编号:16201702    类型:共享资源    大小:1.29MB    格式:RAR    上传时间:2019-03-12 上传人:hon****an IP属地:江苏
2.4
积分
关 键 词:
3503-2007 石油化工建设工程项目交工技术文件规定 石油化工建设工程项目交工技术文 3503-2007石油化工建设工程项目交工技术 SH3503-2007
资源描述:
SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格,3503-2007,石油化工建设工程项目交工技术文件规定,石油化工建设工程项目交工技术文,3503-2007石油化工建设工程项目交工技术,SH3503-2007
内容简介:
SH 3503J622主电缆安装检查记录Installation Inspection Record of Main Cables工程名称:Project Description:单元名称:Name of BuildingUnit Description:检查项目Item of Inspection检查结果Inspection Result检查日期Inspection Date备注Remark1电缆型号、规格符合设计要求,保护层无破损,电缆导通及绝缘电阻合格Type and specification of cable is in conformity with the design, no damage on protection layer, and cable conductivity and insulation resistance is ok.2不同信号、不同电压等级的电缆在汇线槽内分区(E区、I区、S区)敷设,在架桥上分层敷设Cables with different signal and voltage are laid in different sections (section E, section I and section S) of raceway, and are laid separately in layers on the cable tray.3明敷设的信号电缆与强电磁场电器设备的间距大于1.5m,穿保护管或在汇线槽内敷设时其间距大于800mmDistance between uncovered signaling cable and electrical equipments with strong electromagnetic fields should be more than 1.5m, and when cable run across protection pipe or is laid in raceway, the distance should be more than 800mm.4电缆与工艺设备、管道走向、管道隔热层表面的间距大于200mmDistance of cable from process equipments, pipe route and pipe insulation layer should be more than 200mm.5电缆不宜平行敷设在高温、易燃、可燃介质工艺设备、管道的上方和具有腐蚀性介质、油脂类介质设备、管道的下方It is not appropriate to place cable in parallel above the process equipment, pipes with high temperature, combustible and inflammable medium or , or below equipments and pipes with erosion or oily medium.6电缆排列合理、整齐、美观 Array of cable is reasonable, neat and proper.7电缆的弯曲半径符合规范要求Curving radius of cable is in accordance with standards.8在桥架、垂直汇线槽、DCS机柜、仪表柜内敷设电缆的已固定且松紧适度Cables in cable tray, vertical raceway, DCS cabinet and instrument cabinet are fixed and in proper tension.9电缆终端头已用绝缘胶带包扎、密封,在潮湿、油污场所应涂环氧树脂Cable terminal is bound up and sealed by insulation sellotape, and should be coated with epoxy resin when placed in humid and oil slicked sites.10电缆及芯线的标志牌符合设计要求Tags of cable and cord is in accordance with design.11信号回路的负端在控制室一侧已做工作接地Negative end of signal circuit is earthed for operation at one side of controlling room.12电缆的屏蔽层在控制室一侧已做屏蔽接地,引出的屏蔽线有塑料护套The cable shielding layer has been grounded at one side of control room, and there is plastic sleeve on shield connection wire.13铠装电缆的铠层已在接线盒处做安全接地Covering layer of armored cable is earthed in the terminal box.14电缆在两端、拐弯、伸缩缝、热补偿区段、易震部位均留有裕度Extra length is reserved in ends, corners, flexible clearance, thermo compensation section and vibrating position.15有中间接头的电缆芯线焊接或压接合格,外包高压绝缘胶带,挂标志牌,并在隐蔽工程记录中标明位置Welding or pressing of cable cord with middle joint has passed quality inspection, covered by high voltage insulation sellotape, with tags, and its location is indicated in record of covered projects.注:主电缆指就地接线盒至控制室之间的电缆。 Remark: Main cable refers to cable between earthing wiring box and controlling room.建设 / 监理单位Owner/Supervision Unit施工单位Const
温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
提示  人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
关于本文
本文标题:SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格
链接地址:https://www.renrendoc.com/p-16201702.html

官方联系方式

2:不支持迅雷下载,请使用浏览器下载   
3:不支持QQ浏览器下载,请用其他浏览器   
4:下载后的文档和图纸-无水印   
5:文档经过压缩,下载后原文更清晰   
关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

网站客服QQ:2881952447     

copyright@ 2020-2025  renrendoc.com 人人文库版权所有   联系电话:400-852-1180

备案号:蜀ICP备2022000484号-2       经营许可证: 川B2-20220663       公网安备川公网安备: 51019002004831号

本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知人人文库网,我们立即给予删除!