SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格
收藏
资源目录
压缩包内文档预览:
编号:16201702
类型:共享资源
大小:1.29MB
格式:RAR
上传时间:2019-03-12
上传人:hon****an
认证信息
个人认证
丁**(实名认证)
江苏
IP属地:江苏
2.4
积分
- 关 键 词:
-
3503-2007
石油化工建设工程项目交工技术文件规定
石油化工建设工程项目交工技术文
3503-2007石油化工建设工程项目交工技术
SH3503-2007
- 资源描述:
-
SH3503-2007石油化工建设工程项目交工技术文件规定中英文对照表格,3503-2007,石油化工建设工程项目交工技术文件规定,石油化工建设工程项目交工技术文,3503-2007石油化工建设工程项目交工技术,SH3503-2007
- 内容简介:
-
SH 3503J617DCS机柜、仪表盘、操作台安装检查记录Installation Inspection Record of DCS Cabinets, Instrument Panels and Operation Consoles 工程名称:Project Description: 单元名称:Unit Description: 名称Name型号Type位号Tag No检 查 项 目Item of Inspection检查结果Result of Inspection检查日期Inspection Date备 注Remark1外观无破损、无变形,内外表面无油漆脱落、无受潮、锈蚀等缺陷No visual damage or deformsand no paint ripoff, no humidity and rusting on inner and outer surface.2基础型钢平直、牢靠,外形尺寸与机柜、仪表盘、操作台的尺寸一致,表层除锈防腐Foundation H steel is flat and firm, visual size is in accordance with that of cabinets, instrument panel and operation consoles, and surface is rust-proofing erosion-proofing.3机柜、盘、台的安装布置、铭牌、型号、位号、数量、外形尺寸、仪表开孔尺寸符合设计要求Installation and position of cabinets, panel and consoles, label, type, tag number, quantity, dimension and hole size of instrument are in conformity with the design.4仪表、DCS内部组件的型号、规格、数量、安装位置符合设计要求,无破损、松动、脱落Type, specification, quantity and installation site of instruments and interior components in DCS are in conformity with the design, and no damage, looseness or falling apart exists.5DCS机柜、仪表盘、操作台的垂直度、水平度、盘间接缝间隙、顶部高差、正面平面度符合规范要求,与基础型钢之间采用防锈螺栓牢固连接Verticality, levelness, clearance between panels, height difference on top and front flatness of DCS container, instrument panel and operation desk are in conformity with the design, and foundation structural steel is fixed by rust-proofing bolt.6盘间电缆(含专用电缆)的型号、规格、数量,电缆头、标志牌制做及接线(含内部接线)正确、牢靠、整齐、美观、齐全,符合设计、规范要求Type, specification and quantity, connector and typeof cable (including special cable), and wire connection (including inner wire) are correct, firm, orderly, good-looking, complete, and are in conformity with design and regulation.7机柜、仪表盘、操作台及室内地板下、电缆沟内无尘埃、异物,电缆出、入口应封闭No dust or foreign object exists in machine container, instrument panel, operation desk, underground and cable ditch, and the entrance and exit of cable should be sealed.8电缆(线)的导通、绝缘电阻符合规范要求Conductivity and insulation resistence of cable or wire are in conformity with standards.9就地仪表盘安装在光线充足,环境干燥、操作维修方便的地方,且有良好的密封性Local instrument panel is installed in place with abundant light, dry environment, convenient for operation and maintenance, and with excellent sealing.10电源系统符合设计、规范要求Power system is in conformity with requirements of design and standard.11工作接地系统符合设计、规范要求Earthing system is in conformity with requirements of design and standard.12保护接地系统符合设计、规范要求Protection earthing system is in conformity with requirements of design and standard.13屏蔽接地系统符合设计、规范要求Shielding earthing system is in conformity with requirements of design and standard.14随盘技术文件应齐全Technical documents together with instrument are complete.备注:Remark:建 设 / 监 理 单 位Owner/Supervision Unit施 工 单 位Constru
- 温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。